Worldwide distributor of NSN parts and consumables located in the USA.
A small, metallic tube closed at one end and filled with high explosives used to detonate demolition and explosive charges/items. Non-electric blasting caps can be initiated and/or assembled with fuse, blasting, time, shock tube, or cord, detonating. Electric blasting caps have wires and are initiated from an electrical current, provided from sources such as a blasting machine. They may come with devices to simplify use with other items, such as a holder, blasting cap or a demolition bar.
Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.
Safety fuses; detonating fuses; percussion or detonating caps, igniters; electric detonators
Safety fuses; detonating fuses; percussion or detonating caps; ignitors; electric detonators
Parts for military-type goods
Y - Indicates information is in the hazardous materials information resource system (hmirs).
PMICA - Item does not contain precious metal.
ADPE- Represents items with no adp components
CRITL- The item does not have a critical feature such as tolerance, fit restrictions or application. nuclear hardness properties have not been determined (not valid for input).
064300 - Explosives: ammo or cartridges sub1
3 - Ammunition (all types) including inert component parts. when the primary hazard of an ammunition item is a chemical (irritant, c
4 - Moderate sensitivity, category iii, aa&e, unclassified
417 - Blasting caps, detonaters, at mine fuzes (chemical), etc. (viii)
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
D - 200.0
D - 200.0
I - Explosives, class a, un class 1; maximum hazard
Questions & Answers: |
|
What are the historical prices recorded for this stock number? | |
Historical data shows pricing from $11.26 to $18.77.. | |
Does NSN 1375-01-192-9174 have a shelf life? | |
No. There is no shelf life applicable for this NSN. | |
What NATO entities are users of this NSN? | |
Department Of The Army, Department Of The Air Force, U.s. Marine Corps, Department Of The Navy, Nadb (nato Ammunition Data Base), Republic Of Korea, Greece, and Turkey | |
What is the NIIN of NSN 1375-01-192-9174? | |
011929174 or 01-192-9174 | |
Does NSN 1375-01-192-9174 require demilitarization? | |
Yes - ITAR Controlled | |
What is the most recent solicitation for NSN 1375-01-192-9174? | |
No solicitations for this NSN. | |
When was this national stock number assigned to the federal catalog? | |
Oct 27, 1984 |
Ld50 lc50 mixture: not known
routes of entry: inhalation: no skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: no exposure to chemical hazards
anticipated with normal handling procedures.Accidental detonation
of an explosive device can cause lacerations,punctures and/or other
traumatic injury.
explanation of carcinogenicity: none
effects of overexposure: no exposure to chemical hazards anticipated
with normal handling procedures.
medical cond aggravated by exposure: not known
First aid: eyes: flush with large amounts of water for at least 15
minutes . Inhalation: if detonation fumes are inhaled,remove to
fresh air.If breathing stops,give artificial respiration.
Boiling pt: b.P. Text: not known
melt/freeze pt: m.P/f.P text: not known
decomp temp: decomp text: not known
vapor pres: not known
vapor density: not known
spec gravity: not known
evaporation rate & reference: not known
solubility in water: not known
appearance and odor: round metal cup,242 inch diameterx2.29 inch long.
Stability indicator/materials to avoid: no
corrosives
stability condition to avoid: excessive heat (>160f) from sources such
as flame producing devices,impact,friction & electrical impulse.
hazardous decomposition products: as a result of detonation only: lead
oxides,nitrogen oxides,carbon monoxide.
Waste disposal methods: disposal must be in accordance with
federal,state,and local regulations.Coordinate with supporting
installation and/or macom environmental office prior to disposal
.Consult mfr for best disposal method.Disposal governed by rcra,40
cfr 260-271.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: rdx (cyclonite).943 mg spec.Mil-r-398.
cas: 121-82-4
rtecs #: xx9450000
other rec limits: none recommended
osha pel: 1.5 mg/m3,skin
acgih tlv: 1.5 mg/m3,skin
ingred name: lead azide.270 mg spec.Mil-l-3055.Osha pel & acgih tlv for
inorganic lead fumes & dusts.
cas: 13424-46-9
rtecs #: of8650000
other rec limits: none recommended
osha pel: 0.05 mg(pb)/m3
acgih tlv: 0.15 mg(pb)/m3
ingred name: ignition.118 mg dwg.12624433.
other rec limits: none recommended