Worldwide distributor of NSN parts and consumables located in the USA.
Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.
Y - Indicates information is in the hazardous materials information resource system (hmirs).
PMICA - Item does not contain precious metal.
CRITL- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Questions & Answers: |
|
What are the historical prices recorded for this stock number? | |
No pre-dated pricing for this NSN could be found. | |
Does NSN 5350-01-028-5203 have a shelf life? | |
No. There is no shelf life applicable for this NSN. | |
What NATO entities are users of this NSN? | |
No recorded entities for this stock number. | |
What is the NIIN of NSN 5350-01-028-5203? | |
010285203 or 01-028-5203 | |
Does NSN 5350-01-028-5203 require demilitarization? | |
Yes - ITAR Controlled | |
What is the most recent solicitation for NSN 5350-01-028-5203? | |
No solicitations for this NSN. | |
When was this national stock number assigned to the federal catalog? | |
Oct 04, 1976 |
Routes of entry: inhalation: yes skin: no ingestion: yes
reports of carcinogenicity: ntp: yes iarc: yes osha: no
health hazards acute and chronic: acute: prolonged overexposure to
respirable silica above the tlv may cause scarring of the lungs.
prolonged inhalation of lead carbonate dust over the tlv limit or
ingestion of the compound can cause acute & chronic over exposure
symptoms.
explanation of carcinogenicity: lead chromate is listed as a suspected
carcinogen by ntp and iarc.
effects of overexposure: coughing, shortness of breath, asthma,
emphysema, gastroenteritis.
medical cond aggravated by exposure: none.
First aid: inhalation: remove to fresh air. Give mouth-to-mouth
resuscitation if not breathing. Get medical attention immediately.
eye: immediately flush with running water for 15 minutes while
holding lids open . Get medical attention immediately. Skin: wash
with soap & water. Remove contaminated clothing. Ingestion: do not
induce vomiting. Nothing by mouth if unconscious. Get medical
attention immediately.
Hcc: n1
solubility in water: insoluble
appearance and odor: yellow powder
Stability indicator/materials to avoid: yes
acids. Dla-hmis: strong oxidizing agents, strong alkalis.
stability condition to avoid: none.
hazardous decomposition products: when heated to decomposition emits
toxic lead fumes.
Waste disposal methods: hazardous waste landfill or other epa approved
method. Dla-hmis: dispose of in accordance with local, state and
federal regulations.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: silica, amorphous, precipitated and gel
cas: 112926-00-8
rtecs #: vv8850000
other rec limits: none recommended
osha pel: 20 mppcf; z-3
acgih tlv: 10 mg/m3 tdust; 9394
ingred name: white lead or lead carbonate
cas: 598-63-0
rtecs #: of9275000
other rec limits:
acgih tlv: 0.15 mg (pb)/m3
ingred name: lead chromate
cas: 7758-97-6
rtecs #: gb2975000
fraction by wt: 0.8%
other rec limits: none recommended
osha pel: 0.1 mg(cro3)/m3
acgih tlv: 0.012mg(cr)/m3,a2;94