Circuit Breaker

Model / MPN: 841425-1 | NSN: 5925-01-330-8678
ITAR Registered seal

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating elemen (s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified) ; and controller.

Product Details
NATO Stock Number
5925-01-330-8678
Sold in multiples of
1 EA
DEMIL
NO
Body Style
Multipole-multiple actuator type
Mounting Slot Width
0.164 inches
Body Length
Between 4.740 inches and 4.760 inches
Body Width
5.180 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
Between 3.537 inches and 3.557 inches
Center To Center Distance Between Terminals Parallel To Width
Between 1.016 inches and 1.036 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.740 inches and 2.760 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 1.016 inches and 1.036 inches
Fragility Factor
Moderately rugged
Boss Height
Between 0.209 inches and 0.229 inches
Mounting Surface To Terminal End Distance
Between 3.475 inches and 3.495 inches
Pole Quantity
5
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
10 threaded hole and 5 slot
Storage Type
General purpose warehouse
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc fifth location
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc fourth location
Operating Voltage Type And Rating Per Pole In Volts
140.0 dc fifth location
Operating Voltage Type And Rating Per Pole In Volts
140.0 dc fourth location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc fifth location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc fourth location
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic-hydraulic all locations
Auxiliary Trip Coil Voltage Type And Rating In Volts
25.0 dc first location
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
5 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At each pole
External Actuator Linkage Arrangement
One, two, three, four, and five linked
Internal Trip Release Configuration
Series trip fifth location
Internal Trip Release Configuration
Series trip fourth location
Internal Trip Release Configuration
Series trip second location
Internal Trip Release Configuration
Series trip third location
Internal Trip Release Configuration
Series/relay trip first location
Thread Size
0.138 inches
Trip Release Duty Cycle
Continuous first location
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 at 200 pct second location and 100.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 at 200 pct first location and 100.000 at 200 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 at 200 pct third location and 100.000 at 200 pct third location
Trip Delay Time In Seconds Per Rated Continuous Current
25.000 at 200 pct fifth location and 95.000 at 200 pct fifth location
Trip Delay Time In Seconds Per Rated Continuous Current
25.000 at 200 pct fourth location and 95.000 at 200 pct fourth location
Inclosure Protection Type For Which Designed
Vibration resistant and shock resistant and moisture resistant and salt spray proof
Frequency In Hertz
60.0 first location
Frequency In Hertz
60.0 second location
Frequency In Hertz
60.0 third location
Thread Series Designator
Unc
Terminal Type And Quantity
12 threaded stud
841425 Series Parts
Solicitations
Solicitation Description Qty UOM Close Date
SPE7M516TH703 Circuit Breaker 14 EA 08/29/2016

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping
841425-1 Cross Reference
  • 841425-1
  • CD5-Z30-1
  • CD5-Z14-1
  • CD5-Z14-1