Request Pricing & Availability

NSN: 5925-00-001-5914
Part Number(s):
Quantity:
Company:
Name & Email:
Phone:
Order Terms | Privacy Policy    

Cross Reference These part numbers have the same form, fit, and function of 402023-1

Item Number Cage
3363-20-208VAC60HZCURVE2 08125
402023-1 96214
11900289 82796
3363-20AMP 74193
3363-20-250-60-2 74193

Characteristic Codes 402023-1 spec. code meanings

Code Translation
CPRW Denotes the action imparted by actuator operation.
CPRX An indication of the designated position of the actuator.
ADAU A measurement from the bottom to the top of the body, in distinction from depth.
ADAQ A measurement of the longest dimension of the body, in distinction from width.
AAQL The style designation indicating the configuration that most nearly corresponds to the appearance of the body.
ADAT A measurement taken at right angles to the length of the body, in distinction from thickness.
ADTV The element, compound, or mixture of which the case is fabricated, excluding any surface treatment.
AEBP The center to center distance between terminals parallel to the length of the item.
AEBQ The center to center distance between terminals parallel to the width of the item.
CPRH Indicates the type of electrical condition that will cause the device to trip.
AEHA The distance between centerlines of mounting facilities parallel to the width of the item.
AEBY The distance between centerlines of mounting facilities parallel to the length of the item.
FREQ The cycles per second /hertz/ of the alternating current.
APNQ The means of quenching an arc.
AGAV The national stock number or the identification information of the end equipment for which the item is a part.
CPLM The maximum current load that each pole is rated to carry continuously.
CPRG Indicates the type and value of the maximum short circuit current that the item will successfully interrupt, per pole, at the specified rated voltage, expressed in amperes.
AXHR Indicates the type and number of facilities by which the item is mounted.
CPRF Indicates the type and value of operating voltage for which each pole is designed to operate, expressed in volts.
BBRG Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.
PKWT The measured weight of an item unencumbered by packaging or packing material.
CQXF Indicates the type of protection for which the inclosure is designed.
CPSM The basic internal electrical configuration of the trip mechanism.
CPRR Indicates the type of mechanism provided for tripping main contacts.
CPRT Indicates the type and number of actuators provided for manual control.
CPRQ The means provided to reposition the mechanism so that the device is ready to function.
AKPX The number of poles included in the item.
TTQY Indicates the type and number of terminals for providing electrical connection.
CQWN The length of time, expressed in seconds, that an overload may exist before the device will trip at a specified continuous current.
CPRL Denotes the type of trip release action.
CPRJ The means by which the trip mechanism is released.
CPRN The continuous current rating per pole at which the device must trip in a specified time, expressed in percent.
AEBV The length of a straight line which passes through the center of an unthreaded mounting hole, and terminates at the circumference.

402023-1 Circuit Breaker

Mfr. Cage 74193

Specification

CPRW Actuator Function
Trip-reset
CPRX Actuator Position Designation
At pole two
ADAU Body Height
2.687 inches
ADAQ Body Length
5.250 inches
AAQL Body Style
Multipole-single actuator type
ADAT Body Width
3.000 inches
AJEC Boss Height
0.219 inches
ADTV Case Material
Plastic
AEBP Center To Center Distance Between Terminals Parallel To Length
4.359 inches
AEBQ Center To Center Distance Between Terminals Parallel To Width
1.000 inches
CPRH Circuit Protection Type
Overcurrent all locations
AEHA Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.000 inches
AEBY Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.359 inches
FREQ Frequency In Hertz
60.0 all locations
APNQ Arc Quenching Method
Magnetic blowout
AGAV For Use With/on
Asr7
CPLM Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations
CPRG Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
AXHR Mounting Facility Type And Quantity
4 unthreaded hole
CPRF Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
BBRG Storage Type
General purpose warehouse
PKWT Unpackaged Unit Weight
1.875 pounds
CQXF Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant
CPSM Internal Trip Release Configuration
Series trip all locations
CPRR Main Contact Tripping Mechanism Type
Trip free
CPRT Manual Actuator Type And Quantity
1 toggle
CPRQ Reset Method
Manual
AKPX Pole Quantity
3
TTQY Terminal Type And Quantity
6 compression
CQWN Trip Delay Time In Seconds Per Rated Continuous Current
13.000 minimum at 150 pct all locations and 45.000 maximum at 150 pct all locations and 5.500 minimum at 200 pct all locations and 19.000 maximum at 200 pct all locations
CPRL Trip Release Characteristic
Time delay all locations
CPRJ Trip Release Method
Magnetic-hydraulic all locations
CPRN Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
AEBV Unthreaded Mounting Hole Diameter
0.190 inches

Technical Definition

Circuit Breaker, also referenced with federal logistics item name code 00136 - A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
National Stock Number (NSN) 5925-00-001-5914

Last Modified: 02/08/2017