Worldwide distributor of NSN parts and consumables located in the USA.
Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.
Undercarriages and parts thereof, for use in military aircraft
Undercarriages and parts thereof for aircraft
Parts for military-type goods
Y - Indicates information is in the hazardous materials information resource system (hmirs).
PMICA - Item does not contain precious metal.
011760 - Aircraft/aircraft part viz:
671 - Aircraft parts, to include test/tool sets and equipment (other than armament systems)
9 - Other or no special handling required (sh)
A - Supplies and equipment for aircraft and aerial targets, including aircraft and maintenance parts, aircraft accessories, aircraft
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
D - 200.0
Z - No special type of cargo code applicable
Questions & Answers: |
|
What are the historical prices recorded for this stock number? | |
Historical data shows pricing from $4,216.19 to $7,026.99.. | |
Does NSN 1630-01-333-6799 have a shelf life? | |
No. There is no shelf life applicable for this NSN. | |
What NATO entities are users of this NSN? | |
Department Of The Navy, Finland, Spain, Malaysia, Australia, and Canada | |
What is the NIIN of NSN 1630-01-333-6799? | |
013336799 or 01-333-6799 | |
Does NSN 1630-01-333-6799 require demilitarization? | |
Yes - ITAR Controlled | |
What is the most recent solicitation for NSN 1630-01-333-6799? | |
No solicitations for this NSN. | |
When was this national stock number assigned to the federal catalog? | |
Feb 08, 1991 |
ld50 lc50 mixture: ld50 (oral, rat) is not known.
route of entry inds - inhalation: yes
skin: no
ingestion: no
carcinogenicity inds - ntp: no
iarc: no
osha: no
effects of exposure: target organs: eye, skin, respiratory & gi tracts.
acute- the part is non-hazardous as shipped. Dust/fumes may cause eye &
skin irritation. Inhalation of dust/fumes may cause upper respiratory tract
ir ritation. Ingestion may cause gastrointestinal tract irritation. Chronic-
may cause pneumoconiosis.
explanation of carcinogenicity: none
signs and symptions of overexposure: irritation, discomfort, cough
medical cond aggravated by exposure: persons with pre-existing skin disorders,
eye problems or impaired respiratory function may be more susceptible to the
effects of this product.
first aid: get medical attention if symptoms persist. Eyes: immediately flush
with water for 15 minutes. Hold eyelids open. Skin: wash with soap &
water. Inhaled: remove to fresh air. Provide cpr/oxygen if necessar y. Oral: do
not induce vomiting except on advice of competent medical personnel. If
conscious, drink milk or water. Keep person warm & quiet. Never give
anything by mouth to an unconscious person.
hcc: n1
nrc/state lic no: not relevant
b.P. Text: 8690f,4810c
m.P/f.P text: 6512f,3600c
decomp text: unknown
spec gravity: 1.60 - 1.80
viscosity: not relevant
evaporation rate & reference: not relevant
solubility in water: insoluble
appearance and odor: black solid - no odor
product id: aircraft carbon disk brakes parts,2610304
cage: 55284
company name: honeywell intl inc, aircraft landing system als
street: 3520 westmoor street
city: south bend in
zipcode: 46628-1373
health emergency phone: 219-231-2000
label required ind: y
date of label review: 11/19/1996
status code: c
mfg label no: unknown
label date: 11/19/1996
origination code: f
eye protection ind: yes
skin protection ind: yes
signal word: caution
health hazard: slight
contact hazard: slight
fire hazard: none
=======================================================
responsible party cage: 55284
trans id no: 126361
product id: aircraft carbon disk brakes parts,2610304
msds prepared date: 07/01/1996
review date: 11/19/1996
mfn: 1
radioactivity: not relevant
net unit weight: unknown
multiple kit number: 0
review ind: y
unit of issue: ea
container qty: 0
type of container: unknown
additional data: not regulated by dot for transportation, per msds.
Hazard and precautions: target organs: eye, skin, respiratory & gi tracts.
acute- product is non-hazardous as shipped. Dust/fumes may cause eye, skin,
upper respiratory tract irritation. Ingestion may cause gi tract irritatio n.
chronic- may cause pneumoconiosis. Store in cool, ventilated area. Sweep up
spill. Place in appropriate container for disposal. First aid- get medical
attention if symptoms persist. Eyes: immediatel y flush with water for 15
minutes. Hold eyelids open. Skin: wash with soap & water. Inhaled: remove
to fresh air. Provide cpr/oxygen if needed. Oral: do not induce vomiting
except on advice of physician. if conscious, drink milk/water. Call
physician.
spill release procedures: sweep up or shovel spill. Avoid creating dust. Place
spill in appropriate container for later disposal. Ventilate area and wash
spill site with water.
neutralizing agent: not relevant
waste disposal methods: dispose of in compliance with all local, state and
federal regulations. Recycle if possible.
handling and storage precautions: store in cool place. Use in ventilated area.
keep out of reach of children.
other precautions: caution! In closed containers carbon monoxide may be
present. Do not raise dust. Avoid contact with eyes or skin. Avoid inhalation
of dust or fume. Wash thoroughly after handling material. For industr ial use
only. Do not ingest.