Secure Ordering: +1 (757) 528-8028
NationalStockNumber.info
NationalStockNumber.INFO

Worldwide distributor of NSN parts and consumables located in the USA.

Electron Tube

NSN: 5960-01-214-0434 | Model: VDS-1082

An inclosure, including two or more electrodes, in which a flow of electrons may occur through a vacuum or a contained gas. The electronic conduction takes place either by means of electrons emitted from a cathode or by ionization of the contained gas. Includes phototubes (photoemissive type only), geiger-mueller tubes, traveling wave tubes, cathode ray tubes and microwave tubes (klystron, magnetron, or the like). Excludes items whose primary purpose is to produce light energy. Also excludes photoelectric cell; and semiconductor device (as modified).

NSN Properties and Flags
NATO Stock Number
5960-01-214-0434
DEMIL
NO

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

NSN 5960-01-214-0434 Datasheet

Supply Class (FSC):
Electron Tubes And Associated Hardware
Cross Reference:
  • VDS-1082
  • 170299-1
Cage Codes:
  • Communications & Power Industries (CAGE 88236)
  • Harris Corporation (CAGE 24930)
Schedule B & Trade:
  • Schedule B: 8540890020 (NAICS 334419)

    Gas and vapor electron tubes, nesoi

  • SITC: 77627

    Electronic valves and tubes, n.E.S.

  • End Use: 21400

    Telecommunications equipment

Identification:
HMIC

Y - Indicates information is in the hazardous materials information resource system (hmirs).

PMIC

A - Item does not contain precious metal.

ADPE

- Represents items with no adp components

CRITL

- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Freight Information:
  • NMFC:

    063476 - Tubes noi

  • WCC:

    724 - Radio tubes, packed separately

  • SHC:

    9 - Other or no special handling required (sh)

  • ADC:

    A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.

  • TCC:

    A - Radioactive substances, un class 7 (radioactive label)

  • ACC:

    H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)

  • LTL:

    W - Rating variable

NSN Management Codes:
  • SOS
    Nrp
  • AAC
    Z
  • Quantity per pack
    No qup
  • Unit of Measure
    Ea
  • Shelf Life
    N/A
  • Classification Control
    U
  • MGMT_CTL
    7e--00r
  • Repariability
    If condemned or uneconomically repairable, then dispose at intermediate level.

Questions & Answers:

What are the historical prices recorded for this stock number?
Historical data shows pricing from $19,334.25 to $32,223.75..
Does NSN 5960-01-214-0434 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
Department Of The Navy, and Spain
What is the NIIN of NSN 5960-01-214-0434?
012140434 or 01-214-0434
Does NSN 5960-01-214-0434 require demilitarization?
Yes - ITAR Controlled
What is the most recent solicitation for NSN 5960-01-214-0434?
No solicitations for this NSN.
When was this national stock number assigned to the federal catalog?
Aug 05, 1985
MSDS

Material Safety

MSDS CDXCJ VDS1082

Hazards

Ld50 lc50 mixture: none specified by manufacturer.

routes of entry: inhalation: yes skin: yes ingestion: yes
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: acute: significant expos to
radionuclide may cause cancer. Signs & symps of expos: tritium is
beta emitter. If expos is suspected, seek med attn, urine assay for
tritium is only means of measuring degre e of expos. Norm operating
voltages canbe deadly. Rf radia may cause serious bodily injury,
blndness (efts of overexp)
explanation of carcinogenicity: not relevant.

effects of overexposure: hlth haz: or death, may affect card pacemakers.

x-ray radia can prdce dangerous, possibly fatal, x-rays. May emit
ionizing radia. Ultraviolent radia may cause painful skin burns &
serious eye dmg/irrit . Beryllium & beryllium oxide are highly tox.

may create tox/corr cmpds. Implosion haz may injure from flying
(supdat)
medical cond aggravated by exposure: healing of damaged tissues may be
prolonged.

First Aid

First aid: skin cont: flush with water for 15 minutes. Eye cont: flush
with water for at least 15 minutes. Inhalation: remove to fresh air.

ingestion: a high oral fluid intake should be administered following
tritiu m exposure.

Chemical Properties

Hcc: a3
boiling pt: b.P. Text: -414f,-248c
melt/freeze pt: m.P/f.P text: -425f,-254c
vapor pres: 18.317
spec gravity: 6.0
solubility in water: 100%
appearance and odor: gas, no odor.

Reactivity

Stability indicator/materials to avoid: yes
oxidizers.

stability condition to avoid: temps in excess of 400c will cause decomp
of tit*2 w/release of tritium gas.

hazardous decomposition products: dielectric gas: if breakdown does
occur, gas may decompose & form highly tox & corr cmdps. For
example, freon gas(supdat)

Proper Disposal

Waste disposal methods: disp must be i/a/w fed, state & loc regs . Avoid
inhal gases from broken tubes containing tritium. Dispose of
broken/spent tubes as specified in 10 cfr, part 20 & 10 cfr, part
30. Disp of tubes containing beryllium must be done in safe(ing
12)
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: tritium
fraction by wt: 1%
osha pel: n/k
acgih tlv: n/k

ingred name: supdat: liq can reach scalding temps & cause serious burns.

operate @ lethal voltages. May cause sev injury. Never(ing 3)
rtecs #: 9999999zz

ingred name: ing 2: look into or expose any part of the body to an
antenna or open waveguide. Capable of producing x-ray (ing 4)
rtecs #: 9999999zz

ingred name: ing 3: radiation. Provide adequate x-ray shielding. Check
x-ray levels. Gas discharge tubes can produce ultra- (ing 5)
rtecs #: 9999999zz

ingred name: ing 4: violet radiation. Painful skin burns can result. Eye
injury could be permanent. Maintain shielding intact. (ing 6)
rtecs #: 9999999zz

ingred name: ing 5: avoid exposure to an ultraviolet source. A glass tube
may implode. Flying debris may result in injury. (ing 7)
rtecs #: 9999999zz

ingred name: ing 6: avoid inhaling gas or dust from broken tubes. A
rupture of the cooling channel or contact with hot portions(ing 8)
rtecs #: 9999999zz

ingred name: ing 7: of the tube could scald or burn. Liquid cooling may
leave surfaces hot. These areas can become very hot (ing 9)
rtecs #: 9999999zz

ingred name: ing 8: even though other parts of the tube are cool. Hot
surfaces may reamin hot after the end of tube operation.(ing 10)
rtecs #: 9999999zz

ingred name: ing 9: avoid touching these surfaces during & after tube
operation. Maintain air flow until hot surfaces have (ing 11)
rtecs #: 9999999zz

ingred name: ing 10: cooled. For more specific health hazard information
contact nehc .

rtecs #: 9999999zz

ingred name: waste disp meth: manner & i/a/w federal, state & local laws
& regulations. Safeguard people in disp operation. (ing 13)
rtecs #: 9999999zz

ingred name: ing 12: warn people in any possible salvage operation.

rtecs #: 9999999zz

ingred name: other prec: matched rf load. Monitor tube and system for rf
radiation leakage at regular intervals and after (ing 15)
rtecs #: 9999999zz

ingred name: ing 14: servicing. Never operate high voltage tubes without
adequate x-ray shielding in place. Monitor the tube (ing 16)
rtecs #: 9999999zz

ingred name: ing 15: and system for x-ray radiation at regular intervals
and after servicing. For more specific precautions (ing 17)
rtecs #: 9999999zz

ingred name: ing 16: contact nehc .

rtecs #: 9999999zz