Cross Reference These part numbers have the same form, fit, and function of 2606d97g25

Item Number Cage
23737 20874
MCP13300RS 89946
2606D97G25 89946
MCP13300R 89946
4994D97G25 89946

Characteristic Codes 2606D97G25 spec. code meanings

Code Translation
CPRW Denotes the action imparted by actuator operation.
CPRX An indication of the designated position of the actuator.
CPSF The minimum and maximum values of current to which an adjustable trip setting device may be set per pole, expressed in amperes.
ADAU A measurement from the bottom to the top of the body, in distinction from depth.
ADAQ A measurement of the longest dimension of the body, in distinction from width.
AAQL The style designation indicating the configuration that most nearly corresponds to the appearance of the body.
ADAT A measurement taken at right angles to the length of the body, in distinction from thickness.
ADTV The element, compound, or mixture of which the case is fabricated, excluding any surface treatment.
AEBP The center to center distance between terminals parallel to the length of the item.
AEBQ The center to center distance between terminals parallel to the width of the item.
CPRH Indicates the type of electrical condition that will cause the device to trip.
AEHA The distance between centerlines of mounting facilities parallel to the width of the item.
AEBY The distance between centerlines of mounting facilities parallel to the length of the item.
CBBL Those features, not otherwise specified, which may be required for proper functioning of the item.
FREQ The cycles per second /hertz/ of the alternating current.
CPLM The maximum current load that each pole is rated to carry continuously.
CPRG Indicates the type and value of the maximum short circuit current that the item will successfully interrupt, per pole, at the specified rated voltage, expressed in amperes.
AXHR Indicates the type and number of facilities by which the item is mounted.
CPRF Indicates the type and value of operating voltage for which each pole is designed to operate, expressed in volts.
CQXF Indicates the type of protection for which the inclosure is designed.
CPRR Indicates the type of mechanism provided for tripping main contacts.
CPRT Indicates the type and number of actuators provided for manual control.
CPRQ The means provided to reposition the mechanism so that the device is ready to function.
AKPX The number of poles included in the item.
BBRG Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.
TTQY Indicates the type and number of terminals for providing electrical connection.
CRCF The temperature of the medium surrounding the trip release at which it can be operated continuously.
CPRL Denotes the type of trip release action.
CPRJ The means by which the trip mechanism is released.
CPRN The continuous current rating per pole at which the device must trip in a specified time, expressed in percent.
AEBV The length of a straight line which passes through the center of an unthreaded mounting hole, and terminates at the circumference.

2606D97G25 Circuit Breaker

Mfr. Cage 89946

Specification

CPRW Actuator Function
Trip-reset
CPRX Actuator Position Designation
At pole one
CPSF Adjustable Trip Setting Current Range Per Pole In Amps
+700.0 to 1300.0 ac all locations
ADAU Body Height
3.375 inches
ADAQ Body Length
6.000 inches
AAQL Body Style
Multipole-single actuator type
ADAT Body Width
4.125 inches
AJEC Boss Height
0.125 inches
ADTV Case Material
Plastic
AEBP Center To Center Distance Between Terminals Parallel To Length
5.062 inches
AEBQ Center To Center Distance Between Terminals Parallel To Width
1.375 inches
CPRH Circuit Protection Type
Overcurrent all locations
AEHA Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches
AEBY Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.500 inches
CBBL Features Provided
Adjustable trip release
FREQ Frequency In Hertz
60.0 all locations
CPLM Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations
CPRG Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
14000.0 ac all locations
AXHR Mounting Facility Type And Quantity
4 unthreaded hole
CPRF Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
CQXF Inclosure Protection Type For Which Designed
Dustproof
CPRR Main Contact Tripping Mechanism Type
Trip free
CPRT Manual Actuator Type And Quantity
1 rotary
CPRQ Reset Method
Manual
AKPX Pole Quantity
3
BBRG Storage Type
General purpose warehouse
TTQY Terminal Type And Quantity
6 screw
CRCF Trip Release Ambient Temp Rating
40.0 deg celsius all locations
CPRL Trip Release Characteristic
Instantaneous all locations
CPRJ Trip Release Method
Thermal-magnetic all locations
CPRN Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
AEBV Unthreaded Mounting Hole Diameter
0.187 inches

Technical Definition

Circuit Breaker, also referenced with federal logistics item name code 00136 - A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
National Stock Number (NSN) 5925-00-006-1300

Solicitations

Solicitation Description Qty UOM Close Date
SPE7M517TT405 Circuit Breaker 2 EA 08/28/2017

Last Modified: 08/17/2017