NSN 5925-00-005-8912 Circuit Breaker

Manufacturer Part Numbers

Part Number Name Cage Code
403917-1 Circuit Breaker 00752
APG-111-1-42-751-00 Circuit Breaker 81541

Management Codes

CTL: 9B----- (MOE: DN)
SOS: SMS
AAC: Insurance/numeric stockage objective item. items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. the item is central
CIIC:
RC:
QUP: 1
UI: EA
SLC: 0

Freight Codes

NMF Desc: Circuit Breaker/switch Noi
NMFC: 061300
UFC: 34410
LTL: 77.5
LCL:
WCC: Electrical appliances, small
TCC: No special type of cargo code applicable
SHC: Other or no special handling required (sh)
ADC: Shipment is not a consolidation and does not exceed 84 inches in any dimension.
ACC: Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ASH: No special handling required.

Identification

DEMIL Code: A
DEMIL Integ:
ADPE: )
CRITL: X
ENAC:
ESD: )
HMIC: P
Schedule B: 8536200040 – Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
NIIN: 000058912

5925-00-005-8912 Datasheet

Actuator Function: Trip-reset
Actuator Position Designation: At each pole
Body Length: 2.000 inches nominal
Body Style: Multipole-multiple actuator type
Body Width: 2.250 inches nominal
Bushing Length: 0.130 inches nominal
Case Material: Plastic
Center To Center Distance Between Terminals Parallel To Length: 1.530 inches nominal
Center To Center Distance Between Terminals Parallel To Width: 0.750 inches nominal
Circuit Protection Type: Overcurrent all locations
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length: 1.660 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width: 0.750 inches nominal
External Actuator Linkage Arrangement: One, two, and three linked
Frequency In Hertz: 400.0 all locations
Maximum Continuous Load Current Rating Per Pole: 750.0 milliamperes ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps: 1000.0 ac all locations
Mounting Facility Type And Quantity: 6 threaded hole
Mounting Surface To Terminal End Distance: 2.000 inches maximum
Nominal Thread Size: 0.138 inches
Operating Voltage Type And Rating Per Pole In Volts: 250.0 ac all locations
Storage Type: General purpose warehouse
Inclosure Protection Type For Which Designed: Fungus resistant
Internal Trip Release Configuration: Series trip all locations
Main Contact Tripping Mechanism Type: Trip free
Manual Actuator Type And Quantity: 3 toggle
Reset Method: Manual
Pole Quantity: 3
Terminal Type And Quantity: 6 quick disconnect, male
Thread Quantity Per Inch: 32
Thread Series Designator: Unc
Trip Delay Time In Seconds Per Rated Continuous Current: 2.500 minimum at 200 pct all locations and 25.000 maximum at 200 pct all locations
Trip Release Characteristic: Time delay all locations
Trip Release Method: Magnetic-hydraulic all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent: 150.0 all locations

Questions & Answers

What are the historical prices recorded for this stock number?
No pre-dated pricing for this NSN could be found.
What NATO entities are users of this NSN?
No recorded entities for this stock number.
How is national stock number 5925-00-005-8912 categorized?
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does this item require Demilitarization?
Non-usml/non-ccli - no demil or dod tsc required. department of commerce may impose licensing requirements to certain destinations. (note 9).
Is this item ITAR controlled?
No. This item is not ITAR Controlled.
When was this national stock number assigned to the federal catalog?
Jun 19, 1972