Worldwide distributor of NSN parts and consumables located in the USA.
An electrically charged chemical agent, used in copy processing, which transfers the image from the charged areas of a selenium drum to the recorder paper.
Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.
Chemical preparation for photographic uses & unmixed products for photographic uses, measured/retail sale, ready for use, except sensitizes emulsions
Chemicals prepared for photographic use (except varnish, glue, etc.); unmixed products for photo use in measured portions or ready to use retail packs
Chemicals-other
Y - Indicates information is in the hazardous materials information resource system (hmirs).
PMICA - Item does not contain precious metal.
ENACE4 - Toner cartridges
CRITL- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
043940 - Chemicals noi
635 - Chemicals, other than drugs or sundries
9 - Other or no special handling required (sh)
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
C - Chemical corps items and all other chemicals not covered in other classificatons. note: when an item has a chemical proper shipp
W - Rating variable
Z - No special type of cargo code applicable
Questions & Answers: |
|
What are the historical prices recorded for this stock number? | |
Historical data shows pricing from $154.91 to $258.19.. | |
Does NSN 6850-01-357-9991 have a shelf life? | |
No. There is no shelf life applicable for this NSN. | |
What NATO entities are users of this NSN? | |
Department Of The Air Force, U.s. Marine Corps, Department Of The Navy, Federal Aviation Administration, U.s. Coast Guard, Veterans Administration, Spain, Malaysia, Canada, France, Republic Of Korea, United Kingdom, Portugal, Italy, Norway, Greece, Turkey, and Nato Maintenance and Supply Agency | |
What is the NIIN of NSN 6850-01-357-9991? | |
013579991 or 01-357-9991 | |
Does NSN 6850-01-357-9991 require demilitarization? | |
Yes - ITAR Controlled | |
What is the most recent solicitation for NSN 6850-01-357-9991? | |
No solicitations for this NSN. | |
When was this national stock number assigned to the federal catalog? | |
May 06, 1992 |
Ld50 lc50 mixture: none specified by manufacturer.
routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: inhalation: toner is finely divided
solid. Do not breathe dust. Eye: any material that contacts eye may
be irritating. Skin: low hazard for industrial handling.
explanation of carcinogenicity: not relevant.
effects of overexposure: minimal respiratory tract irritation may occur
as with exposure to large amounts of any non toxic dust.
medical cond aggravated by exposure: none specified by manufacturer.
First aid: inhalation: remove from exposure to fresh air. Eye: open eye
and flush with plenty of water for at least 15 minutes. If
irritation persists get medical attention. Skin: wash with soap and
water. Inges tion: drink several glasses of water. Call physician.
Hcc: n1
nrc/state lic num: not relevant
melt/freeze pt: m.P/f.P text: >212f,>100c
vapor pres: negligible
spec gravity: 1.5-1.8(h*2o=1)
viscosity: not relevant
evaporation rate & reference: neglig (butyl acetate=1)
solubility in water: negligible
appearance and odor: fine powder, slight plastic odor.
percent volatiles by volume: neglig
Stability indicator/materials to avoid: yes
strong oxidizers.
stability condition to avoid: none specified by manufacturer.
hazardous decomposition products: as with any other organic material,
decomposition will produce carbon dioxide and carbon monoxide.
Waste disposal methods: no special disposal technique is required.
ensure compliance with federal, state and/or local regulations.
toner may be considered plastic waste. Cartridge is constructed of
plastics and metals.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: styrene acrylate copolymer
fraction by wt: 45-55%
osha pel: n/k
acgih tlv: n/k
ingred name: iron (iii) oxide; (iron oxide)
cas: 1309-37-1
rtecs #: no7400000
fraction by wt: 45-55%
osha pel: 10 mg/m3 (fe)
acgih tlv: 5 mg/m3 (fe)
Ld50 lc50 mixture: ld50 (oral, rat) is not known.
routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: target organs: eyes, skin, respiratory
tract. Acute- toner powder is not accesible, unless the cartridge
is forced, or broken into. Minimal respiratory tract irritation may
occur as with exposure to la rge amounts of any dust. If material
contacts eyes can cause irritation. Chronic- unknown.
explanation of carcinogenicity: none
effects of overexposure: none. Toner powder is not accesible, unless the
cartridge is forced, or broken into. Minimal respiratory tract
irritatio, eye irritation
First aid: get medical help if symptoms persist. Inhaled: remove to fresh
air. Eyes: flush with water for 15 minutes, holding eyelids open.
skin: wash with soap & water. Oral: drink several glasses of water.
call a physician.
Hcc: m1
nrc/state lic num: not relevant
melt/freeze pt: m.P/f.P text: 212f - 302f
vapor pres: negligible
spec gravity: 1.5 - 1.8
viscosity: not relevant
evaporation rate & reference: not relevant
solubility in water: negligible
appearance and odor: magnetized material, fine powder form - slight
plastic odor
percent volatiles by volume: neglig
Stability indicator/materials to avoid: yes
strong oxidizing agents
stability condition to avoid: none
hazardous decomposition products: carbon monoxide, carbon dioxide may be
formed.
Waste disposal methods: dispose of in accordance with all local, state
and federal regulations.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: styrene acrylic copolymer
fraction by wt: 45 - 55%
other rec limits: none recommended
ingred name: iron oxide
cas: 1317-61-9
fraction by wt: 45 - 55%
other rec limits: none recommended
osha pel: 10 mg/m3
acgih tlv: 5 mg/m3
Routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: toner powder is not accessible, until
the cartridge is forced to be broken. Acute: minimal respiratory
tract irritation may occur as w/exposure to large amounts any
non-toxic dust. No data available fo r chronic effects of
overexposure.
explanation of carcinogenicity: manufacturer gave no information about
carcinogenicity. Hmis does not expect it to be carcinogenic.
effects of overexposure: inhalation: toner is finely divided solid. Do
not breathe the dust. Eye: any material that contacts the eye may be
irritating. no specific hazard known to canon. Skin: low hazard for
industrial handling .
medical cond aggravated by exposure: mfr gave no information on msds.
First aid: inhalation: remove from exposure to fresh air. Eye: open eye &
flush w/plenty of water. If irritation persists get medical
attention. Skin: wash w/soap and water. Ingestion: drink several
glasses of water . Call a physician.
Hcc: n1
nrc/state lic num: none
melt/freeze pt: m.P/f.P text: >212f,>100c
vapor pres: negligible
spec gravity: 1.5-1.8
evaporation rate & reference: neglegible (n-buac = 1)
solubility in water: negligible
appearance and odor: fine powder, slight plastic odor
percent volatiles by volume: neglig
Stability indicator/materials to avoid: yes
strong oxidizers.
stability condition to avoid: mfr gave no information on msds.
hazardous decomposition products: as w/any other organic material,
decomposition will produce carbon dioxide and carbon monoxide.
conditions to avoid polymerization: will not occur.
Waste disposal methods: no special disposal technique required. Ensure
compliance with federal, state and/or local regulations. Toner may
be considered plastic waste. Cartridge is constructed of plastics
and metals.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: styrene-acrylic terpolymer
fraction by wt: 45-55%
ingred name: iron oxide
cas: 1317-61-9
fraction by wt: 45-55%
osha pel: 10 mg/m3
acgih tlv: 5 mg/m3
Routes of entry: inhalation: no skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: acute: minimal respiratory tract
irritation may occur as with any exposure to large amounts of any
non-toxic dust. No specific eye hazard is known; however, any
material that contacts the eye may be i rritating. Low hazard for
skin contact during industrial handling. Chronic: none specified by
manufacturer.
explanation of carcinogenicity: no ingredient of a concentration of 0.1%
or greater is listed as a carcinogen or suspected carcinogen.
effects of overexposure: inhaled-minimal irritation, coughing, sneezing.
eyes-possible irritation, tearing, redness.
medical cond aggravated by exposure: none specified by manufacturer.
