NATO Stock Number
5925-01-130-1797
Sold in multiples of
1 EA
DEMIL
NO
Thread Pitch Diameters
+0.1177/+0.1214 inches
Body Style
Multipole-multiple actuator type
Body Length
Between 2.480 inches and 2.500 inches
Body Width
2.250 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.940 inches
Center To Center Distance Between Terminals Parallel To Width
0.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.050 inches and 2.070 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches
Fragility Factor
Moderately rugged
Boss Height
0.150 inches
Mounting Surface To Terminal End Distance
2.475 inches
Pole Quantity
4
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
8 threaded hole
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole
6.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole
6.0 amperes ac second location
Operating Voltage Type And Rating Per Pole In Volts
115.0 dc fourth location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac second location
Circuit Protection Type
Overcurrent first location
Circuit Protection Type
Overcurrent second location
Circuit Protection Type
Overcurrent third location
Circuit Protection Type
Undervoltage fourth location
Trip Release Method
Magnetic-hydraulic all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
4 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At each pole
External Actuator Linkage Arrangement
One, two, three, and four linked
Internal Trip Release Configuration
Series trip first location
Internal Trip Release Configuration
Relay trip fourth location
Internal Trip Release Configuration
Series trip second location
Internal Trip Release Configuration
Series trip third location
Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.024 at 200 pct fourth location
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct first location and 1.500 at 200 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct second location and 1.500 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct third location and 1.500 at 200 pct third location
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant
Frequency In Hertz
60.0 first location
Frequency In Hertz
60.0 second location
Frequency In Hertz
60.0 third location
Thread Series Designator
Unc
Terminal Type And Quantity
10 threaded stud