A coated or uncoated filler metal or an uncoated nonfiller material in wire or solid rod form. It is used in welding where the fusing or melting heat is supplied through the medium of an electric arc wherein the rod serves as carrier of the electric current. For a collection of welding electrodes, see welding electrode set. Excludes electrode, cutting, solid.
Solicitation | Return by Date | Buyer Code | Quantity |
---|---|---|---|
SPE8E620T1250 | 2019-12-12 | PEPCC | 49 CO |
SPE8E620T0772 | 2019-11-25 | PEPCC | 46 CO |
SPE8E620T0295 | 2019-10-21 | PEPCC | 54 CO |
Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.
Coated electrodes of base metal, for electric arc-welding
Wire, rods, electrodes, etc., of base metal or of metal carbides, flux coated for soldering, etc, ; agglomerated base metal powder for metal spraying
Finished metal shapes
Y - Indicates information is in the hazardous materials information resource system (hmirs).
PMICU - Precious metal content is unknown
CRITL- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
197060 - Welding bars/rods/wire
732 - Tools, hand and portable, electric
9 - Other or no special handling required (sh)
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
B - Construction materials: includes paint and related materials, prefabricated building, wood products, metal and composition mater
W - Rating variable
Z - No special type of cargo code applicable
Questions & Answers: |
|
What are the historical prices recorded for this stock number? | |
Historical data shows pricing from $419.58 to $699.30.. | |
Does NSN 3439-00-262-2598 have a shelf life? | |
No. There is no shelf life applicable for this NSN. | |
What NATO entities are users of this NSN? | |
Department Of The Army, Department Of The Air Force, U.s. Marine Corps, Department Of The Navy, Government Printing Office, General Services Administration, Tennessee Valley Authority, Spain, Republic Of Korea, and Greece | |
What is the NIIN of NSN 3439-00-262-2598? | |
002622598 or 00-262-2598 | |
Does NSN 3439-00-262-2598 require demilitarization? | |
Yes - ITAR Controlled | |
What is the most recent solicitation for NSN 3439-00-262-2598? | |
Solicitation SPE8E620T1250 for qty 49 on 12/02/2019 | |
When was this national stock number assigned to the federal catalog? | |
Jan 01, 1961 |
Routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: long term exposure to welding fume,
gases or dust may contribute to pulmonary irritation or
pneumoconiosis. repeated or prolonged contact may irritate the
throat.
effects of overexposure: short term exposure to welding fume may result
in disconfort, dizziness, nausea, or dryness. long term exposure
to welding fume, gases or dust may contribute to pulmonary
irritation or pneumoconiosis .
medical cond aggravated by exposure: individuals with impaired pulmonary
functions or illness may have symptoms exacerbated by fume
irritants.
First aid: remove from dust or fume exposure. If breathing has stopped,
perform artificial respiration. Summon medical aid immediately.
Hcc: n1
Stability indicator/materials to avoid: yes
none specified by manufacturer.
stability condition to avoid: none specified by manufacturer.
hazardous decomposition products: welding and brazing fumes and gases
cannot be classified simply.
Waste disposal methods: dispose of in accordance with local, state, and
federal regulations.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: aluminum (sara iii)
cas: 7429-90-5
rtecs #: bd0330000
fraction by wt: balance
other rec limits: none recommended
osha pel: 15mg/m3 dust/5 fume
acgih tlv: 10mg/m3 dust; 9192
ingred name: silicon
cas: 7440-21-3
rtecs #: vw0400000
fraction by wt: 5%
other rec limits: none recommended
osha pel: 15 mg/m3 tdust
acgih tlv: 10 mg/m3 tdust; 9293
ingred name: aluminum fluoride
cas: 7784-18-1
rtecs #: bd0725000
fraction by wt: 1-11%
other rec limits: none recommended
ingred name: lithium fluoride
cas: 7789-24-4
rtecs #: oj6125000
fraction by wt: 1-11%
other rec limits: none recommended
ingred name: magnesium fluoride
cas: 7783-40-6
rtecs #: om3325000
fraction by wt: 1-11%
other rec limits: none recommended
ingred name: potassium chloride
cas: 7447-40-7
rtecs #: ts8050000
fraction by wt: 1-11%
other rec limits: none recommended
ingred name: potassium fluoride
cas: 7789-23-3
rtecs #: tt0700000
fraction by wt: 2-11%
other rec limits: none recommended
ingred name: sodium chloride
cas: 7647-14-5
rtecs #: vz4725000
fraction by wt: 1-11%
other rec limits: none recommended
Ld50 lc50 mixture: tlv: welding fume is 5 mg/m3
routes of entry: inhalation: yes skin: yes ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: electric arc-welding may create
fumes/gases can be dangerous. Arc rays can injure eyes & burn skin.
electric shock can kill.
explanation of carcinogenicity: carcinogenic: na.
effects of overexposure: short term to welding fumes-dizziness, nausea,
dryness & irrt of nose/eyes/throat, chest tightness, fever,
allergic reaction. Lonter-siderosis, believed to affect pulmonary
function.
medical cond aggravated by exposure: pulmonary function.
First aid: call for medical aid. employ first aid techniques
recommended by american red cross.
Hcc: n1
appearance and odor: coated metal rod. No odor.
