These part numbers have the same form, fit, and function as radcal 9010
Item Number Cage
RADCAL 9010 4P061

Technical Definition

Radiac Set, also referenced with federal logistics item name code 07331 - A fixed number of components and/or items, not all having the same basic name, which are used to detect, measure and/or compute radioactivity. they may or may not indicate simultaneously.

Q & A

Part number RADCAL+9010
What are the historical prices for part number RADCAL+9010?
No pre-dated pricing for this NSN could be found.
Does this part number RADCAL+9010 have a shelf life?
No. There is no shelf life applicable for this part.
Does this part number RADCAL+9010 require Demilitarization?
Commerce control list items (ccli) - mutilation to the point of scrap required outside the united states. in the united states, mutilation requirement determined by the demil integrity code. dod trade security controls (tsc) required in the united state
Is part number RADCAL+9010 ITAR controlled?
Yes. This item is subject to the international traffic in arms regulations (ITAR).
What is the NSN for part number RADCAL+9010?
6665-01-515-7846
Who are the manufacturers of RADCAL+9010 and NSN 6665-01-515-7846?
  • Radcal Corporation An M D H Company (CAGE 4P061)

RADCAL 9010

Description: Radiac Set
Part Number RADCAL 9010 RADCAL 9010

Specification

porm 4 pct of reading, porm 1 digit, porm 2 times resolution; repeatability porm 1 pct of reading, porm 1 digit, porm 2 times resolution; auto temperature accuracy 2 pct; auto pressure accuracy 0.2 pct, plus 2 pct of reference pressure-ambient, optional specify opt-p; analog capture 0-5 v, 10khz, 12 bit analog to digital signal capture, 100 usec and 1.25 mv resolution over1 sec; playback to analog output; data available at the rs-232 port or anlaog out; timing 5 ms to 6.5 sec with 100usec resolution with porm 0.05 pct accuracy; exclusive of non-invasive detector; infrared remote allows full control from up to 10 m away, will go through lead glass

ALCD Usage Design
X-ray service, x-ray qa and compliance, x-ray acceptance testing, industrial applications, medical and health physics, therapy qa, secondary standards, nuclear applications, radiography, fluoroscopy, angiography, mammography; image intensifier; pulsed x-ray; cine; ct; dental; 137cs; 60co irradiator measurements; survey meter calibration; industrial x-ray, cables up to 300 feet; very low dose rates and very high dose rate applications, up to 107r/hr with special modification
ALSF Internal Battery Accommodation
Included
AMKD Indicator Type
Visual
AMRM Radiation Type And Function
X-rays detects
FEAT Special Features
Dfunctions auto zero; dose rate; max dose rate; dose; auto dose; pulsed,cine;lcd display test lcd display verification; battery test checks battery voltage; chamber voltage test checks bias voltage
FTLD Functional Description
Multipurpose dosemeters
SUPP Supplementary Features
Porm 4 pct of reading, porm 1 digit, porm 2 times resolution; repeatability porm 1 pct of reading, porm 1 digit, porm 2 times resolution; auto temperature accuracy 2 pct; auto pressure accuracy 0.2 pct, plus 2 pct of reference pressure-ambient, optional specify opt-p; analog capture 0-5 v, 10khz, 12 bit analog to digital signal capture, 100 usec and 1.25 mv resolution over1 sec; playback to analog output; data available at the rs-232 port or anlaog out; timing 5 ms to 6.5 sec with 100usec resolution with porm 0.05 pct accuracy; exclusive of non-invasive detector; infrared remote allows full control from up to 10 m away, will go through lead glass
National Stock Number (NSN): 6665-01-515-7846