Item Number Item Description
BACC182L10A Circuit Breaker
6752-304-10 Circuit Breaker
D6760-17-10 Circuit Breaker

Master Requirement Codes

Code Translation
CPRW Denotes the action imparted by actuator operation.
CPRX An indication of the designated position of the actuator.
ADAU A measurement from the bottom to the top of the body, in distinction from depth.
ADAQ A measurement of the longest dimension of the body, in distinction from width.
AAQL The style designation indicating the configuration that most nearly corresponds to the appearance of the body.
ADAT A measurement taken at right angles to the length of the body, in distinction from thickness.
ABXD A measurement of the longest dimension of a bushing, in distinction from width.
ADTV The element, compound, or mixture of which the case is fabricated, excluding any surface treatment.
AEBP The center to center distance between terminals parallel to the length of the item.
AEBQ The center to center distance between terminals parallel to the width of the item.
CPRH Indicates the type of electrical condition that will cause the device to trip.
AEBY The distance between centerlines of mounting facilities parallel to the length of the item.
AEHA The distance between centerlines of mounting facilities parallel to the width of the item.
FREQ The cycles per second /hertz/ of the alternating current.
CPLM The maximum current load that each pole is rated to carry continuously.
CPRG Indicates the type and value of the maximum short circuit current that the item will successfully interrupt, per pole, at the specified rated voltage, expressed in amperes.
AXHR Indicates the type and number of facilities by which the item is mounted.
CQJX A designation that is used for the purpose of general identification of the thread.
CPRF Indicates the type and value of operating voltage for which each pole is designed to operate, expressed in volts.
AFJN The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.
PRMT Identification of the precious material contained in the item.
BBRG Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.
PKWT The measured weight of an item unencumbered by packaging or packing material.
CQXF Indicates the type of protection for which the inclosure is designed.
CPSM The basic internal electrical configuration of the trip mechanism.
CPRR Indicates the type of mechanism provided for tripping main contacts.
CPRT Indicates the type and number of actuators provided for manual control.
CPRQ The means provided to reposition the mechanism so that the device is ready to function.
AKPX The number of poles included in the item.
PMLC An indication of the precious material and its location in the item.
TTQY Indicates the type and number of terminals for providing electrical connection.
TEST The specification, standard, drawing, or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.
CMLP The number of threads on the item per linear inch measured on a line parallel to the thread axis.
THSD A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
CQWN The length of time, expressed in seconds, that an overload may exist before the device will trip at a specified continuous current.
CRCF The temperature of the medium surrounding the trip release at which it can be operated continuously.
CPRL Denotes the type of trip release action.
CPRJ The means by which the trip mechanism is released.
CPRN The continuous current rating per pole at which the device must trip in a specified time, expressed in percent.

D6760-17-10 Circuit Breaker

Cage 82647

Technical Definition

Circuit Breaker, also referenced with federal logistics item name code 00136 - A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.

Technical Characteristics

Actuator Function (CPRW):
Trip-reset
Actuator Position Designation (CPRX):
At pole two
Body Height (ADAU):
2.125 inches maximum
Body Length (ADAQ):
2.200 inches maximum
Body Style (AAQL):
Multipole-single actuator type
Body Width (ADAT):
2.250 inches maximum
Bushing Length (ABXD):
0.220 inches minimum and 0.280 inches maximum
Case Material (ADTV):
Plastic
Center To Center Distance Between Terminals Parallel To Length (AEBP):
1.471 inches minimum and 1.501 inches maximum
Center To Center Distance Between Terminals Parallel To Width (AEBQ):
0.735 inches minimum and 0.751 inches maximum
Circuit Protection Type (CPRH):
Overcurrent all locations
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length (AEBY):
1.780 inches minimum and 1.840 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width (AEHA):
0.735 inches minimum and 0.751 inches maximum
Frequency In Hertz (FREQ):
400.0 all locations
Maximum Continuous Load Current Rating Per Pole (CPLM):
10.0 amperes ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps (CPRG):
1500.0 ac all locations
Mounting Facility Type And Quantity (AXHR):
6 threaded hole
Nominal Thread Size (CQJX):
0.138 inches
Operating Voltage Type And Rating Per Pole In Volts (CPRF):
200.0 ac all locations
Fragility Factor (AFJN):
Moderately rugged
Precious Material (PRMT):
Silver
Storage Type (BBRG):
General purpose warehouse
Unpackaged Unit Weight (PKWT):
0.500 pounds
Inclosure Protection Type For Which Designed (CQXF):
General purpose
Internal Trip Release Configuration (CPSM):
Series trip all locations
Main Contact Tripping Mechanism Type (CPRR):
Trip free
Manual Actuator Type And Quantity (CPRT):
1 push-pull
Reset Method (CPRQ):
Manual
Pole Quantity (AKPX):
3
Precious Material And Location (PMLC):
Terminal surfaces silver
Terminal Type And Quantity (TTQY):
6 screw
Test Data Document (TEST):
81205-bacc182l10a drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Quantity Per Inch (CMLP):
32
Thread Series Designator (THSD):
Unc
Trip Delay Time In Seconds Per Rated Continuous Current (CQWN):
10.000 minimum at 200 pct all locations and 65.000 maximum at 200 pct all locations
Trip Release Ambient Temp Rating (CRCF):
25.0 deg celsius nominal all locations
Trip Release Characteristic (CPRL):
Time delay all locations
Trip Release Method (CPRJ):
Thermal all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent (CPRN):
150.0 all locations