Request Pricing & Availability

NSN: 5925-00-001-5942
Part Number(s):
Quantity:
Company:
Name & Email:
Phone:
Order Terms | Privacy Policy    

Cross Reference These part numbers have the same form, fit, and function of d6760-17-10

Item Number Cage
BACC182L10A 81205
6752-304-10 82647
D6760-17-10 82647

Characteristic Codes D6760-17-10 spec. code meanings

Code Translation
CPRW Denotes the action imparted by actuator operation.
CPRX An indication of the designated position of the actuator.
ADAU A measurement from the bottom to the top of the body, in distinction from depth.
ADAQ A measurement of the longest dimension of the body, in distinction from width.
AAQL The style designation indicating the configuration that most nearly corresponds to the appearance of the body.
ADAT A measurement taken at right angles to the length of the body, in distinction from thickness.
ABXD A measurement of the longest dimension of a bushing, in distinction from width.
ADTV The element, compound, or mixture of which the case is fabricated, excluding any surface treatment.
AEBP The center to center distance between terminals parallel to the length of the item.
AEBQ The center to center distance between terminals parallel to the width of the item.
CPRH Indicates the type of electrical condition that will cause the device to trip.
AEBY The distance between centerlines of mounting facilities parallel to the length of the item.
AEHA The distance between centerlines of mounting facilities parallel to the width of the item.
FREQ The cycles per second /hertz/ of the alternating current.
CPLM The maximum current load that each pole is rated to carry continuously.
CPRG Indicates the type and value of the maximum short circuit current that the item will successfully interrupt, per pole, at the specified rated voltage, expressed in amperes.
AXHR Indicates the type and number of facilities by which the item is mounted.
CQJX A designation that is used for the purpose of general identification of the thread.
CPRF Indicates the type and value of operating voltage for which each pole is designed to operate, expressed in volts.
AFJN The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.
PRMT Identification of the precious material contained in the item.
BBRG Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.
PKWT The measured weight of an item unencumbered by packaging or packing material.
CQXF Indicates the type of protection for which the inclosure is designed.
CPSM The basic internal electrical configuration of the trip mechanism.
CPRR Indicates the type of mechanism provided for tripping main contacts.
CPRT Indicates the type and number of actuators provided for manual control.
CPRQ The means provided to reposition the mechanism so that the device is ready to function.
AKPX The number of poles included in the item.
PMLC An indication of the precious material and its location in the item.
TTQY Indicates the type and number of terminals for providing electrical connection.
TEST The specification, standard, drawing, or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.
CMLP The number of threads on the item per linear inch measured on a line parallel to the thread axis.
THSD A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
CQWN The length of time, expressed in seconds, that an overload may exist before the device will trip at a specified continuous current.
CRCF The temperature of the medium surrounding the trip release at which it can be operated continuously.
CPRL Denotes the type of trip release action.
CPRJ The means by which the trip mechanism is released.
CPRN The continuous current rating per pole at which the device must trip in a specified time, expressed in percent.

D6760-17-10 Circuit Breaker

Mfr. Cage 82647

Specification

Thread Size: 9/64"

CPRW Actuator Function
Trip-reset
CPRX Actuator Position Designation
At pole two
ADAU Body Height
2.125 inches maximum
ADAQ Body Length
2.200 inches maximum
AAQL Body Style
Multipole-single actuator type
ADAT Body Width
2.250 inches maximum
ABXD Bushing Length
From 0.220" and 0.280"
ADTV Case Material
Plastic
AEBP Center To Center Distance Between Terminals Parallel To Length
From 1.471" and 1.501"
AEBQ Center To Center Distance Between Terminals Parallel To Width
From 0.735" and 0.751"
CPRH Circuit Protection Type
Overcurrent all locations
AEBY Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
From 1.780" and 1.840"
AEHA Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
From 0.735" and 0.751"
FREQ Frequency In Hertz
400.0 all locations
CPLM Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations
CPRG Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations
AXHR Mounting Facility Type And Quantity
6 threaded hole
CQJX Nominal Thread Size
0.138 inches
CPRF Operating Voltage Type And Rating Per Pole In Volts
200.0 ac all locations
AFJN Fragility Factor
Moderately rugged
PRMT Precious Material
Silver
BBRG Storage Type
General purpose warehouse
PKWT Unpackaged Unit Weight
0.500 pounds
CQXF Inclosure Protection Type For Which Designed
General purpose
CPSM Internal Trip Release Configuration
Series trip all locations
CPRR Main Contact Tripping Mechanism Type
Trip free
CPRT Manual Actuator Type And Quantity
1 push-pull
CPRQ Reset Method
Manual
AKPX Pole Quantity
3
PMLC Precious Material And Location
Terminal surfaces silver
TTQY Terminal Type And Quantity
6 screw
TEST Test Data Document
81205-bacc182l10a drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
CMLP Thready Qty Per Inch (tpi)
32
THSD Thread Series Designator
Unc
CQWN Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct all locations and 65.000 maximum at 200 pct all locations
CRCF Trip Release Ambient Temp Rating
25.0 deg celsius all locations
CPRL Trip Release Characteristic
Time delay all locations
CPRJ Trip Release Method
Thermal all locations
CPRN Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations

Technical Definition

Circuit Breaker, also referenced with federal logistics item name code 00136 - A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
National Stock Number (NSN) 5925-00-001-5942

Last Modified: 02/14/2017