First aid: inhaled-remove from exposure to fresh air. Eyes-open eye and
flush with plenty of water. If irritation persists get medical
attention. Skin-wash with soap and water. Ingestion-if conscious,
drink seve ral glasses of water. Call a physician.
Hcc: n1
melt/freeze pt: m.P/f.P text: >212f,>100c
vapor pres: negligible
spec gravity: 1.5-1.6
evaporation rate & reference: negligible
solubility in water: negligible
appearance and odor: fine powder; slight plastic odor.
percent volatiles by volume: neg
Stability indicator/materials to avoid: yes
strong oxidizing agents.
stability condition to avoid: none specified by manufacturer.
hazardous decomposition products: as with any other organic material,
decomposition will prodec carbon monoxide and carbon dioxide.
conditions to avoid polymerization: will not occur.
Waste disposal methods: no special disposal technique is required.
ensure compliance with local, state and federal regulations. Toner
may be considered plastic waste. Cartridge is constructed of
plastics and metals.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: iron oxide
cas: 1317-61-9
fraction by wt: 45-55%
other rec limits: none recommended
osha pel: 10 mg/m3
acgih tlv: 5 mg/m3
ingred name: styrene acrylate copolymer,
cas: 25153-46-2
fraction by wt: 46-55%
other rec limits: none recommended
Hcc: n1
spec gravity: 1.0
solubility in water: negligible
appearance and odor: finely divided black powder; faint odor.
Stability indicator/materials to avoid: yes
none specified by manufacturer.
stability condition to avoid: none.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: amorphous silica (silica gel)
cas: 112945-52-5
rtecs #: vv7310000
fraction by wt:
other rec limits: none recommended
osha pel: 6 mg/m3
acgih tlv: 10 mg/m3
ingred name: dyestuff (chromate(1-), [
((5-chloro-2-hydroxy-phenyl)az0)-2-naphtalenolato(2-)]-,hdrogen,)
cas: 31714-55-3
fraction by wt:
other rec limits: none recommended
ingred name: iron oxide
cas: 1309-37-1
rtecs #: no7400000
fraction by wt: 30-50%
other rec limits: none recommended
osha pel: 10 mg/m3 (fe)
acgih tlv: 5mg(fe)/m3fume,b2;95
ingred name: pmma (polymethylmethacrylate)
cas: 9011-14-7
rtecs #: tr0400000
fraction by wt:
other rec limits: none recommended
ingred name: polyolefin (polypropylene)
cas: 9003-07-0
rtecs #: tr5000000
fraction by wt:
other rec limits: none recommended
ingred name: styrene acrylate (manufacturer gave cas# 25757-47-9 which
is invalid)
cas: 67953-61-1
fraction by wt: 40-65%
other rec limits: none recommended
Ld50 lc50 mixture: acgih tlv for nuissance dust is 10mg/m3
routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: acute: inhalation of dust may cause
slight respiratory tract irritation. Eye contact may cause slight
irritation. No known health effects from skin contact . No data
given for ingestion. Chronic: no d ata available for chronic
effects of overexposure.
explanation of carcinogenicity: no ingredient of a concentration of 0.1%
or greater is listed as a carcinogen or suspected carcinogen.
effects of overexposure: inhaled-irritation, coughing, sneezing.
eyes-irritation, tearing, discomfort.
medical cond aggravated by exposure: none specified by manufacturer.
First aid: inhaled-remove from exposure to fresh air. Eyes-lift lids,
flush with lots of water for 15 minutes. Get medical attention if
irritation persists. Skin-wash with soap & water. Ingestion-if
conscious, d rink several glasses of water. Call a physician.
