Worldwide distributor of NSN parts and consumables located in the USA.
An item used as a replacement cartridge for a demineralizer, water, ion exchange.
Solicitation | Return by Date | Buyer Code | Quantity |
---|---|---|---|
SPE8E921T2303 | 2021-04-29 | PEPCA | 745 EA |
SPE8E919T3661 | 2019-09-06 | PEPCA | 783 EA |
SPE8E919T2040 | 2019-04-11 | PEPCA | 654 EA |
SPE8E919T0035 | 2018-10-15 | PEPCA | 509 EA |
SPE8E918T3386 | 2018-07-23 | PEPCA | 641 EA |
SPE8E918T2727 | 2018-05-29 | PEPCA | 693 EA |
SPE8E918T2513 | 2018-05-14 | PEPCA | 266 EA |
SPE8E918T1238 | 2018-02-01 | PEPCA | 43 EA |
SPE8E918T0730 | 2017-12-11 | PEPCA | 368 EA |
SPE8E917T3511 | 2017-10-10 | PEPCA | 875 EA |
The last inventory check on this NSN was done on 01/08/2024. Due to rapid changes in inventory this may not be the current stock qty.
Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.
Parts of machinery and apparatus for filtering or purifying water
Parts of filtering or purifying machinery and apparatus
Food, tobacco machinery
Y - Indicates information is in the hazardous materials information resource system (hmirs).
PMICA - Item does not contain precious metal.
CRITL- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
121265 - Filters/purifiers water etc sub2
72E - Engineer and material handling equipment, test/tool sets and equipment
9 - Other or no special handling required (sh)
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
P - 77.5
V - Trailers, vehicles, machinery, shop and warehouse equipment and supplies including special tools and equipment, ground servicing
Z - No special type of cargo code applicable
Questions & Answers: |
|
What are the historical prices recorded for this stock number? | |
Historical data shows pricing from $92.38 to $153.97.. | |
Does NSN 4610-00-363-5770 have a shelf life? | |
No. There is no shelf life applicable for this NSN. | |
What NATO entities are users of this NSN? | |
Department Of The Army, Department Of The Air Force, U.s. Marine Corps, Department Of The Navy, Federal Aviation Administration, Austria, Poland, Brazil, Spain, Singapore, Saudi Arabia, Malaysia, Australia, Belgium, Canada, New Zealand, Germany, Republic Of Korea, United Kingdom, Netherlands, Portugal, Italy, Denmark, Norway, Greece, Turkey, and Nato Maintenance and Supply Agency | |
What is the NIIN of NSN 4610-00-363-5770? | |
003635770 or 00-363-5770 | |
Does NSN 4610-00-363-5770 require demilitarization? | |
Yes - ITAR Controlled | |
What is the most recent solicitation for NSN 4610-00-363-5770? | |
Solicitation SPE8E921T2303 for qty 745 on 04/27/2021 | |
When was this national stock number assigned to the federal catalog? | |
Feb 22, 1974 |
Ld50 lc50 mixture: none specified by manufacturer.
routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: inhal: carbon dust may cause temporary
respiratory discomfort.
explanation of carcinogenicity: not relevant
effects of overexposure: inhale: respiratory discomfort.
medical cond aggravated by exposure: none specified by manufacturer.
First aid: eye: flush with copious quantities of water for 15 minutes,
call md. Skin: wash thoroughly with water. Inhale: remove to fresh
air, get md. Ingest: get md.
Spec gravity: 1.8-2.1
ph: 5.-8.
appearance and odor: black granules, odorless
Stability indicator/materials to avoid: yes
none specified by manufacturer.
stability condition to avoid: co*2, co
hazardous decomposition products: co*2, co
Waste disposal methods: disposal of material, its rinsings or spill
residues must be i/a/w federal, state and local regulations.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: carbon
Ld50 lc50 mixture: none specified by manufacturer.
routes of entry: inhalation: no skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: eye: can cause eye irritation. Skin: may
cause skin irritation.
explanation of carcinogenicity: not relevant
effects of overexposure: none specified by manufacturer.
medical cond aggravated by exposure: none specified by manufacturer.
First aid: eye: flush eyes with copious quantities of water for 15 min.
see md. Skin: flush with water.
Spec gravity: 1.1
ph: 9-11
evaporation rate & reference: 1
solubility in water: negligible
appearance and odor: light spherical beads slight trimethylamine odor.
percent volatiles by volume: 55-70%
Stability indicator/materials to avoid: yes
avoid contact with strong oxidizing agents, nitric acid.
stability condition to avoid: temperatures above 400f.
hazardous decomposition products: co, co*2, styrene, n(ch*3)*3, ammonia,
so*2
Waste disposal methods: disposal of material, its rinsings or spill
residues must be i/a/w federal, state and local regulations.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: anion exchange polymer
fraction by wt: 44-56%
ingred name: water
fraction by wt: 44-56%
Ld50 lc50 mixture: none specified by manufacturer.
routes of entry: inhalation: no skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: eye: can cause eye irritation. May
cause skin irritation.
explanation of carcinogenicity: not relevant
effects of overexposure: none specified by manufacturer.
medical cond aggravated by exposure: none specified by manufacturer.
First aid: eye: flush eyes with copious quantities of water for 15
minutes. Get md. Skin: flush with water.
Spec gravity: 1.1-1.3
ph: 6-8
evaporation rate & reference: 1
solubility in water: negligible
appearance and odor: mixture of dark and light spherical beads, odorless
percent volatiles by volume: 50-60%
Stability indicator/materials to avoid: yes
contact with strong oxidizing agents, nitric acid.
stability condition to avoid: temperatures above 400f.
hazardous decomposition products: co, co*2, divinylbenzene, styrene,
so*2, so*3, n(ch*3)*3, nh*3
Waste disposal methods: disposal of this material, its rinsings or spill
residues must be i/a/w all applicable federal, state and local
regulations.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: cation exchange polymer
cas: 69011-20-7
fraction by wt: 20-25%
ingred name: water
cas: 69011-20-7
fraction by wt: 50-60%
ingred name: anion exchange polymer
cas: 69011-20-7
fraction by wt: 20-30%
Ld50 lc50 mixture: none specified by manufacturer.
routes of entry: inhalation: no skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: resin is a strongly alkaline material.
eye contact: may cause mechanical irritation like other foreign
bodies. Mfr lists ingestion as a route of entry.
explanation of carcinogenicity: not relevant
medical cond aggravated by exposure: none specified by manufacturer.
First aid: eye: flush with water for at least 15 minutes. Get md if
irritation persists. Ingest: call md immediately . Inhal: remove to
fresh air. Support breathing (give o*2/artf resp) .
Melt/freeze pt: m.P/f.P text: 50% water
spec gravity: 1.1
solubility in water: negligible
appearance and odor: white spherical beads - amine odor.
Stability indicator/materials to avoid: yes
avoid contact with concentrated nitric acid, or strong oxidizing
agents.
stability condition to avoid: avoid temperatures over 60c (140f).
hazardous decomposition products: nh*3, ch*3, nh*2 and related amines,
co, co*2, styrene, divinylbenzene.
Waste disposal methods: except where odor is objectional, this material
can be disposed of as ordinary trash.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: ion exchange resin
fraction by wt: 100%