Worldwide distributor of NSN parts and consumables located in the USA.
A battery, composed of two or more cells forming a single unit, which may or may not be readily separable and which may be efficiently recharged by sending an electric current through the cells in a direction opposite that of the discharging current. the item may be furnished with integral charging facilities. for items which are composed of a single cell see cell, battery.
Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.
Storage batteries, nesoi
Electric accumulators (storage batteries)
Electric apparatus
Y - Indicates information is in the hazardous materials information resource system (hmirs).
PMICA - Item does not contain precious metal.
CRITL- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
060680 - Batteries or cell
582 - Batteries and parts (see 131), (vehicle parts)
9 - Other or no special handling required (sh)
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
W - Rating variable
Z - No special type of cargo code applicable
Questions & Answers: |
|
What are the historical prices recorded for this stock number? | |
Historical data shows pricing from $2,085.26 to $3,475.44.. | |
Does NSN 6140-00-449-5261 have a shelf life? | |
No. There is no shelf life applicable for this NSN. | |
What NATO entities are users of this NSN? | |
Department Of The Air Force, Department Of The Navy, Spain, and Singapore | |
What is the NIIN of NSN 6140-00-449-5261? | |
004495261 or 00-449-5261 | |
Does NSN 6140-00-449-5261 require demilitarization? | |
Yes - ITAR Controlled | |
What is the most recent solicitation for NSN 6140-00-449-5261? | |
No solicitations for this NSN. | |
When was this national stock number assigned to the federal catalog? | |
Dec 08, 1969 |
Routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: yes iarc: yes osha: no
health hazards acute and chronic: acute: potassium hydroxide-skin burns.
nickel, nickel hydroxide, cadmium, cadmium hydroxide-possible
contact dermatitis. Chronic: nickel, nickel hydroxide-suspected
carcinogens. Cadmium, cadmium hydro xide-renal failure, respiratory
problems.
explanation of carcinogenicity: cadmium, nickel are both listed by iarc
and ntp as animal positive carcinogens.
effects of overexposure: possible skin burns.
First aid: wash thoroughly with large volumes of water. Inhale: remove
to fresh air, see physician. Eyes: wash with large volumes of
water, see physician. Skin: wash with large volumes of water.
ingest: contact a physician immediately.
Hcc: b1
Not applicable.
stability condition to avoid: not applicable.
hazardous decomposition products: sublimes as cadmium oxide at 2800f.
Waste disposal methods: send to a certified hazardous waste disposal
site.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: cadmium, cadmium hydroxide
cas: 7440-43-9
rtecs #: eu9800000
fraction by wt: 14.63%
other rec limits: none recommended
osha pel: see 1910.1027
acgih tlv: 0.01 mg/m3 dust;9394
epa rpt qty: 10 lbs
dot rpt qty: 10 lbs
ingred name: nickel, nickel hydroxide
cas: 7440-02-0
rtecs #: qr5950000
fraction by wt: 26.07%
other rec limits: none recommended
osha pel: 1 mg/m3
acgih tlv: 1 mg/m3; 9293
ingred name: potassium hydroxide (sara iii)
cas: 1310-58-3
rtecs #: tt2100000
fraction by wt: 6.5%
other rec limits: none recommended
osha pel: c, 2 mg/m3
acgih tlv: c 2 mg/m3; 9293
epa rpt qty: 1000 lbs
dot rpt qty: 1000 lbs
Ld50 lc50 mixture: not provided
routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: yes iarc: yes osha: yes
health hazards acute and chronic: not provided
explanation of carcinogenicity: nickel and cadmium and their compounds
are listed as carcinogens or potential carcinogens by ntp, iarc and
osha, per msds.
effects of overexposure: irritation of the nose and throat, sweating,
chills, shortness of breath, weakness, local dermititis, nausea,
coughing, chest pains.
medical cond aggravated by exposure: respiratory system disorders,
prostate disorders, liver and kidney disorders.
First aid: inhaltion: remove from exposure, see physician. Skin or eyes:
flush with water for 15 minutes. See physician if symptoms develop.
Hcc: z5
nrc/state lic num: not relevant
melt/freeze pt: m.P/f.P text: not available
decomp temp: decomp text: not provided
spec gravity: 1.6
ph: not provided
solubility in water: not provided
appearance and odor: not provided
corrosion rate: not provided
Stability indicator/materials to avoid: yes
stability condition to avoid: general storage procedures for hazardous
materials are acceptable.
hazardous decomposition products: metal oxide fumes may be evolved at
temperatures above melting point.
Waste disposal methods: dispose of in accordance with federal, state and
local laws. If discarded, treat as hazardous waste.
Ingred name: cadmium (present as cadmium, cadmium hydroxide, cadmium
oxide)
minumum % wt: 0.
maxumum % wt: 20.
other rec limits: not provided
osha pel: 0.2 mg/m3 dust
acgih tlv: 0.01 mg/m3 dust
ingred name: nickel (present as nickel, nickel hydroxide, nickel oxide)
minumum % wt: 15.
maxumum % wt: 35.
other rec limits: not provided
osha pel: 1 mg/m3 as ni
acgih tlv: 1 mg/m3 as ni
ld50 lc50 mixture: none specified by manufacturer.
carcinogenicity inds - ntp: yes
iarc: yes
osha: yes
explanation of carcinogenicity: nickel and cadmium and their compounds are
listed as carcinogens or potential carcinogens by ntp, iarc, osha.
signs and symptions of overexposure: irritation of nose and throat, sweating,
shortness of breath, weakness, local dermatitiss, nausea, coughing, chest
pains.
medical cond aggravated by exposure: respiratory system disorders, prostatic
disorders, liver and kidney disorders.
first aid: inhalation: remove from exposure, see physician. Ingestion: induce
vomiting if conscious, see physician. Skin/ eyes: flush with water for 15
minutes. See physician if symptoms develop.
hcc: z5
spec gravity: 1.6
evaporation rate & reference: n/a (buac=1)
solubility in water: field left blank
appearance and odor: field left blank by manufacturer.
product id: nickel-cadmium sealed cell battery
cage: 58414
company name: avex electronics corp
street: 1683 winchester road
po box: 1026
city: bensalem pa
zipcode: 19020-4510
health emergency phone: 215-638-1515
label required ind: y
date of label review: 05/09/2001
status code: a
origination code: f
chronic hazard ind: y
eye protection ind: yes
skin protection ind: yes
signal word: warning
respiratory protection ind: yes
health hazard: moderate
contact hazard: moderate
fire hazard: none
=======================================================
responsible party cage: 58414
trans id no: 156920
product id: nickel-cadmium sealed cell battery
msds prepared date: 02/19/1999
review date: 05/09/2001
mfn: 1
multiple kit number: 0
unit of issue: ea
container qty: 1
type of container: battery
Hazard and precautions: target organs: n/p. not applicable for finished
product used under normal conditions.
spill release procedures: contain spill. Collect the spilled material and place
it in a plastic-lined container hepa vaccuming is preferred. Flush spill area
with water.
neutralizing agent: none specified by manufacturer.
waste disposal methods: dispose of in accordance with all federal, state and
local regulations. If discarded, treat as hazardous waste.
handling and storage precautions: wear niosh/msha approved dust masks or
respirators; impervious gloves; and safety glasses or goggles.
other precautions: keep container closed, avoid contact with clothing, avoid
generating dust.