Home » FSC Catalog » Circuit Breakers » MS39069-1

Price and Stock Check

We will send you instructions on purchasing this NSN*
NSN: 5925-00-004-5817
Part Number(s):
Quantity:
Company:
Name & Email:
Phone:
Order Terms | Privacy Policy    

Cross Reference

These part numbers have the same form, fit, and function of ms39069-1
Item Number Cage
120932 57633
AA55571/08-001 58536
AA55571/8 58536
7855-7-175 82647
M13516/8-6 81349
MS39069-1 96906
MIL-C-13516/8 81349
M13516/8BII-175 81349

Characteristic Codes

MS39069-1 spec. code meanings
Code Translation
AAQL The style designation indicating the configuration that most nearly corresponds to the appearance of the body.
ABHP The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.
ADAT A measurement taken at right angles to the length of the body, in distinction from thickness.
ADTV The element, compound, or mixture of which the case is fabricated, excluding any surface treatment.
AEBP The center to center distance between terminals parallel to the length of the item.
AEBV The length of a straight line which passes through the center of an unthreaded mounting hole, and terminates at the circumference.
AEBY The distance between centerlines of mounting facilities parallel to the length of the item.
AEHA The distance between centerlines of mounting facilities parallel to the width of the item.
AFJN The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.
AKPX The number of poles included in the item.
AXHR Indicates the type and number of facilities by which the item is mounted.
BBRG Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.
CPLM The maximum current load that each pole is rated to carry continuously.
CPRF Indicates the type and value of operating voltage for which each pole is designed to operate, expressed in volts.
CPRG Indicates the type and value of the maximum short circuit current that the item will successfully interrupt, per pole, at the specified rated voltage, expressed in amperes.
CPRH Indicates the type of electrical condition that will cause the device to trip.
CPRJ The means by which the trip mechanism is released.
CPRL Denotes the type of trip release action.
CPRN The continuous current rating per pole at which the device must trip in a specified time, expressed in percent.
CPRQ The means provided to reposition the mechanism so that the device is ready to function.
CPSM The basic internal electrical configuration of the trip mechanism.
CQWN The length of time, expressed in seconds, that an overload may exist before the device will trip at a specified continuous current.
CQXF Indicates the type of protection for which the inclosure is designed.
CRCF The temperature of the medium surrounding the trip release at which it can be operated continuously.
TEST The specification, standard, drawing, or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.
TTQY Indicates the type and number of terminals for providing electrical connection.
ZZZK The document designator of the specification or standard which established the item of supply.

MS39069-1

Description: Circuit Breaker
Mfr. Cage 81349

Specification

Length: 4-1/64"

AAQL Body Style
Single pole type
ABHP Overall Length
4.000 inches
ADAT Body Width
2.120 inches
ADTV Case Material
Plastic
AEBP Center To Center Distance Between Terminals Parallel To Length
From 1.485" and 1.515"
AEBV Unthreaded Mounting Hole Diameter
0.218 inches
AEBY Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.500 inches
AEHA Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.000 inches
AFJN Fragility Factor
Moderately rugged
AJWX Mounting Surface To Terminal End Distance
2.220 inches
AKPX Pole Quantity
1
AXHR Mounting Facility Type And Quantity
4 unthreaded hole
BBRG Storage Type
General purpose warehouse
CPLM Maximum Continuous Load Current Rating Per Pole
175.0 amperes dc single location
CPRF Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location
CPRG Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
575.0 dc single location
CPRH Circuit Protection Type
Overcurrent single location
CPRJ Trip Release Method
Thermal single location
CPRL Trip Release Characteristic
Time delay single location
CPRN Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
CPRQ Reset Method
Automatic
CPSM Internal Trip Release Configuration
Series trip single location
CQWN Trip Delay Time In Seconds Per Rated Continuous Current
8.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location
CQXF Inclosure Protection Type For Which Designed
Vibration resistant and shock resistant and salt spray proof and fungus resistant
CRCF Trip Release Ambient Temp Rating
25.0 deg celsius single location
TEST Test Data Document
81349-mil-c-13516 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
TTQY Terminal Type And Quantity
2 threaded stud
ZZZK Specification
81349--13516/8bii government specification

Technical Definition

Circuit Breaker, also referenced with federal logistics item name code 00136 - A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
National Stock Number (NSN) 5925-00-004-5817

Last Modified: 02/14/2017