Worldwide distributor of NSN parts and consumables located in the USA.
Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.
Y - Indicates information is in the hazardous materials information resource system (hmirs).
PMICA - Item does not contain precious metal.
CRITL- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
050390 - Compounds welding
635 - Chemicals, other than drugs or sundries
9 - Other or no special handling required (sh)
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
C - Chemical corps items and all other chemicals not covered in other classificatons. note: when an item has a chemical proper shipp
T - 55.0
W - Corrosive materials, un class 8 (corrosive label)
Questions & Answers: |
|
What are the historical prices recorded for this stock number? | |
Historical data shows pricing from $40.86 to $68.11.. | |
Does NSN 3439-00-406-3044 have a shelf life? | |
No. There is no shelf life applicable for this NSN. | |
What NATO entities are users of this NSN? | |
Defense Logistics Agency | |
What is the NIIN of NSN 3439-00-406-3044? | |
004063044 or 00-406-3044 | |
Does NSN 3439-00-406-3044 require demilitarization? | |
Yes - ITAR Controlled | |
What is the most recent solicitation for NSN 3439-00-406-3044? | |
No solicitations for this NSN. | |
When was this national stock number assigned to the federal catalog? | |
Apr 10, 1970 |
Effects of overexposure: causes burns
First aid: flush skin or eyes with plenty of water for at least 15 min.
while removeing contaiminated clothing & shoes.Call dr.
Hcc: c3
spec gravity: >1.
solubility in water: appreciable
appearance and odor: gray crystalline solid with no odor.
Stability indicator/materials to avoid: yes
acids
hazardous decomposition products: hydrogen chloride,zinc
oxide,ammonia,ammonium chloride
Waste disposal methods: scoop up & put into chemical waste
container.Sweep area.Flush residue with water to chemical sewer.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: solder(40% tin,60% lead)
fraction by wt: 50%
ingred name: zinc ammonium chloride
fraction by wt: 50%
Ld50 lc50 mixture: ld50 (oral rat) is unknown.
routes of entry: inhalation: yes skin: no ingestion: yes
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: acute- heating above 900f can generate
lead fumes which is toxic if inhaled. Zinc chloride can burn
gastrointestinal tract if ingested. Zinc chloride is corrosive. May
cause burns if eye contact occur s. Can cause skin irritation.
chronic- unknown. Target organs: eyes, skin, respiratory and
gastrointestinal tracts.
explanation of carcinogenicity: none
effects of overexposure: eye, skin, respiratory tract and
gastrointestinal tract irritation, eye burns
medical cond aggravated by exposure: persons with pre-existing skin
disorders, eye problems or impaired respiratory function may be
more susceptible to the effects of this product.
First aid: call a doctor if symptoms persist. Eye/skin: immediately flush
with water for 15 minutes. Hold eyelids open. Inhaled: remove to
fresh air. Provide cpr/oxygen if needed. Oral: get medical attention
immedi ately.
Hcc: c1
nrc/state lic num: not relevant
spec gravity: 2
evaporation rate & reference: not relevant
solubility in water: 50%
appearance and odor: gray powder. No odor.
percent volatiles by volume: 0
Stability indicator/materials to avoid: yes
strong acids
stability condition to avoid: heating above 900f.
hazardous decomposition products: hydrogen chloride, zinc oxide,
ammonia, ammonium chloride, lead fumes
Waste disposal methods: dispose of in accordance with all local, state
and federal regulations. National response center # (800) 424-8802.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: lead
cas: 7439-92-1
rtecs #: of7525000
fraction by wt: 14%
other rec limits: none specified
osha pel: 0.05 mg/m3
acgih tlv: 0.15 mg/m3 dust 9293
epa rpt qty: 1 lb
dot rpt qty: 1 lb
ingred name: zinc chloride
cas: 7646-85-7
rtecs #: zh1400000
fraction by wt: 46%
other rec limits: none specified
osha pel: 1 mg/m3/2 stel
acgih tlv: 1 mg/m3/2stel fume93
epa rpt qty: 1000 lbs
dot rpt qty: 1000 lbs