Worldwide distributor of NSN parts and consumables located in the USA.
An inclosure, including two or more electrodes, in which a flow of electrons may occur through a vacuum or a contained gas. The electronic conduction takes place either by means of electrons emitted from a cathode or by ionization of the contained gas. Includes phototubes (photoemissive type only), geiger-mueller tubes, traveling wave tubes, cathode ray tubes and microwave tubes (klystron, magnetron, or the like). Excludes items whose primary purpose is to produce light energy. Also excludes photoelectric cell; and semiconductor device (as modified).
Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.
Gas and vapor electron tubes, nesoi
Electronic valves and tubes, n.E.S.
Telecommunications equipment
Y - Indicates information is in the hazardous materials information resource system (hmirs).
PMICU - Precious metal content is unknown
CRITL- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
063473 - Tubes cathode ray, transmitting
491 - Radioactive device
9 - Other or no special handling required (sh)
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
N - Dangerous materiel in limited quantities (no label required)
W - Rating variable
Questions & Answers: |
|
What are the historical prices recorded for this stock number? | |
Historical data shows pricing from $2,466.81 to $4,111.36.. | |
Does NSN 5960-00-188-0948 have a shelf life? | |
No. There is no shelf life applicable for this NSN. | |
What NATO entities are users of this NSN? | |
Department Of The Army, Department Of The Air Force, National Security Agency, Department Of The Navy, U.s. Coast Guard, Spain, Singapore, Belgium, Canada, New Zealand, Germany, Republic Of Korea, Philippines, Portugal, Italy, Denmark, Greece, and Turkey | |
What is the NIIN of NSN 5960-00-188-0948? | |
001880948 or 00-188-0948 | |
Does NSN 5960-00-188-0948 require demilitarization? | |
Yes - ITAR Controlled | |
What is the most recent solicitation for NSN 5960-00-188-0948? | |
No solicitations for this NSN. | |
When was this national stock number assigned to the federal catalog? | |
Jan 01, 1961 |
Effects of overexposure: haz degree depends on type/quant of radiation.
latent effects: somatic/genetic damage.
First aid: use first aid. Call medical emergency care. Remove/isolate
comtaminated clothing.Shower victim(s) w. Soap & h*2o. Detain
personnel/equipment exposed. Advise medical personnel that
victim(s) may be con taminated.
Hcc: a3
Stability indicator/materials to avoid: yes
isolate,segregate from most other type material
hazardous decomposition products: depends on chemical composition;
fission products
Waste disposal methods: controlled disposal required-in accordance with
dod regulations and federal,state & local regulations.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: thorium 232
cas: 7440-29-1
rtecs #: xo6400000
Routes of entry: inhalation: no skin: no ingestion: no
reports of carcinogenicity: ntp: yes iarc: yes osha: no
health hazards acute and chronic: mfr said "not appliciable" in this
field.
explanation of carcinogenicity: contains a small amount of thorium in
the cathode.
effects of overexposure: mfr said "not appliciable" in this field.
medical cond aggravated by exposure: mfr said "not appliciable" in this
field.
First aid: mfr said "not appliciable" in this field.
Hcc: a2
appearance and odor: glass electron tube
Stability indicator/materials to avoid: yes
mfr said "not appliciable" in this field.
stability condition to avoid: mfr said "not appliciable" in this field.
hazardous decomposition products: mfr said "not appliciable" in this
field.
Waste disposal methods: dispose i/a/w all federal, state and local
regulations. manufacturer makes no suggestions as to method of
disposal.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: thorium metal, pyrophoric
cas: 7440-29-1
rtecs #: xo6400000
other rec limits: none specified
Ld50 lc50 mixture: tlv for tungtsen is 5mg/m*3
routes of entry: inhalation: no skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: this tube contains either tungsten or
thoriated tungsten.Thorium is a naturally occuring radioactive
element.No health hazard is associated with natural thorium,however
long term exposure to to dust o r fumes may cause lung problems.
explanation of carcinogenicity: there are no ingredients above 0.1%
which are identified as carcinogens by ntp,iarc or osha.
effects of overexposure: none specified by manufacturer.
medical cond aggravated by exposure: none specified by manufacturer.
First aid: skin: remove contaminated clothing;wash with soap and
water.Get medical attention if needed.Eyes: flush with water for 15
minutes.Get immediate medical attention.Inhal: remove to fresh
air.Give oxygen or artificial respiration if needed.Get immediate
medical attention.Ingest: get prompt qualified medical attention.If
conscious,induce vomiting.
Hcc: n1
appearance and odor: electron tube.
Stability indicator/materials to avoid: yes
strong oxidizing agents(eg. Halogens,nitroc and sulfurinc acid).
stability condition to avoid: none specified by manufacturer.
hazardous decomposition products: tungsten trioxide.
Waste disposal methods: dispose of in accordance with federal,state and
local regulations.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: tungsten,as w,soluble compounds.
cas: 7440-33-7
rtecs #: yo7175000
fraction by wt: 96-100%
other rec limits: none recommended
osha pel: noe established
acgih tlv: 1 mg/m3/3 stel; 9596
ingred name: thorium (natural)
fraction by wt: 0-4%
other rec limits: none recommended