NSN: 5960-01-194-4506 | Model: VDU-1091

An inclosure, including two or more electrodes, in which a flow of electrons may occur through a vacuum or a contained gas. The electronic conduction takes place either by means of electrons emitted from a cathode or by ionization of the contained gas. Includes phototubes (photoemissive type only), geiger-mueller tubes, traveling wave tubes, cathode ray tubes and microwave tubes (klystron, magnetron, or the like). Excludes items whose primary purpose is to produce light energy. Also excludes photoelectric cell; and semiconductor device (as modified).

NSN Properties and Flags
NATO Stock Number
5960-01-194-4506
DEMIL
NO
Identifying Number
G00984 specification no.
Recent Solicitations
Solicitation Return by Date Buyer Code Quantity
SPE7M519T4960 2018-11-26 PMCMT 2 EA
SPE7MC15TA195 2015-05-18 PLCLX 1 EA

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

NSN 5960-01-194-4506 Datasheet

Supply Class (FSC):
Electron Tubes And Associated Hardware
Cross Reference:
  • VDU-1091
  • 600984-01
Cage Codes:
  • Communications & Power Industries (CAGE 88236)
  • Edo (CAGE 09017)
Schedule B & Trade:
  • Schedule B: 8540890020 (NAICS 334419)

    Gas and vapor electron tubes, nesoi

  • SITC: 77627

    Electronic valves and tubes, n.E.S.

  • End Use: 21400

    Telecommunications equipment

Identification:
HMIC

Y - Indicates information is in the hazardous materials information resource system (hmirs).

PMIC

A - Item does not contain precious metal.

ADPE

- Represents items with no adp components

CRITL

- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Freight Information:
  • NMFC:

    063476 - Tubes noi

  • WCC:

    72D - Communications/electronics, other than sigint/ew or comsec repair parts and components

  • SHC:

    9 - Other or no special handling required (sh)

  • ADC:

    A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.

  • ACC:

    H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)

  • TCC:

    N - Dangerous materiel in limited quantities (no label required)

  • LTL:

    W - Rating variable

NSN Management Codes:
  • SOS
    Sms
  • AAC
    Z
  • Quantity per pack
    1
  • Unit of Measure
    Ea
  • Shelf Life
    N/A
  • Classification Control
    U
  • MGMT_CTL
    Sf9eh-n
  • Repariability

Questions & Answers:

What are the historical prices recorded for this stock number?
Historical data shows pricing from $19,182.25 to $31,970.41..
Does NSN 5960-01-194-4506 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
Department Of The Air Force
What is the NIIN of NSN 5960-01-194-4506?
011944506 or 01-194-4506
Does NSN 5960-01-194-4506 require demilitarization?
Yes - ITAR Controlled
What is the most recent solicitation for NSN 5960-01-194-4506?
Solicitation SPE7M519T4960 for qty 2 on 11/16/2018
When was this national stock number assigned to the federal catalog?
Nov 14, 1984
MSDS

Material Safety

MSDS BXJYC VDU-1091

Hazards

Routes of entry: inhalation: yes skin: yes ingestion: yes
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: significant exposure to a radionuclide
may cause cancer.

explanation of carcinogenicity: per msds: not listed in ntp, iarc,osha.

effects of overexposure: cancer.

medical cond aggravated by exposure: healing of damaged tissues may be
prolonged.

First Aid

First aid: skin: flush w/water for 15mins. Eye: flush w/water for 15mins.

inhal: remove to fresh air. Ingest: a high oral fluid intake should
be administered following tritium exposure.

Chemical Properties

Hcc: a1
nrc/state lic num: 20-02237-04
boiling pt: b.P. Text: -414f,-248c
melt/freeze pt: m.P/f.P text: -425f,-254c
vapor pres: 18.317 atm
spec gravity: 6.0
solubility in water: 100
appearance and odor: article. Gas, no odor.

Reactivity

Stability indicator/materials to avoid: yes
oxidizers.

stability condition to avoid: temperatures in excess of 400c will caue
decomposition of tit2 w/release of tritium gas.

hazardous decomposition products: unbound tritium.

Proper Disposal

Waste disposal methods: form: normal-solid,
radioactivity: 12.5millicuries, radioactive matl: tritium(h3 or t) as
tit2.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: tritium as solid titanium tritide
fraction by wt:
other rec limits: none recommended