1. Home /
  2. FSC NSN Catalog /
  3. Circuit Breakers /
  4. 5925-00-004-6994

NSN 5925-00-004-6994

Circuit Breaker

A cap designed to mate with a fluid valve body. It may have an orifice through which a rod, shaft, stem, or an adjusting screw passes. For ported items, see head, valve. Excludes:cap, pneumatic valve.

single pole type body style, at pole one actuator position designation, trip-reset actuator function, 1.137 inches nominal body length, 0.750 inches nominal body width.

NSN 5925-00-004-6994 Datasheet

(NSN) National Stock Number
5925-00-004-6994
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
00-004-6994
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Wed, Jun 7, 1972
Schedule B Code
8536200040
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Body Length
1.137 inches nominal
Body Style
single pole type
Body Width
0.750 inches nominal
Bushing Length
0.250 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.650 inches nominal
Circuit Protection Type
overcurrent single location
Frequency In Hertz
400.0 single location
Internal Trip Release Configuration
series trip single location
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Material
plastic case
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac and 1.0 amperes dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac and 60000.0 dc single location
Mounting Facility Type And Quantity
1 threaded bushing
Mounting Surface To Terminal End Distance
1.812 inches nominal
Nominal Thread Size
0.469 inches
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac and 30.0 dc single location
Pole Quantity
1
Reset Method
manual
Terminal Type And Quantity
2 screw
Thread Quantity Per Inch
32
Thread Series Designator
unified national coarse (unc)
Trip Release Ambient Temp Rating
200.0 fahrenheit maximum single location
Trip Release Characteristic
time delay single location
Trip Release Method
thermal single location
Trip Delay Time In Seconds Per Rated Continuous Current
0.400 minimum at 200 pct and 2.000 maximum at 200 pct single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Ultimate Trip Time Per Pole In Seconds
5.000 nominal single location

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

10001
Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier
U.s./canadian manufacturers
76374
Safran Electrical & Power Usa, Llc Dba Labinal Power Sysyems Use Cage Code 81640 for Cataloging
U.s./canadian manufacturers
81640
Safran Power Usa, Llc
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-00-004-6994?

    The FSCG of the NSN 5925-00-004-6994 is 5925

  2. Does the NSN 5925-00-004-6994 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-00-004-6994 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-00-004-6994 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5925-00-004-6994 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-00-004-6994 was assigned to the Federal Catalog?

    It was assigned 54 years ago, on Wed, Jun 7, 1972

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.