Stability indicator/materials to avoid: yes
none.
stability condition to avoid: none unless otherwise specified.
hazardous decomposition products: (see supplem)reasonbly expected
fume: primary oxides of fe,2nd oxides of
cr,ni,mn,si,mo.Gas: co,co2,ozone,nitrogen oxides.
Waste disposal methods: prevent waste from contaminating surrounding
enviro.Discard any product residue,disposable cntnr or liner in
envirom acceptable manner,in full complaiance with local, state and
federal regulations.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: aluminum (sara iii)
cas: 7429-90-5
rtecs #: bd0330000
fraction by wt: 70-80%
other rec limits: none recommended
osha pel: 15mg/m3 dust/5 fume
acgih tlv: 10mg/m3 dust; 9192
ingred name: niobium (also called columbium)
cas: 7440-03-1
fraction by wt: 1-11%
other rec limits: none recommended
ingred name: aluminum fluoride
cas: 7784-18-1
rtecs #: bd0725000
fraction by wt: 1-11%
other rec limits: none recommended
osha pel: 2.5 ppm f
acgih tlv: 2.5 mg f/m3
ingred name: lithium fluoride
cas: 7789-24-4
rtecs #: oj6125000
fraction by wt: 1-11%
other rec limits: none recommended
osha pel: 2.5 mg/m3
acgih tlv: 2.5 mg/m3
ingred name: magnesium fluoride
cas: 7783-40-6
rtecs #: om3325000
fraction by wt: 1-11%
other rec limits: none recommended
osha pel: 2.5 mg/m3
acgih tlv: 2.5 mg/m3
ingred name: potassium chloride
cas: 7447-40-7
rtecs #: ts8050000
fraction by wt: 1-11%
other rec limits: none recommended
ingred name: potassium fluoride
cas: 7789-23-3
rtecs #: tt0700000
fraction by wt: 2-12%
other rec limits: none recommended
ingred name: sodium chloride
cas: 7647-14-5
rtecs #: vz4725000
fraction by wt: 1-11%
other rec limits: none recommended
Reports of carcinogenicity: ntp: unknown iarc: unknown osha: yes
health hazards acute and chronic: electric arc-welding may create one or
more of the following health hazards: fumes and gases can be
dangerous to your health. Arc rays can injure eyes and burn skin.
electric shock can kill. Short ter m overexposure to welding fumes
may result in discomfort such as: dizziness, nausea, dryness or
irritation of nose, throat, eyes, tightness in chest, fever and
allergic reactions. Long term (chronic) overexposures to welding
fumes may lead to siderosis (iron deposit in lungs) and is believed
by some investigators to affect pulmonary function. Chromium
compounds are required to be considered carcin ogenic by osha.
explanation of carcinogenicity: chromium compounds are considered
carcinogenic by osha.
effects of overexposure: short term overexposure to welding fumes may
result in discomfort such as: dizziness, nausea, dryness or
irritation of nose, throat, eyes, tightness in chest, fever and
allergic reactions. Long term ( chronic) overexposures to welding
fumes may lead to siderosis (iron deposit in lungs) and is believed
by some investigators to affect pulmonary function.
First aid: remove to fresh air, obtain medical attention. Employ first
aid techniques recommended by the american red cross.
Hcc: n1
appearance and odor: each electrode: metal rod; 0.125 in. Diameter by 14
inches long.
Stability indicator/materials to avoid: yes
none.
stability condition to avoid: none: unless otherwise specified.
hazardous decomposition products: composition and quality of welding
fumes and gases are dependent on the metal welded, the process,
procedure, and electrodes used, coatings on welded metal (paint,
plating, galvanizing), (contd. Below)
Waste disposal methods: prevent waste from contaminating surrounding
environment. Discard any product residue, disposable container or
liner in an environmentally acceptable manner, in full compliance
with federal, state, an d local regulations.
Ingred name: aluminum
cas: 7429-90-5
rtecs #: bd0330000
osha pel: 15 mg/m3
acgih tlv: 10 mg/m3 dust
ingred name: copper
cas: 7440-50-8
rtecs #: gl5325000
osha pel: 1 mg/m3 fume
acgih tlv: 0.2 mg/m3 fume
epa rpt qty: 5000 lbs
dot rpt qty: 5000 lbs
ingred name: iron
cas: 1309-37-1
rtecs #: no7400000
osha pel: 10 mg/m3 fume
acgih tlv: 5 mg/m3 fume
ingred name: magnesium
cas: 1309-48-4
rtecs #: om3850000
osha pel: 15 mg/m3 fume
acgih tlv: 10 mg/m3 fume
ingred name: manganese
cas: 7439-96-5
rtecs #: oo9275000
osha pel: c 5 mg/m3
acgih tlv: 1 mg/m3 fume
ingred name: silicon
cas: 7440-21-3
rtecs #: vw0400000
osha pel: 15 mg/m3
acgih tlv: 10 mg/m3 t dust
ingred name: tin
cas: 7440-31-5
rtecs #: xp7320000
osha pel: 2.0 inorganic
acgih tlv: 2 mg/m3
ingred name: zinc
cas: 1314-13-2
rtecs #: zh4810000
osha pel: 5 mg/m3 fume
acgih tlv: 5 mg/m3 fume