Request Pricing & Availability

NSN: 5925-00-001-5748
Part Number(s):
Quantity:
Company:
Name & Email:
Phone:
Order Terms | Privacy Policy    

Cross Reference These part numbers have the same form, fit, and function of upg66-1-62-153-01

Item Number Cage
CB60HZ15A 81541
UPG66-1-62-153-01 81541
000564-1 90536
UPG66-2224-1 81541
59000564-1 50544

Characteristic Codes UPG66-1-62-153-01 spec. code meanings

Code Translation
CPRW Denotes the action imparted by actuator operation.
CPRX An indication of the designated position of the actuator.
ADAQ A measurement of the longest dimension of the body, in distinction from width.
AAQL The style designation indicating the configuration that most nearly corresponds to the appearance of the body.
ADAT A measurement taken at right angles to the length of the body, in distinction from thickness.
ADTV The element, compound, or mixture of which the case is fabricated, excluding any surface treatment.
AEBP The center to center distance between terminals parallel to the length of the item.
AEBQ The center to center distance between terminals parallel to the width of the item.
CPRH Indicates the type of electrical condition that will cause the device to trip.
AEBY The distance between centerlines of mounting facilities parallel to the length of the item.
AEHA The distance between centerlines of mounting facilities parallel to the width of the item.
FREQ The cycles per second /hertz/ of the alternating current.
CPLM The maximum current load that each pole is rated to carry continuously.
CPRG Indicates the type and value of the maximum short circuit current that the item will successfully interrupt, per pole, at the specified rated voltage, expressed in amperes.
AXHR Indicates the type and number of facilities by which the item is mounted.
CQJX A designation that is used for the purpose of general identification of the thread.
CPRF Indicates the type and value of operating voltage for which each pole is designed to operate, expressed in volts.
CPSM The basic internal electrical configuration of the trip mechanism.
CPRR Indicates the type of mechanism provided for tripping main contacts.
CPRT Indicates the type and number of actuators provided for manual control.
CPRQ The means provided to reposition the mechanism so that the device is ready to function.
AKPX The number of poles included in the item.
TTQY Indicates the type and number of terminals for providing electrical connection.
CMLP The number of threads on the item per linear inch measured on a line parallel to the thread axis.
THSD A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
CQWN The length of time, expressed in seconds, that an overload may exist before the device will trip at a specified continuous current.
CPRL Denotes the type of trip release action.
CPRJ The means by which the trip mechanism is released.
CPRN The continuous current rating per pole at which the device must trip in a specified time, expressed in percent.

UPG66-1-62-153-01 Circuit Breaker

Mfr. Cage 50544

Specification

Thread Size: 9/64"

CPRW Actuator Function
Trip-reset
CPRX Actuator Position Designation
At pole one
ADAQ Body Length
2.000 inches
AAQL Body Style
Multipole-single actuator type
ADAT Body Width
1.500 inches
AJEC Boss Height
0.130 inches
ADTV Case Material
Plastic
AEBP Center To Center Distance Between Terminals Parallel To Length
1.530 inches
AEBQ Center To Center Distance Between Terminals Parallel To Width
0.750 inches
CPRH Circuit Protection Type
Overcurrent all locations
AEBY Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches
AEHA Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches
FREQ Frequency In Hertz
60.0 all locations
CPLM Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations
CPRG Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
AXHR Mounting Facility Type And Quantity
4 threaded hole
AJWX Mounting Surface To Terminal End Distance
2.000 inches maximum
CQJX Nominal Thread Size
0.138 inches
CPRF Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
CPSM Internal Trip Release Configuration
Series trip all locations
CPRR Main Contact Tripping Mechanism Type
Trip free
CPRT Manual Actuator Type And Quantity
1 toggle
CPRQ Reset Method
Manual
AKPX Pole Quantity
2
TTQY Terminal Type And Quantity
4 screw
CMLP Thready Qty Per Inch (tpi)
32
THSD Thread Series Designator
Unc
CQWN Trip Delay Time In Seconds Per Rated Continuous Current
2.200 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations
CPRL Trip Release Characteristic
Time delay all locations
CPRJ Trip Release Method
Magnetic-hydraulic all locations
CPRN Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations

Technical Definition

Circuit Breaker, also referenced with federal logistics item name code 00136 - A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
National Stock Number (NSN) 5925-00-001-5748

Last Modified: 02/14/2017