NATO Stock Number
5925-01-074-3043
Sold in multiples of
1 EA
DEMIL
NO
Thread Pitch Diameters
+0.1177/+0.1214 inches
Body Style
Multipole-multiple actuator type
Body Length
2.490 inches
Body Width
3.015 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.940 inches
Center To Center Distance Between Terminals Parallel To Width
0.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches
Boss Height
0.150 inches
Mounting Surface To Terminal End Distance
2.491 inches
Pole Quantity
4
Mounting Facility Type And Quantity
8 threaded hole
Storage Type
General purpose warehouse
Special Handling Feature
Magnetic
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac third location
Operating Voltage Type And Rating Per Pole In Volts
24.0 dc fourth location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac second location
Circuit Protection Type
Overcurrent first location
Circuit Protection Type
Overvoltage fourth location
Circuit Protection Type
Overcurrent second location
Circuit Protection Type
Overcurrent third location
Trip Release Method
Magnetic all locations
Trip Release Characteristic
Instantaneous fourth location
Trip Release Characteristic
Time delay second location
Trip Release Characteristic
Time delay third location
Trip Release Characteristic
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 second location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 third location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 fourth location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
4 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At each pole
External Actuator Linkage Arrangement
One, two, three, and four linked
Internal Trip Release Configuration
Series trip fourth location
Internal Trip Release Configuration
Shunt trip second location
Internal Trip Release Configuration
Shunt trip third location
Internal Trip Release Configuration
Shunt trip first location
Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
Any acceptable first location
Trip Delay Time In Seconds Per Rated Continuous Current
Any acceptable second location
Trip Delay Time In Seconds Per Rated Continuous Current
Any acceptable third location
Inclosure Protection Type For Which Designed
Corrosion resistant and moisture resistant
Frequency In Hertz
60.0 first location
Frequency In Hertz
60.0 second location
Frequency In Hertz
60.0 third location
Thread Series Designator
Unc
Terminal Type And Quantity
11 threaded stud