NATO Stock Number
5925-01-104-7348
Sold in multiples of
1 EA
DEMIL
NO
Body Style
Multipole-multiple actuator type
Body Length
2.500 inches
Body Width
3.060 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.955 inches
Center To Center Distance Between Terminals Parallel To Width
0.760 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.070 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.760 inches
Boss Height
0.165 inches
Mounting Surface To Terminal End Distance
2.491 inches
Pole Quantity
4
Mounting Facility Type And Quantity
8 threaded hole
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac first location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac third location
Circuit Protection Type
Overcurrent first location
Circuit Protection Type
Overcurrent second location
Circuit Protection Type
Overcurrent third location
Trip Release Method
Magnetic first location
Trip Release Method
Magnetic second location
Trip Release Method
Magnetic third location
Trip Release Characteristic
Time delay second location
Trip Release Characteristic
Time delay third location
Trip Release Characteristic
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 second location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 third location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
4 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At each pole
External Actuator Linkage Arrangement
One, two, three, and four linked
Internal Trip Release Configuration
Series trip first location
Internal Trip Release Configuration
Series trip second location
Internal Trip Release Configuration
Series trip third location
Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct second location and 12.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct first location and 12.000 at 200 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct third location and 12.000 at 200 pct third location
Inclosure Protection Type For Which Designed
Explosion proof and fungus resistant and moisture resistant
Frequency In Hertz
400.0 first location
Frequency In Hertz
400.0 second location
Frequency In Hertz
400.0 third location
Test Data Document
18876-+55629-002 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Thread Series Designator
Unc
Terminal Type And Quantity
8 threaded stud