Secure Ordering: +1 (757) 528-8028
NationalStockNumber.info
NationalStockNumber.INFO

Worldwide distributor of NSN parts and consumables located in the USA.

Circuit Breaker

NSN: 5925-00-295-5462 | Model: M13516/7-7

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating elemen (s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified) ; and controller.

NSN Properties and Flags
NATO Stock Number
5925-00-295-5462
DEMIL
NO
Body Style
Single pole type
Overall Length
3.160 inches
Body Width
1.880 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.060 inches
Unthreaded Mounting Hole Diameter
Between 0.195 inches and 0.225 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.406 inches
Fragility Factor
Moderately rugged
Mounting Surface To Terminal End Distance
2.000 inches
Pole Quantity
1
Mounting Facility Type And Quantity
2 unthreaded hole
Storage Type
General purpose warehouse
Maximum Continuous Load Current Rating Per Pole
80.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
575.0 dc single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Thermal single location
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
Automatic
Internal Trip Release Configuration
Series trip single location
Trip Delay Time In Seconds Per Rated Continuous Current
8.000 at 200 pct single location and 50.000 at 200 pct single location
Inclosure Protection Type For Which Designed
Vibration resistant and shock resistant and salt spray proof and fungus resistant
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location
Test Data Document
81349-mil-c-13516 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Terminal Type And Quantity
2 threaded stud
Specification Data
81349--13561/7bii government specification

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

NSN 5925-00-295-5462 Datasheet

Supply Class (FSC):
Circuit Breakers
Cross Reference:
  • M13516/7-7
  • MIL-C-13516/7
  • 7392439
  • 7392439
  • 3AA7890
  • MS39068-3
  • M13516/BII-80
  • 5925002955462
Cage Codes:
  • Military Specifications (CAGE 81349)
  • U S Army Tank Automotive Command (CAGE 19207)
  • Sensata Technologies, Inc (CAGE 82647)
  • Thales Uk Limited Dba Thales Uk (CAGE U4338)
  • Military Standards (CAGE 96906)
  • E.c.a Etablissement Central (CAGE A00AM)
Schedule B & Trade:
  • Schedule B: 8536200040 (NAICS 335313)

    Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi

  • SITC: 77252

    Automatic circuit breakers for a voltage not exceeding 1, 000 volts

  • End Use: 20005

    Electric apparatus

Identification:
HMIC

P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

PMIC

A - Item does not contain precious metal.

CRITL

- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Freight Information:
  • NMFC:

    061300 - Circuit breaker/switch noi

  • WCC:

    658 - Electrical appliances, small

  • SHC:

    9 - Other or no special handling required (sh)

  • ADC:

    A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.

  • ACC:

    H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)

  • LTL:

    P - 77.5

  • TCC:

    Z - No special type of cargo code applicable

NSN Management Codes:
  • SOS
    S9e
  • AAC
    V
  • Quantity per pack
    1
  • Unit of Measure
    Ea
  • Shelf Life
    N/A
  • Classification Control
    U
  • MGMT_CTL
    9n-----
  • Repariability

Questions & Answers:

What are the historical prices recorded for this stock number?
Historical data shows pricing from $102.30 to $170.51..
Does NSN 5925-00-295-5462 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
Austria, Brazil, Spain, Singapore, Morocco, Canada, Republic Of Korea, Portugal, Greece, and Turkey
What is the NIIN of NSN 5925-00-295-5462?
002955462 or 00-295-5462
Does NSN 5925-00-295-5462 require demilitarization?
Yes - ITAR Controlled
What is the most recent solicitation for NSN 5925-00-295-5462?
No solicitations for this NSN.
When was this national stock number assigned to the federal catalog?
Jan 01, 1963