Secure Ordering: +1 (757) 528-8028
NationalStockNumber.info
NationalStockNumber.INFO

Worldwide distributor of NSN parts and consumables located in the USA.

Band Pass Filter

Model / MPN: MB-1535 | NSN: 5915-01-150-6414
ITAR Registered seal

An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See coil (as modified); reactor; capacitor (as modified); and resistor (as modified).

Product Details
NATO Stock Number
5915-01-150-6414
Sold in multiples of
1 EA
DEMIL
NO
Overall Height
0.850 inches
Body Length
3.035 inches
Body Width
1.875 inches
Body Height
0.580 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.624 inches
Vibration Resistance Range In Hertz
+10.0/+2000.0
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.500 inches
Operating Tempurature Range
-29.0/+85.0 degrees celsius
Reference Frequency Per Function
15.056 single radio interference pulses per second
Reference Frequency Per Function
21.376 single radio interference two phase to two phase
Reference Frequency Per Function
23.632 single radio interference two phase to three phase
Reference Frequency Per Function
36.0 single radio interference hertz
Reference Frequency Per Function
41.6 single radio interference three phase to two phase
Source Impedance Rating Per Function
1.0 kilohms 3rd band pass
Source Impedance Rating Per Function
1.0 kilohms 4th band pass
Source Impedance Rating Per Function
1.0 kilohms 5th band pass
Source Impedance Rating Per Function
1.0 kilohms 1st band pass
Source Impedance Rating Per Function
1.0 kilohms 2nd band pass
Load Impedance Per Function
100.0 kilohms 1st band pass
Load Impedance Per Function
100.0 kilohms 2nd band pass
Load Impedance Per Function
100.0 kilohms 3rd band pass
Load Impedance Per Function
100.0 kilohms 4th band pass
Load Impedance Per Function
100.0 kilohms 5th band pass
Inclosure Type
Encased
Mounting Facility Type And Quantity
5 plug-in
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 4th band pass
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 5th band pass
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 3rd band pass
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
Functional Terminal Type And Quantity
1 pin ground 3rd function
Functional Terminal Type And Quantity
2 pin input 1st function
Functional Terminal Type And Quantity
5 pin output 2nd function
Specified Frequencies Of Discrimination Per Function
14.608 kilohertz 1st band pass 1st function and 14.752 kilohertz 1st band pass 1st function and 15.344 kilohertz 1st band pass 1st function and 15.52 kilohertz 1st band pass 1st function
Specified Frequencies Of Discrimination Per Function
34.928 kilohertz 4th band pass 4th function and 35.28 kilohertz 4th band pass 4th function and 36.72 kilohertz 4th band pass 4th function and 37.072 kilohertz 4th band pass 4th function
Specified Frequencies Of Discrimination Per Function
40.352 kilohertz 5th band pass 5th function and 40.784 kilohertz 5th band pass 5th function and 42.416 kilohertz 5th band pass 5th function and 42.848 kilohertz 5th band pass 5th function
Specified Frequencies Of Discrimination Per Function
20.736 kilohertz 2nd band pass 2nd function and 20.944 kilohertz 2nd band pass 2nd function and 21.792 kilohertz 2nd band pass 2nd function and 22.032 kilohertz 2nd band pass 2nd function
Specified Frequencies Of Discrimination Per Function
22.928 kilohertz 3rd band pass 3rd function and 23.168 kilohertz 3rd band pass 3rd function and 24.096 kilohertz 3rd band pass 3rd function and 24.352 kilohertz 3rd band pass 3rd function
Frequency Band Width Per Function
14.752 kilohertz 1st band pass and 15.344 kilohertz 1st band pass
Frequency Band Width Per Function
20.944 kilohertz 2nd band pass and 21.792 kilohertz 2nd band pass
Frequency Band Width Per Function
23.168 kilohertz 3rd band pass and 24.096 kilohertz 3rd band pass
Frequency Band Width Per Function
35.28 kilohertz 4th band pass and 36.72 kilohertz 4th band pass
Frequency Band Width Per Function
40.784 kilohertz 5th band pass and 42.416 kilohertz 5th band pass
Discrimination At Specificationified Frequencies Per Function In Decibels
30.0 2nd band pass 2nd function and 3.0 2nd band pass 2nd function and 3.0 2nd band pass 2nd function and 30.0 2nd band pass 2nd function
Discrimination At Specificationified Frequencies Per Function In Decibels
30.0 3rd band pass 3rd function and 3.0 3rd band pass 3rd function and 3.0 3rd band pass 3rd function and 30.0 3rd band pass 3rd function
Discrimination At Specificationified Frequencies Per Function In Decibels
30.0 1st band pass 1st function and 3.0 1st band pass 1st function and 3.0 1st band pass 1st function and 30.0 1st band pass 1st function
Discrimination At Specificationified Frequencies Per Function In Decibels
30.0 4th band pass 4th function and 3.0 4th band pass 4th function and 3.0 4th band pass 4th function and 30.0 4th band pass 4th function
Discrimination At Specificationified Frequencies Per Function In Decibels
30.0 5th band pass 5th function and 3.0 5th band pass 5th function and 3.0 5th band pass 5th function and 30.0 5th band pass 5th function
Body Surface Treatment
Tin
Unpackaged Unit Weight
6.500 ounces
Style Designator
Rectangular terminal/terminals on one surface

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping
MB-1535 Cross Reference
  • 10B66
  • SM-A-838216-6
  • SM-A-838216-6
  • SM-A-838216-6