Hcc: m1
melt/freeze pt: m.P/f.P text: >212f,>100c
vapor pres: negligible
spec gravity: 1.5-1.8
evaporation rate & reference: negligible
solubility in water: negligible
appearance and odor: fine powder; slight plastic odor.
percent volatiles by volume: nil
Stability indicator/materials to avoid: yes
strong oxidizing agents.
stability condition to avoid: dusty conditions with sources of ignition.
hazardous decomposition products: carbon monoxide and carbon dioxide.
conditions to avoid polymerization: will not occur.
Waste disposal methods: no special disposal technique is required.
ensure compliance with local, state and federal regulations. Toner
may be considered plastic waste. Cartridge is constructed of
plastic and metals. All compo nents registered iaw tsca.
Ingred name: styrene acrylate copolymer
cas: 25153-46-2
fraction by wt: 45-55%
other rec limits: none recommended
ingred name: iron oxide
cas: 1317-61-9
fraction by wt: 45-55%
other rec limits: none recommended
osha pel: 10 mg/m3
acgih tlv: 5 mg/m3
Ld50 lc50 mixture: none specified by manufacturer.
routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: inhalation: toner is finely divided
solid. Do not breathe dust. Eye: any material that contacts eye may
be irritating. Skin: low hazard for industrial handling.
explanation of carcinogenicity: this compound contains no ingredients at
concentrations of 0.1% or greater that are carcinogens or suspect
carcinogens.
effects of overexposure: minimal respiratory tract irritation may occur
as with exposure to large amounts of any non toxic dust.
medical cond aggravated by exposure: none specified by manufacturer.
First aid: inhalation: remove from exposure to fresh air. Eye: open eye
and flush with plenty of water for at least 15 minutes. If
irritation persists get medical attention. Skin: wash with soap and
water. Inges tion: drink several glasses of water. Call physician.
Hcc: n1
boiling pt: b.P. Text: not given
melt/freeze pt: m.P/f.P text: >212f,>100c
vapor pres: negligible
vapor density: not given
spec gravity: 1.5-1.8
viscosity: not relevant
evaporation rate & reference: negligible
solubility in water: negligible
appearance and odor: fine powder, slight plastic odor.
percent volatiles by volume: nil
Stability indicator/materials to avoid: yes
strong oxidizers.
stability condition to avoid: none specified by manufacturer.
hazardous decomposition products: as with any other organic material,
decomposition will produce carbon dioxide and carbon monoxide.
Waste disposal methods: no special disposal technique is required.
ensure compliance with federal, state and/or local regulations.
toner may be considered plastic waste. Cartridge is constructed of
plastics and metals.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: styrene acrylate copolymer
fraction by wt: 45-55%
other rec limits: none specified
ingred name: iron (iii) oxide; (iron oxide)
cas: 1309-37-1
rtecs #: no7400000
fraction by wt: 30-40%
other rec limits: none specified
osha pel: 10 mg/m3 (fe)
acgih tlv: 5 mg/m3 (fe)
Ld50 lc50 mixture: none specified by manufacturer.
routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: no known health hazard when used as
intended. Inhalation of dust may cause gasping and coughing. No
known hazards from contact or ingestion.
explanation of carcinogenicity: no ingredient of a concentration of 0.1%
or greater is listed as a carcinogen or suspected carcinogen.
effects of overexposure: inhaled-coughing, gasping.
medical cond aggravated by exposure: none specified by manufacturer.
First aid: none specified by manufacturer. Dla-hmis: skin-wash with soap
& water. Inhalation-remove to fresh air. Eyes-flush with water for
15 minutes. Ingested-get medical attention if symptoms develop.
Hcc: n1
melt/freeze pt: m.P/f.P text: >212f,>100c
vapor density: negligible
spec gravity: 1.25-1.65
evaporation rate & reference: negligible
solubility in water: negligible
appearance and odor: fine powder; slight odor.
Stability indicator/materials to avoid: yes
strong oxidizers.
stability condition to avoid: none specified by manufacturer.
hazardous decomposition products: combustion will producce carbon
monoxide and carbon dioxide.
conditions to avoid polymerization: will not occur.
