Worldwide distributor of NSN parts and consumables located in the USA.
A grouping of two or more separate electron tubes which have been matched together for a given characteristic such as transconductance. The matched values must be equal or within a specified tolerance. Includes only those tubes designed and specifically tested to provide a desired function. Excludes transistors, semiconductor devices and electron tubes which may be of an identical type but do not meet the above requirements.
Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.
Automatic circuit breaker parts for headings 8535, 8536 or 8537
Parts of electrical apparatus for switching or protecting electrical circuits for making connections to or in electrical circuits, n.E.S.
Electric apparatus
Y - Indicates information is in the hazardous materials information resource system (hmirs).
PMICU - Precious metal content is unknown
CRITL- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
063476 - Tubes noi
491 - Radioactive device
9 - Other or no special handling required (sh)
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
N - Dangerous materiel in limited quantities (no label required)
W - Rating variable
Questions & Answers: |
|
What are the historical prices recorded for this stock number? | |
Historical data shows pricing from $4,481.04 to $7,468.40.. | |
Does NSN 5960-01-067-9506 have a shelf life? | |
No. There is no shelf life applicable for this NSN. | |
What NATO entities are users of this NSN? | |
Department Of The Navy, Poland, Spain, and Turkey | |
What is the NIIN of NSN 5960-01-067-9506? | |
010679506 or 01-067-9506 | |
Does NSN 5960-01-067-9506 require demilitarization? | |
Yes - ITAR Controlled | |
What is the most recent solicitation for NSN 5960-01-067-9506? | |
No solicitations for this NSN. | |
When was this national stock number assigned to the federal catalog? | |
Nov 11, 1978 |
Ld50 lc50 mixture: not specified by manufacturer.
routes of entry: inhalation: yes skin: yes ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: none specified by manufacturer.
explanation of carcinogenicity: product contains no ingredients
currently classified as carcinogenic by ntp, iarc or osha per
manufacturer.
effects of overexposure: product is a sealed tube-no radiation health
hazards expected.
medical cond aggravated by exposure: none specified by manufacturer.
First aid: if contact occurs with internal tube surfaces, wash hands
immediately with soap and water. This will prevent the spread of
contamination.
Hcc: a3
boiling pt: b.P. Text: not given
vapor pres: not given
vapor density: not given
spec gravity: not given
evaporation rate & reference: not given
solubility in water: not given
appearance and odor: glass tube containing less than one microcurie of
colbalt 60
Stability indicator/materials to avoid: yes
none specified by manufacturer.
stability condition to avoid: physical damage
hazardous decomposition products: none specified by manufacturer.
Waste disposal methods: broken or unwanted tubes should be disposed of
as specified in 40 cfr, part 20, sec 20.301. Specific arrangements
may be made with m/a com for disposal of intact tubes that were
manufactured by m/a co m.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: cobalt (sara iii) product contains less than one
microcurie
cas: 7440-48-4
rtecs #: gf8750000
other rec limits: none specified
osha pel: 0.1 mg/m3;as co
acgih tlv: 0.05 mg/m3;dust 9293
Routes of entry: inhalation: no skin: no ingestion: no
health hazards acute and chronic: electron tubes operate at temperatures
that can produce burns to skin if contact is made.
effects of overexposure: burns to skin from touching a heated tube due
to operating temperatures.
medical cond aggravated by exposure: none known.
First aid: use first aid. Call medical emergency care. Remove/isolate
comtaminated clothing. Shower victim(s) with soap & water. Detain
personnel/equipment exposed. Advise medical personnel that
victim(s) may be contaminated.
Hcc: a2
appearance and odor: glass envelope, no odor
Stability indicator/materials to avoid: yes
isolate,segregate from most other type material
Waste disposal methods: controlled disposal required-in accordance with
dod regulations and federal,state & local regulations.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.