Secure Ordering: +1 (757) 528-8028
NationalStockNumber.info
NationalStockNumber.INFO

Worldwide distributor of NSN parts and consumables located in the USA.

Circuit Breaker

NSN: 5925-00-005-3114 | Model: MCP331000R

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating elemen (s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified) ; and controller.

Description

Unthreaded mounting hole diameter: 0.187", maximum continuous load current rating per pole: 100 amperes ac all locations

NSN Properties and Flags
NATO Stock Number
5925-00-005-3114
DEMIL
NO
Body Style
Multipole-single actuator type
Body Length
6 inches
Body Width
4.125 inches
Body Height
3.375 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
5.062 inches
Center To Center Distance Between Terminals Parallel To Width
1.375 inches
Unthreaded Mounting Hole Diameter
0.187 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.5 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches
Fragility Factor
Moderately rugged
Boss Height
0.125 inches
Pole Quantity
3
Mounting Facility Type and Quantity
4 unthreaded hole
Storage Type
General purpose warehouse
Maximum Continuous Load Current Rating Per Pole
100 amperes ac all locations
Operating Voltage Type and Rating Per Pole In Volts
600 ac all locations
Maximum Interrupting Capacity Current Type and Rating Per Pole In Amps
14000 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type and Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole two
Internal Trip Release Configuration
Series trip all locations
Trip Delay Time In Seconds Per Rated Continuous Current
200 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant
Frequency In Hertz
60 all locations
Terminal Type and Quantity
6 compression
Recent Solicitations
Solicitation Return by Date Buyer Code Quantity
SPE7M521T136E 2021-04-22 PMCM5 4 EA

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

NSN 5925-00-005-3114 Datasheet

Supply Class (FSC):
Circuit Breakers
Cross Reference:
  • MCP331000R
  • C528-11
  • 23739
  • 4994D97G27
  • MCP331000
Cage Codes:
  • Eaton Corporation (CAGE 89946)
  • Hamilton Sundstrand Corporation (CAGE 99167)
  • Erie Strayer Company (CAGE 20874)
Schedule B & Trade:
  • Schedule B: 8536200040 (NAICS 335313)

    Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi

  • SITC: 77252

    Automatic circuit breakers for a voltage not exceeding 1, 000 volts

  • End Use: 20005

    Electric apparatus

Identification:
HMIC

P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

PMIC

U - Precious metal content is unknown

CRITL

- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Freight Information:
  • NMFC:

    061300 - Circuit breaker/switch noi

  • WCC:

    658 - Electrical appliances, small

  • SHC:

    9 - Other or no special handling required (sh)

  • ADC:

    A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.

  • ACC:

    H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)

  • LTL:

    P - 77.5

  • TCC:

    Z - No special type of cargo code applicable

NSN Management Codes:
  • SOS
    Sms
  • AAC
    Z
  • Quantity per pack
    1
  • Unit of Measure
    Ea
  • Shelf Life
    N/A
  • Classification Control
    U
  • MGMT_CTL
    Sf9eh-n
  • Repariability

Questions & Answers:

What are the historical prices recorded for this stock number?
Historical data shows pricing from $2,339.08 to $3,898.46..
Does NSN 5925-00-005-3114 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
Department Of The Air Force, Department Of The Navy, and Canada
What is the NIIN of NSN 5925-00-005-3114?
000053114 or 00-005-3114
Does NSN 5925-00-005-3114 require demilitarization?
Yes - ITAR Controlled
What is the most recent solicitation for NSN 5925-00-005-3114?
Solicitation SPE7M521T136E for qty 4 on 04/20/2021
When was this national stock number assigned to the federal catalog?
Jun 14, 1972