Circuit Breaker

Model / MPN: APGH9666-1REC4-21863-1 | NSN: 5925-01-262-6150
ITAR Registered seal

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating elemen (s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified) ; and controller.

Product Details
NATO Stock Number
5925-01-262-6150
Sold in multiples of
1 EA
DEMIL
NO
Body Style
Multipole-multiple actuator type
Body Length
2.000 inches
Body Width
3.015 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.560 inches
Center To Center Distance Between Terminals Parallel To Width
0.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches
Switch Contact Arrangement
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches
Boss Height
0.130 inches
Mounting Surface To Terminal End Distance
2.032 inches
Pole Quantity
4
Mounting Facility Type And Quantity
8 threaded hole
Storage Type
General purpose warehouse
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac fourth location and 15.0 amperes dc fourth location
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac third location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac fourth location and 65.0 dc fourth location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac fourth location and 1000.0 dc fourth location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac third location
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
4 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At each pole
External Actuator Linkage Arrangement
One, two, three, and four linked
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
Series trip first location
Internal Trip Release Configuration
Relay trip fourth location
Internal Trip Release Configuration
Series trip second location
Internal Trip Release Configuration
Series trip third location
Thread Size
0.138 inches
Switch Location And Position Designation
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct all locations and 1.900 at 200 pct all locations
Inclosure Protection Type For Which Designed
Moisture resistant and shock resistant and vibration resistant
Switch Terminal Type
Tab, solder lug
Switch Current Rating And Type In Amps
5.0 ac and 5.0 dc
Switch Voltage Rating And Type In Volts
240.0 ac and 50.0 dc
Frequency In Hertz
400.0 all locations
Test Data Document
18323-7489a63 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator
Unc
Terminal Type And Quantity
10 tab w/screw

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping
APGH9666-1REC4-21863-1 Cross Reference
  • 7489A63H01