Radio Frequency Interfere Filter

Model / MPN: RF10617 | NSN: 5915-00-156-0088
ITAR Registered seal

An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes filter, low pass and suppressor, ignition interference. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see filter, band suppression and filter, band pass. See also limiter, electrical noise.

Product Details
NATO Stock Number
5915-00-156-0088
Sold in multiples of
1 EA
DEMIL
DEMIL/MLI
Overall Length
3.938 inches
Overall Height
2.876 inches
Mounting Slot Width
0.140 inches
Body Length
3.500 inches
Body Width
1.375 inches
Body Height
2.000 inches
Vibration Resistance Range In Hertz
+10.0/+2000.0
Vibration Resistance Range In Hertz
+10.0 to 2000.0
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.000 inches
Operating Tempurature Range
-54.0/+90.0 degrees celsius
Operating Tempurature Range
-54.0 to 90.0 degrees celsius
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference 2nd function
Source Impedance Rating Per Function
50.0 ohms 5th radio interference 5th function
Load Impedance Per Function
50.0 ohms 1st radio interference
Load Impedance Per Function
50.0 ohms 3rd radio interference
Load Impedance Per Function
50.0 ohms 2nd radio interference
Load Impedance Per Function
50.0 ohms 4th radio interference
Load Impedance Per Function
50.0 ohms 5th radio interference
Load Impedance Per Function
50.0 ohms 2nd radio interference 2nd function
Load Impedance Per Function
50.0 ohms 4th radio interference 4th function
Power Line Frequency Rating Per Function In Hertz
420.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz
420.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz
420.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz
420.0 4th radio interference
Power Line Frequency Rating Per Function In Hertz
420.0 5th radio interference
Power Line Frequency Rating Per Function In Hertz
420.0 1st radio interference 1st function
Power Line Frequency Rating Per Function In Hertz
420.0 3rd radio interference 3rd function
Operating Current Rating Per Function In Amps
0.05 3rd radio interference
Operating Current Rating Per Function In Amps
0.05 4th radio interference
Operating Current Rating Per Function In Amps
0.05 5th radio interference
Operating Current Rating Per Function In Amps
5.0 1st radio interference
Operating Current Rating Per Function In Amps
5.0 2nd radio interference
Operating Current Rating Per Function In Amps
0.05 3rd radio interference 3rd function
Operating Current Rating Per Function In Amps
0.05 5th radio interference 5th function
Operating Current Rating Per Function In Amps
5.0 1st radio interference 1st function
Maximum Voltage Drop Per Function
1.5 volts ac 3rd radio interference
Maximum Voltage Drop Per Function
1.5 volts ac 4th radio interference
Maximum Voltage Drop Per Function
1.5 volts ac 5th radio interference
Maximum Voltage Drop Per Function
4.0 volts ac 1st radio interference
Maximum Voltage Drop Per Function
4.0 volts ac 2nd radio interference
Maximum Voltage Drop Per Function
1.5 volts ac 5th radio interference 5th function
Maximum Voltage Drop Per Function
4.0 volts ac 2nd radio interference 2nd function
Principal Circuitry Type Per Function
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function
Inductance-capacitance 4th radio interference
Principal Circuitry Type Per Function
Inductance-capacitance 3rd radio interference
Principal Circuitry Type Per Function
Inductance-capacitance 5th radio interference
Principal Circuitry Type Per Function
Inductance-capacitance 4th radio interference 4th function
Principal Circuitry Type Per Function
Inductance-capacitance 2nd radio interference 2nd function
Input Terminal Manufacturer Code
96906
Input Terminal Identification
Ms3112e128p
Mounting Facility Screw Thread Series Designator
Unc
Inclosure Type
Encased
Mounting Facility Type And Quantity
2 slot
Mounting Facility Type And Quantity
4 threaded hole
Mounting Facility Type And Quantity
2 slot 1st function
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
Functional Terminal Type And Quantity
1 turret ground 3rd function
Functional Terminal Type And Quantity
5 turret output 2nd function
Operating Voltage Rating And Type Per Function
132.0 volts ac 2nd radio interference 1st function
Operating Voltage Rating And Type Per Function
132.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function
132.0 volts ac 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function
132.0 volts ac 4th radio interference 4th function
Operating Voltage Rating And Type Per Function
132.0 volts ac 5th radio interference 5th function
Thread Size
0.112 inches
Body Surface Treatment
Tin
Style Designator
Rectangular terminal/terminals on two surfaces

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping
RF10617 Cross Reference
  • 95G3253-1-1
  • 95G3253-1-1
  • 95G3253-1
  • FC543
  • 95G3253-1
  • 95G3253-1