S Electrical Insulation Sleeving

SKU: 5970001101060 | Model: SMC604344
NSN 5970-00-110-1060 NSN 5970-00-110-1060
Description:

-50.0 degrees Celsius temp rating, corrosion resistant environmental protection, 0.070" after unrestricted recovery main body wall thickness

Specifications from the Manufacturer

Reliability Indicator:
Not established
Temp Rating:
-50.0 deg celsius
Environmental Protection:
Corrosion resistant and mildew resistant and water resistant
Main Body Inside Diameter:
0.380 inches maximum after unrestricted recovery
Main Body Inside Diameter:
0.760 inches minimum as supplied
First Branch Inside Diameter:
0.210 inches maximum after unrestricted recovery
First Branch Inside Diameter:
0.370 inches minimum as supplied
Second Branch Inside Diameter:
0.210 inches maximum after unrestricted recovery
Second Branch Inside Diameter:
0.370 inches minimum as supplied
Third Branch Inside Diameter:
0.210 inches maximum after unrestricted recovery
Third Branch Inside Diameter:
0.370 inches minimum as supplied
Fourth Branch Inside Diameter:
0.210 inches maximum after unrestricted recovery
Fourth Branch Inside Diameter:
0.370 inches minimum as supplied
Distance From Intersecting Centerline Of Main Body To End Of Second Branch:
1.400 inches nominal after unrestricted recovery
Distance From Intersecting Centerline Of Main Body To End Of First Branch:
1.260 inches nominal after unrestricted recovery
Main Body Wall Thickness:
0.070 inches nominal after unrestricted recovery
First Branch Wall Thickness:
0.040 inches nominal after unrestricted recovery
Second Branch Wall Thickness:
0.040 inches nominal after unrestricted recovery
Third Branch Wall Thickness:
0.040 inches nominal after unrestricted recovery
Fourth Branch Wall Thickness:
0.040 inches nominal after unrestricted recovery
Distance From Edge Of Main Body To Intersecting Centerlines:
1.420 inches nominal after unrestricted recovery
Angle Between Main Body And First Branch Centerlines In Deg:
10.0 nominal after unrestricted recovery
Angle Between Main Body And Second Branch Centerlines In Deg:
15.0 nominal after unrestricted recovery
Minimum Tensile Strength:
1200 pounds per square inch
Flexibility:
Flexible
Color:
Black
Material:
Plastic,polyolefin,rt-1304,raychem corp
Material:
Plastic,polyolefin,rt-1304,raychem corp
Style Designator:
Transition-1 to 4 cables
Dielectric Material Voltage Rating Per Unit Thickness:
225.0 volts per mil /0.001 inch/

Pricing and Availability

Request a Quote

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Quantity:
Company:
Name:
Email:
Phone:

Order With Confidence

Certified quality parts supplier
  • MSDS Hazmat Certified
  • certified Committed to quality with 100% product inspection
  • on time delivery icon On-time delivery
Recently Updated in Electrical Insulators And Insulating Materials

NSN 5970-00-110-1060 Datasheet

Supply Class:

5970 ELECTRICAL INSULATORS AND INSULATING MATERIALS

Cross Reference:

  • SMC604344
  • SMC604344-4
  • 562A022-4

Cage Codes:

  • Us Army Communications & (CAGE 80063)
  • Tyco Electronics Corporation (CAGE 06090)

Replaced or Cancelled:

5970-00-110-1060 replaces the national stock number 5970-00-110-1714

Identification:

NIIN: 001101060
NSN: 5970001101060
DEMIL Code: A
DEMIL Code Meaning: Non-usml/non-ccli - no demil or dod tsc required. department of commerce may impose licensing requirements to certain destinations.
ADPE:
CRITL: X
ENAC:
ESD:
HMIC: P
PMIC: A

Freight Codes:

NMF Desc: Insulating Material Noi
NMFC: 103300
UFC: 53360
LTL: Rating variable
LCL:
WCC: Communications/electronics, other than sigint/ew or comsec repair parts and components
TCC: No special type of cargo code applicable
SHC: Other or no special handling required (sh)
ADC: Shipment is not a consolidation and does not exceed 84 inches in any dimension.
ACC: Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ASH: No special handling required.

Management Codes:

CTL: 9B----- (MOE: DN), ------- (MOE: DS)
SOS: SMS
AAC: Not stocked, centrally procured # (non-stocked items). imm/service centrally managed but not stocked item. procurement will be initiated only after receipt of a requisition.
CIIC:
RC:
QUP: 1
UI: EA
SLC: 0

Reference Drawing:

[drawing of 5970-00-110-1060]

Schedule B & Trade:

8546900000 (NAICS 326199)
Electrical insulators, nesoi
SITC:
77324

Electrical insulators of material other than glass or ceramics

End Use:
20005

Electric apparatus

Questions & Answers:

What are the historical prices recorded for this stock number?
No pre-dated pricing for this NSN could be found.
Does NSN 5970-00-110-1060 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
No recorded entities for this stock number.
How is national stock number 5970-00-110-1060 defined?
A rigid or flexible tubing having other than uniform fabricated shapes or forms. it is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. includes shrinkable type items. excludes items not having rated electrical characteristics. also excludes bushing, sleeve; cable nipple, electrical; and insulation sleeving, electrical.
What is the NIIN of NSN 5970-00-110-1060?
001101060 or 00-110-1060
Does this item require Demilitarization?
Non-usml/non-ccli - no demil or dod tsc required. department of commerce may impose licensing requirements to certain destinations. (note 9).
Is NSN 5970001101060 ITAR controlled?
No. This item is not ITAR Controlled.
What is the most recent solicitation for NSN 5970001101060?
No solicitations for this NSN.
When was this national stock number assigned to the federal catalog?
Sep 16, 1972