Part Numbers

Item Number Item Description
6601C86G12 Circuit Breaker
6630C86G21 Circuit Breaker
MCP431550 Circuit Breaker
MCP431550R Circuit Breaker
23740 Circuit Breaker
2606D97G28 Circuit Breaker
4994D97G28 Circuit Breaker

Master Requirement Codes

Code Translation
CPRW Denotes the action imparted by actuator operation.
CPRX An indication of the designated position of the actuator.
CPSF The minimum and maximum values of current to which an adjustable trip setting device may be set per pole, expressed in amperes.
ADAU A measurement from the bottom to the top of the body, in distinction from depth.
ADAQ A measurement of the longest dimension of the body, in distinction from width.
AAQL The style designation indicating the configuration that most nearly corresponds to the appearance of the body.
ADAT A measurement taken at right angles to the length of the body, in distinction from thickness.
ADTV The element, compound, or mixture of which the case is fabricated, excluding any surface treatment.
AEBP The center to center distance between terminals parallel to the length of the item.
AEBQ The center to center distance between terminals parallel to the width of the item.
CPRH Indicates the type of electrical condition that will cause the device to trip.
AEHA The distance between centerlines of mounting facilities parallel to the width of the item.
AEBY The distance between centerlines of mounting facilities parallel to the length of the item.
CBBL Those features, not otherwise specified, which may be required for proper functioning of the item.
FREQ The cycles per second /hertz/ of the alternating current.
CPLM The maximum current load that each pole is rated to carry continuously.
CPRG Indicates the type and value of the maximum short circuit current that the item will successfully interrupt, per pole, at the specified rated voltage, expressed in amperes.
AXHR Indicates the type and number of facilities by which the item is mounted.
CPRF Indicates the type and value of operating voltage for which each pole is designed to operate, expressed in volts.
CQXF Indicates the type of protection for which the inclosure is designed.
CPSM The basic internal electrical configuration of the trip mechanism.
CPRR Indicates the type of mechanism provided for tripping main contacts.
CPRT Indicates the type and number of actuators provided for manual control.
CPRQ The means provided to reposition the mechanism so that the device is ready to function.
AKPX The number of poles included in the item.
BBRG Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.
TTQY Indicates the type and number of terminals for providing electrical connection.
CQWN The length of time, expressed in seconds, that an overload may exist before the device will trip at a specified continuous current.
CPRL Denotes the type of trip release action.
CPRJ The means by which the trip mechanism is released.
CPRN The continuous current rating per pole at which the device must trip in a specified time, expressed in percent.
AEBV The length of a straight line which passes through the center of an unthreaded mounting hole, and terminates at the circumference.

4994D97G28 Circuit Breaker

Cage 89946

Technical Definition

Circuit Breaker, also referenced with federal logistics item name code 00136 - A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.

Technical Characteristics

Actuator Function (CPRW):
Trip-reset
Actuator Position Designation (CPRX):
At pole two
Adjustable Trip Setting Current Range Per Pole In Amps (CPSF):
+450.0 to 825.0 ac all locations
Body Height (ADAU):
3.375 inches nominal
Body Length (ADAQ):
6.000 inches nominal
Body Style (AAQL):
Multipole-single actuator type
Body Width (ADAT):
4.125 inches nominal
Boss Height (AJEC):
0.125 inches nominal
Case Material (ADTV):
Plastic
Center To Center Distance Between Terminals Parallel To Length (AEBP):
5.062 inches nominal
Center To Center Distance Between Terminals Parallel To Width (AEBQ):
1.375 inches nominal
Circuit Protection Type (CPRH):
Overcurrent all locations
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width (AEHA):
1.375 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length (AEBY):
4.500 inches nominal
Features Provided (CBBL):
Adjustable trip release
Frequency In Hertz (FREQ):
60.0 all locations
Maximum Continuous Load Current Rating Per Pole (CPLM):
150.0 amperes ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps (CPRG):
10000.0 ac all locations
Mounting Facility Type And Quantity (AXHR):
4 unthreaded hole
Operating Voltage Type And Rating Per Pole In Volts (CPRF):
600.0 ac all locations
Inclosure Protection Type For Which Designed (CQXF):
Fungus resistant and moisture resistant
Internal Trip Release Configuration (CPSM):
Series trip all locations
Main Contact Tripping Mechanism Type (CPRR):
Trip free
Manual Actuator Type And Quantity (CPRT):
1 toggle
Reset Method (CPRQ):
Manual
Pole Quantity (AKPX):
3
Storage Type (BBRG):
General purpose warehouse
Terminal Type And Quantity (TTQY):
6 compression
Trip Delay Time In Seconds Per Rated Continuous Current (CQWN):
200.000 maximum at 200 pct all locations
Trip Release Characteristic (CPRL):
Instantaneous all locations
Trip Release Method (CPRJ):
Magnetic all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent (CPRN):
115.0 all locations
Unthreaded Mounting Hole Diameter (AEBV):
0.187 inches nominal

National Stock Number (NSN)