Voltmeter

SKU: 6625004582481 | Model: 251-115A
NSN 6625-00-458-2481 NSN 6625-00-458-2481

Specifications from the Manufacturer

Circuit Current For Which Designed:
Ac
Dielectric Withstanding Voltage In Volts:
1500.0
Overall Length:
2.276 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Length:
5.240 inches minimum and 5.260 inches maximum
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.090 inches minimum and 3.010 inches maximum
Overall Height:
4.318 inches minimum and 4.348 inches maximum
Overall Width:
5.602 inches minimum and 5.622 inches maximum
Scale Division Quantity:
101 single indicator 1st range
Scale Division Quantity:
61 single indicator 2nd range
Mounting Stud Length:
0.500 inches nominal
Environmental Protection:
Airtight and dust resistant and fungus resistant and heat resistant and humidity resistant and shock resistant and vibration resistant and water resistant
Furnished Items And Quantity:
Nut 8; lockwasher 6; shunt wire 1; seal 1
Indicator Type:
Dial w/pointer
Installation Design:
Panel
Mounting Arrangement Style:
Four hole/stud rectangular/square
Sensitivity Rating:
100.0 volts
Dial Scale Marking Color:
Black single indicator 1st range
Dial Scale Marking Color:
Red single indicator 3rd range
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator all ranges
Accuracy In Percent:
-2.0 to 2.0 at full scale single indicator all ranges
Meter Depth Behind Mounting Flange:
1.155 inches minimum and 1.165 inches maximum
Meter Body Diameter Behind Mounting Flange:
2.770 inches minimum and 2.790 inches maximum
Movement Type:
Moving coil, permanent magnet
Background Color:
White single indicator all ranges
Pointer Color:
Red single indicator all ranges
Power Source:
External
Mounting Facility Type And Quantity:
4 threaded stud
Scale Graduation Type:
Linear single indicator 1st range
Scale Graduation Type:
Nonlinear single indicator 3rd range
Measurement Range:
+0.0/+10.0 millivolts, ac single indicator 2nd range
Measurement Range:
+0.0 to 50.0 millivolts, ac single indicator 3rd range
Mounting Stud Diameter:
0.128 inches minimum and 0.148 inches maximum
Scale Selection Method:
Terminal
Features Provided:
External shunting and luminous scale marking and magnetic shield and zero adjuster
Movement Suspension Method:
Jewel pivot base
Circuit Attachment Method And Quantity:
2 threaded stud
Special Features:
Ruggedized
Material:
Plastic
Nuclear Hardness Critical Feature:
Nonhardened
Surface Treatment:
Paint
Special Test Features:
Complies with mil-m-10304
Style Designator:
Rectangular flush mtg
FSC Application Data:
Test set,elect. equip.

Pricing and Availability

Request a Quote

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Quantity:
Company:
Name:
Email:
Phone:

Order With Confidence

Certified quality parts supplier
  • MSDS Hazmat Certified
  • certified Committed to quality with 100% product inspection
  • on time delivery icon On-time delivery
Recently Updated in Electrical And Electronic Properties Measuring And Testing Instruments

NSN 6625-00-458-2481 Datasheet

Supply Class:

6625 ELECTRICAL AND ELECTRONIC PROPERTIES MEASURING AND TESTING INSTRUMENTS

Cross Reference:

  • 251-115A
  • 251-1115
  • 203-1115

Cage Codes:

  • Millivac Instruments Inc (CAGE 85711)

Replaced or Cancelled:

6625-00-458-2481 is not a replacement of any national stock number and has not been cancelled or replaced itself.

Identification:

NIIN: 004582481
NSN: 6625004582481
DEMIL Code: A
DEMIL Code Meaning: Non-usml/non-ccli - no demil or dod tsc required. department of commerce may impose licensing requirements to certain destinations.
ADPE: 0 (Represents items with no adp components)
CRITL: X
ENAC:
ESD:
HMIC: P
PMIC: A

Freight Codes:

NMF Desc: Meters Elec/parts
NMFC: 136740
UFC: 68820
LTL: Rating variable
LCL:
WCC: Instruments, electric meter
TCC: No special type of cargo code applicable
SHC: Other or no special handling required (sh)
ADC: Shipment is not a consolidation and does not exceed 84 inches in any dimension.
ACC: Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ASH: No special handling required.

Management Codes:

CTL: SF9TG-N (MOE: DF), ------- (MOE: DS)
SOS: SMS
AAC: Insurance/numeric stockage objective item. items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. the item is central
CIIC:
RC:
QUP: 1
UI: EA
SLC: 0

Reference Drawing:

[drawing of 6625-00-458-2481]

Schedule B & Trade:

9030908030 (NAICS 334515)
Parts and accessories of articles of schedule b subheading 9030.39
SITC:
87479

Parts and accessories for instruments and apparatus (except meters) measuring etc. electrical quanities and devices measuring etc. ionized radiations

End Use:
21160

Measuring, testing, control instruments

Questions & Answers:

What are the historical prices recorded for this stock number?
No pre-dated pricing for this NSN could be found.
Does NSN 6625-00-458-2481 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
Turkey, and United States
How is national stock number 6625-00-458-2481 defined?
An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. the value may be expressed by means of a pointer and calibrated dial or a digital readout display.
What is the NIIN of NSN 6625-00-458-2481?
004582481 or 00-458-2481
Does this item require Demilitarization?
Non-usml/non-ccli - no demil or dod tsc required. department of commerce may impose licensing requirements to certain destinations. (note 9).
Is NSN 6625004582481 ITAR controlled?
No. This item is not ITAR Controlled.
What is the most recent solicitation for NSN 6625004582481?
No solicitations for this NSN.
When was this national stock number assigned to the federal catalog?
Apr 30, 1969