Waste disposal methods: this product may be produced from plastic and/or
metal. Disposal may be subject to local, state and federal
regulations.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: no ingredient for this formulation_ingredient
Ld50 lc50 mixture: ld50 (oral, rat) is not known.
routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: target organs: eyes, respiratory tract.
acute- eyes: no specific hazard known. May cause transient
irritation. Skin: low hazard for industrial handling.
inhale: gasping. Oral: expected to be a low ingestio n hazard.
chronic- unknown.
explanation of carcinogenicity: none
effects of overexposure: transient eye irritation, gasping, coughing
medical cond aggravated by exposure: persons with pre-existing eye
problems or impaired respiratory function may be more susceptible
to the effects of this product.
First aid: get medical help if symptoms persist. Inhaled: move to fresh
air. Eyes: flush with plenty of water, holding eyelids open.
skin: wash with soap & water. Oral: seek medical attention.
Hcc: n1
nrc/state lic num: not relevant
melt/freeze pt: m.P/f.P text: 212-302f
spec gravity: 1.4 - 1.5
viscosity: not relevant
evaporation rate & reference: not relevant
solubility in water: negligible
appearance and odor: black powder - slight plastic odor
Stability indicator/materials to avoid: yes
strong oxidizing agents
stability condition to avoid: dust formation
hazardous decomposition products: carbon monoxide, carbon dioxide,
oxides of iron
Waste disposal methods: discharge, treatment or disposal may be subject
to federal, state or local regulations. Incinerate.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: styrene acrylate copolymer
fraction by wt: 55 - 65%
other rec limits: none recommended
ingred name: iron oxide
cas: 1317-61-9
fraction by wt: 30 - 40%
other rec limits: none recommended
osha pel: 10 mg/m3
acgih tlv: 5 mg/m3
ingred name: salicylic acid chromium (iii) chelate
cas: 72869-85-3
fraction by wt: 1 - 3%
other rec limits: 0.5 mg/m3 as cr(mfr)
ld50 lc50 mixture: none specified by manufacturer.
route of entry inds - inhalation: yes
skin: yes
ingestion: no
carcinogenicity inds - ntp: no
iarc: no
osha: no
effects of exposure: toner low hazard for recommended handling.Toner powder
cant be removed unless cartridge is forces & broken.Inhal: expected to be
low haz for recommended hndlg.Eye: no specific haz known.May cause trans
irrit.Skin: expected to be low haz for recommended hndlg.Ingest: expected to be
low ingest haz.
signs and symptions of overexposure: data frm similar toner matl-human expo to
toner has been shown to cause min resp tract irrit as may occur w/lg atms of
any nontoxic dusts.Resutl of 1animal study where rats inhal toner 10x more
respir able than commercially avai tonser wereobserved to have no lung
changes @low expo(most relevant level to pot human exp)
medical cond aggravated by exposure: none specified by manufacturer.
first aid: inhal: symptomatic move to fresh airs.Get med attn if symptoms
persist.Eye: any matl that contact eye should be washed out imemd w/water.Get
med attn if symptoms occur.Skin: wash w/soap/water.Get med att tn if symptoms
occur.Inest: drink 1-2glasses of water.Seek med attn.
hcc: v1
b.P. Text: na
m.P/f.P text: 212f,100c
vapor pres: na
vapor density: na
spec gravity: 1.5-1.8
ph: na
evaporation rate & reference: na
solubility in water: negligible
appearance and odor: fine powder, black color, typical plastic odor
product id: 1h74a-1 ep-p tnr cartridge black for lbp-430,hp lj iip,iiip
cage: 0yk32
company name: finetone inc
street: 38-38 43rd street
city: long island city ny
zipcode: 11101
health emergency phone: 800-458-6637
label required ind: y
date of label review: 09/02/1998
status code: c
label date: 09/02/1998
year procured: 1998
origination code: f
eye protection ind: yes
skin protection ind: yes
signal word: caution
health hazard: slight
contact hazard: slight
fire hazard: slight
=======================================================
responsible party cage: 0yk32
trans id no: 128998
product id: 1h74a-1 ep-p tnr cartridge black for lbp-430,hp lj iip,iiip
msds prepared date: 01/01/1996
review date: 09/02/1998
mfn: 1
net unit weight: 4l
multiple kit number: 0
review ind: y
unit of issue: ea
container qty: 1
type of container: unknown
additional data: per msds: transp info dot-magnetized material, class 9, un
2807.
