Home » FSC Catalog » Switches » 5930-00-008-2639

Rotary Switch

SKU: 5930000082639 | Model: 8886700012-1
Description:

2A single mounting facility thread class, 0.344" single mounting facility thread length, 3.663" length, 1.828" height

Specifications from the Manufacturer

Thread Class:
2a single mounting facility
Thread Length:
0.344 inches minimum single mounting facility and 0.391 inches maximum single mounting facility
Overall Length:
3.663 inches maximum
Overall Height:
1.828 inches maximum
Overall Width:
1.609 inches maximum
First Flat Length:
0.428 inches minimum single actuator and 0.448 inches maximum single actuator
Flat Height:
0.211 inches minimum single actuator and 0.221 inches maximum single actuator
Shaft Diameter:
0.247 inches minimum single actuator and 0.251 inches maximum single actuator
Shaft Length:
0.929 inches nominal single actuator
Nonturn Device Radius:
0.531 inches nominal at 3:00 o'clock
Individual Section Quantity:
7
Nonturn Device Type:
Pin at 3:00 o'clock
Operating Temp Range:
-65.0/+85.0 deg celsius
Switch Contact Basic Design:
Nonpile-up symmetrical
Pole Quantity:
1 each section front
Throw Quantity:
24 each section rear
Mounting Method:
Threaded bushing single mounting facility
Nominal Thread Size:
0.375 inches single mounting facility
Contact Voltage Rating In Volts:
115.0 ac at sea level
Contact Voltage Rating In Volts:
28.0 dc at sea level
Shaft Flat/slot Angular Location:
90.0 degrees from nonturn device single actuator
Rotor Through Connection Quantity:
1 each section
Switch Actuator Indexing Position Quantity:
24 single actuator
Shaft Type:
Round, flatted single actuator
Terminal Type:
Tab, solder lug
Contact Switching Action:
Breaks before makes each section rear
Switch Actuator Positioning Increment:
15.0 degrees single actuator
Contact Load Current Rating:
100.0 milliamperes resistive load ac at sea level
Contact Load Current Rating:
200.0 milliamperes resistive load dc at sea level and 20.0 milliamperes inductive load dc at sea level
Style Designator:
Circular wafer, bushing mount
Test Data Document:
81349-mils3786 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.).
Thread Series Designator:
Unef single mounting facility

Pricing and Availability

Request a Quote

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Quantity:
Company:
Name:
Email:
Phone:

Order With Confidence

Certified quality parts supplier
  • MSDS Hazmat Certified
  • certified Committed to quality with 100% product inspection
  • on time delivery icon On-time delivery
Recently Updated in Switches
NSN 5930-00-008-7028 Rotary Switch

2A single mounting facility thread class, 0.375" single mounting facility thread length, 1.419" length, 1.312" height

NSN 5930-00-008-7027 Rotary Switch

2A single mounting facility thread class, 0.031" single mounting facility thread length, 1.204" length, 1.062" height

NSN 5930-00-008-7026 Rotary Switch

2A single mounting facility thread class, 0.375" single mounting facility thread length, 1.424" length, 1.312" height

NSN 5930-00-008-7018 Switch Assembly

Plastic in closure material, 2.407" depth, 4.330" length, 0.320" width, bracket mounting method, moisture resistant environmental protection

NSN 5930-00-008-2639 Datasheet

Supply Class:

5930 SWITCHES

Cross Reference:

  • 8886700012-1
  • 276584M07

Cage Codes:

  • 57057
  • 76854

Replaced or Cancelled:

5930-00-008-2639 is not a replacement of any national stock number and has not been cancelled or replaced itself.

Identification:

NIIN: 000082639
NSN: 5930000082639
DEMIL Code: A
DEMIL Code Meaning: Non-usml/non-ccli - no demil or dod tsc required. department of commerce may impose licensing requirements to certain destinations.
ADPE:
CRITL: X
ENAC:
ESD:
HMIC: P
PMIC: U

Freight Codes:

NMF Desc: Circuit Breaker/switch Noi
NMFC: 061300
UFC: 34410
LTL: 77.5
LCL:
WCC: Communications/electronics, other than sigint/ew or comsec repair parts and components
TCC: No special type of cargo code applicable
SHC: Other or no special handling required (sh)
ADC: Shipment is not a consolidation and does not exceed 84 inches in any dimension.
ACC: Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ASH: No special handling required.

Management Codes:

CTL: 9B----- (MOE: DN)
SOS: SMS
AAC: Insurance/numeric stockage objective item. items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. the item is central
CIIC:
RC:
QUP: 1
UI: EA
SLC: 0

Reference Drawing:

[drawing of 5930-00-008-2639]

Schedule B & Trade:

8536509020 (NAICS 335931)
Switches, rotary, rated at not over 5 a, for a voltage not exceeding 1,000 v
SITC:
77255

Switches for electrical apparatus, n.e.s., for voltages not exceeding 1,000 volts

End Use:
20005

Electric apparatus

Questions & Answers:

What are the historical prices recorded for this stock number?
No pre-dated pricing for this NSN could be found.
What NATO entities are users of this NSN?
No recorded entities for this stock number.
How is national stock number 5930-00-008-2639 defined?
A switch actuated by a definite angular rotation of the switch shaft about its axis. for items having rated actuation travel and pressure characteristics, see switch, sensitive. excludes relay, rotary; switch, stepping; and switch, telephone (as modified).
Does this item require Demilitarization?
Non-usml/non-ccli - no demil or dod tsc required. department of commerce may impose licensing requirements to certain destinations. (note 9).
Is this item ITAR controlled?
No. This item is not ITAR Controlled.
When was this national stock number assigned to the federal catalog?
Jul 16, 1972
last modified: 07/07/2018