Home » FSC Catalog » Circuit Breakers » 6752-304-10

Price and Stock Check

We will send you instructions on purchasing this NSN*
NSN: 5925-00-001-5942
Part Number(s):
Quantity:
Company:
Name & Email:
Phone:
Order Terms | Privacy Policy    

Cross Reference

These part numbers have the same form, fit, and function of 6752-304-10
Item Number Cage
BACC182L10A 81205
6752-304-10 82647
D6760-17-10 82647

Characteristic Codes

6752-304-10 spec. code meanings
Code Translation
AAQL The style designation indicating the configuration that most nearly corresponds to the appearance of the body.
ABXD A measurement of the longest dimension of a bushing, in distinction from width.
ADAQ A measurement of the longest dimension of the body, in distinction from width.
ADAT A measurement taken at right angles to the length of the body, in distinction from thickness.
ADAU A measurement from the bottom to the top of the body, in distinction from depth.
ADTV The element, compound, or mixture of which the case is fabricated, excluding any surface treatment.
AEBP The center to center distance between terminals parallel to the length of the item.
AEBQ The center to center distance between terminals parallel to the width of the item.
AEBY The distance between centerlines of mounting facilities parallel to the length of the item.
AEHA The distance between centerlines of mounting facilities parallel to the width of the item.
AFJN The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.
AKPX The number of poles included in the item.
AXHR Indicates the type and number of facilities by which the item is mounted.
BBRG Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.
CMLP The number of threads on the item per linear inch measured on a line parallel to the thread axis.
CPLM The maximum current load that each pole is rated to carry continuously.
CPRF Indicates the type and value of operating voltage for which each pole is designed to operate, expressed in volts.
CPRG Indicates the type and value of the maximum short circuit current that the item will successfully interrupt, per pole, at the specified rated voltage, expressed in amperes.
CPRH Indicates the type of electrical condition that will cause the device to trip.
CPRJ The means by which the trip mechanism is released.
CPRL Denotes the type of trip release action.
CPRN The continuous current rating per pole at which the device must trip in a specified time, expressed in percent.
CPRQ The means provided to reposition the mechanism so that the device is ready to function.
CPRR Indicates the type of mechanism provided for tripping main contacts.
CPRT Indicates the type and number of actuators provided for manual control.
CPRW Denotes the action imparted by actuator operation.
CPRX An indication of the designated position of the actuator.
CPSM The basic internal electrical configuration of the trip mechanism.
CQJX A designation that is used for the purpose of general identification of the thread.
CQWN The length of time, expressed in seconds, that an overload may exist before the device will trip at a specified continuous current.
CQXF Indicates the type of protection for which the inclosure is designed.
CRCF The temperature of the medium surrounding the trip release at which it can be operated continuously.
FREQ The cycles per second /hertz/ of the alternating current.
PKWT The measured weight of an item unencumbered by packaging or packing material.
PMLC An indication of the precious material and its location in the item.
PRMT Identification of the precious material contained in the item.
TEST The specification, standard, drawing, or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.
THSD A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
TTQY Indicates the type and number of terminals for providing electrical connection.

6752-304-10

Description: Circuit Breaker
Mfr. Cage 82647

Specification

Thread Size: 9/64"

AAQL Body Style
Multipole-single actuator type
ABXD Bushing Length
From 0.220" and 0.280"
ADAQ Body Length
2.200 inches maximum
ADAT Body Width
2.250 inches maximum
ADAU Body Height
2.125 inches maximum
ADTV Case Material
Plastic
AEBP Center To Center Distance Between Terminals Parallel To Length
From 1.471" and 1.501"
AEBQ Center To Center Distance Between Terminals Parallel To Width
From 0.735" and 0.751"
AEBY Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
From 1.780" and 1.840"
AEHA Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
From 0.735" and 0.751"
AFJN Fragility Factor
Moderately rugged
AKPX Pole Quantity
3
AXHR Mounting Facility Type And Quantity
6 threaded hole
BBRG Storage Type
General purpose warehouse
CMLP Thready Qty Per Inch (tpi)
32
CPLM Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations
CPRF Operating Voltage Type And Rating Per Pole In Volts
200.0 ac all locations
CPRG Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations
CPRH Circuit Protection Type
Overcurrent all locations
CPRJ Trip Release Method
Thermal all locations
CPRL Trip Release Characteristic
Time delay all locations
CPRN Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
CPRQ Reset Method
Manual
CPRR Main Contact Tripping Mechanism Type
Trip free
CPRT Manual Actuator Type And Quantity
1 push-pull
CPRW Actuator Function
Trip-reset
CPRX Actuator Position Designation
At pole two
CPSM Internal Trip Release Configuration
Series trip all locations
CQJX Nominal Thread Size
0.138 inches
CQWN Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct all locations and 65.000 maximum at 200 pct all locations
CQXF Inclosure Protection Type For Which Designed
General purpose
CRCF Trip Release Ambient Temp Rating
25.0 deg celsius all locations
FREQ Frequency In Hertz
400.0 all locations
PKWT Unpackaged Unit Weight
0.500 pounds
PMLC Precious Material And Location
Terminal surfaces silver
PRMT Precious Material
Silver
TEST Test Data Document
81205-bacc182l10a drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
THSD Thread Series Designator
Unc
TTQY Terminal Type And Quantity
6 screw

Technical Definition

Circuit Breaker, also referenced with federal logistics item name code 00136 - A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
National Stock Number (NSN) 5925-00-001-5942

Last Modified: 02/14/2017