Hazard and precautions: toner low haz for recommended hndlg.Toner powder cant
be removed unless cartridge is forced & broken.Inhal: expected to be low
haz for recommended hndlg.Eye: no specific haz known.May cause transt irrit
.Skin: expected to be low haz for recommended hndlg.Ingest: expected to be low
ingest haz.Target organs: eye.1staid: inhal: symptomatic move to fresh airs.Get
med attn if symptoms persist.Eye: any matl that contact eye should be washed
out imemd w/water.Get med attn if symptoms occur.Skin: wash w/soap/water.Get
med atttn if symptoms occur.Inest: drink 1-2glasses of water.Seek med attn.
spill release procedures: no toner spillage occurs in normal operation/hndlg.If
it should occur avoid dust inhal.Sweep matl onto paper,dispo collected toner
as plastic waste.Matl hasnt been tested for enviro effects.Spill situ tation
matl visually unpleasant.Not expected(neut)
neutralizing agent: spill: to cause any adverse enviro effects.
waste disposal methods: incinerate or landfill can be incinerated when in
compliance with local regulations.Discharge/treatment/dispo may be subj to
nat/state/loc laws.
handling and storage precautions: keep from cotnact w/oxidi matls.Min dust
generation/accumulation.Refer: pamphlet#654: preve of fire/dust explo in
chem/dye/pharm/plast industries.
other precautions: use adequate ventilation.Store in cool place.
descrip: assembly for laser beam printer,composed of photosenstive drum,toner
powder,devlpr unit,charger unit,cleaner blades.Toner powder cant be removed u
nless cartridge is forced & broken.
Ld50 lc50 mixture: >5000 mg/kg
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: ingestion: ingestion is not applicable
route of entry for intended use. Inhalation: minimal respiratory
tract irritation may occur with exposure to large amount of toner
dust. Eye: may cause irritatio n. Skin: none currently known.
explanation of carcinogenicity: not a known or suspected carcinogen
according to any arc monograph, ntp, osha regulations (usa), eu
directive, or proposition 65(california).
effects of overexposure: ngestion: ingestion is not applicable route of
entry for intended use. Inhalation: minimal respiratory tract
irritation may occur with exposure to large amount of toner dust.
eye: may cause irritation . Skin: none currently known.
First aid: ingestion: rinse mouth with water, drink one to two glasses
of water. If symptoms occur, consult a physician. Inhalation: move
person to fresh air immediately. If symptoms occur, consult a
physician. Eyes: immediately flush with large amounts of clean,
lukewarm water (low pressure) for at least 15 minutes. If symptoms
occur, consult a physician. Skin: wash affected areas thoroughly
with soap and w ater. If symptoms occur, consult a physician.
Hcc: n1
melt/freeze pt: m.P/f.P text: 100-150c(softening pt)
spec gravity: 1.5-1.8
evaporation rate & reference: n/a(buac=1)
solubility in water: negligible
appearance and odor: fine black powder, slight plastic odor.
Stability indicator/materials to avoid: yes
strong oxidizers
hazardous decomposition products: combustion will produce carbon dioxide
and, possibly toxic chemicals such as carbon monoxide.
Waste disposal methods: recommendation: consultation with the disposal
agency and the relevant authorities; cleansing agent is water.
Ingred name: styrene acrylate copolymer
minumum % wt: 45.
maxumum % wt: 55.
ingred name: iron oxide
cas: 1317-61-9
minumum % wt: 45.
maxumum % wt: 55.