Secure Ordering: +1 (757) 528-8028
NationalStockNumber.info
NationalStockNumber.INFO

Worldwide distributor of NSN parts and consumables located in the USA.

Storage Battery

NSN: 6140-01-117-6545 | Model: GC6200TYPEA

A battery, composed of two or more cells forming a single unit, which may or may not be readily separable and which may be efficiently recharged by sending an electric current through the cells in a direction opposite that of the discharging current. the item may be furnished with integral charging facilities. for items which are composed of a single cell see cell, battery.

NSN Properties and Flags
NATO Stock Number
6140-01-117-6545
DEMIL
NO
Terminal Quantity
2
Terminal Type
Wing nut
Overall Length
7.000 inches
Overall Height
5.250 inches
Overall Width
3.420 inches
Case Material
Plastic
Battery Electrolyte
Silica-gel
Fording Feature
Not included
Terminal Location
Top
Ampere Hour Capacity
20.00
Time Capacity In Hours
20.00
Cell Quantity
3
Plate Material
Lead
Nonspilling Feature
Included
Charge Indicator
Not included
Electrolyte Level Indicator
Not included
Storage/shipment Condition
Dry charged
Integral Charging Facility
Not included
Plate Type
Negative and positive
Case Design Type
Sealed
Voltage In Volts
6.0

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

NSN 6140-01-117-6545 Datasheet

Supply Class (FSC):
Rechargeable Batteries
Cross Reference:
  • GC6200TYPEA
  • GC6200TYPEA
Cage Codes:
  • Johnson Controls, Inc. (CAGE 25244)
  • Mepco/centralab (CAGE 16546)
Schedule B & Trade:
  • Schedule B: 8507800002 (NAICS 335911)

    Storage batteries, nesoi

  • SITC: 77812

    Electric accumulators (storage batteries)

  • End Use: 20005

    Electric apparatus

Identification:
HMIC

Y - Indicates information is in the hazardous materials information resource system (hmirs).

PMIC

A - Item does not contain precious metal.

CRITL

- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Freight Information:
  • NMFC:

    060680 - Batteries or cell

  • WCC:

    582 - Batteries and parts (see 131), (vehicle parts)

  • SHC:

    9 - Other or no special handling required (sh)

  • ADC:

    A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.

  • ACC:

    H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)

  • LTL:

    W - Rating variable

  • TCC:

    Z - No special type of cargo code applicable

NSN Management Codes:
  • SOS
    Sms
  • AAC
    L
  • Quantity per pack
    1
  • Unit of Measure
    Ea
  • Shelf Life
    6 mo.
  • Classification Control
    U
  • MGMT_CTL
    Lp9sx-n
  • Repariability

Questions & Answers:

What are the historical prices recorded for this stock number?
Historical data shows pricing from $178.81 to $298.01..
Does NSN 6140-01-117-6545 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
Department Of The Air Force, and Department Of The Navy
What is the NIIN of NSN 6140-01-117-6545?
011176545 or 01-117-6545
Does NSN 6140-01-117-6545 require demilitarization?
Yes - ITAR Controlled
What is the most recent solicitation for NSN 6140-01-117-6545?
No solicitations for this NSN.
When was this national stock number assigned to the federal catalog?
Aug 19, 1981
MSDS

Material Safety

MSDS BNWCF GELL CELL/DYNASTY/GELLED OR ABSORBED ELECTR

Hazards

Ld50 lc50 mixture: ld50 (oral rat) is 2140 mg/kg (h2so4)
routes of entry: inhalation: yes skin: yes ingestion: yes
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: acute: may cause irritation of
respiratory tract, eyes, skin or gi tract. May cause burns of skin,
eyes, or gi tract. May cause corneal damage or blindness. Chronic:
tooth erosion, inflammation of nos e, throat and bronchial tubes.

explanation of carcinogenicity: the electrolyte and lead are not listed
by iarc, ntp, or osha as a carcinogen.

effects of overexposure: inhalation: burning sensation in nose, throat
and lungs, coughing, wheezing, shortness of breath. Eyes: redness,
tearing, blurred vision, burns, severe pain. Skin: severe pain,
burns, redness, rash, i tching. Ingestion: burns of mouth, throat,
and esophagus, severe stomach pain, nausea, vomiting.

medical cond aggravated by exposure: persons with a history of ailments
or with a pre-existing disease involving the respiratory tract or
teeth may be at increased risk from exposure.

First Aid

First aid: inhalation: remove to fresh air. Resuscitate if not breathing.

get medical attention. Eyes: immediately flush with plenty of water
for 15 minutes holding eyelids open. Get prompt medical attention.

skin : remove contaminated clothing. Wash withplenty of water for 15
minutes. Get medical advice. ingestion: do not induce vomiting.

give nothing by mouth if unconscious. Get immediate medical
attention.

Chemical Properties

Hcc: z7
appearance and odor: an object consisting of a transparent to opaque
case and sealed cover. Odorless

Reactivity

Stability indicator/materials to avoid: yes
contact of electrolyte with organic material and combustibles, strong
alkalis, reducing agents, strong oxidizing agents
stability condition to avoid: overcharging, sources of ignition
hazardous decomposition products: sulfuric acid mist, sulfur dioxide and
carbon monoxide may be released when electrolyte decomposes.

Proper Disposal

Waste disposal methods: both electrolyte and scrap batteries are
regulated hazardous waste. Scrap batteries contain materials which
are recyclable and must be returned to authorized recycler.

electrolyte should be hauled to a permitted treatment facility.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: lead (sara iii)
cas: 7439-92-1
rtecs #: of7525000
other rec limits: none recommended
osha pel: 0.05 mg/m3;1910.1025
acgih tlv: 0.15 mg/m3;dust 9192
epa rpt qty: 1 lb
dot rpt qty: 1 lb

ingred name: lead peroxide
cas: 1309-60-0
rtecs #: og0700000
other rec limits: none recommended

ingred name: lead sulfate (sara iii)
cas: 7446-14-2
rtecs #: og4375000
other rec limits: none recommended
osha pel: see 1910.1025
acgih tlv: 0.15 mg pb/m3; 9192
epa rpt qty: 100 lbs
dot rpt qty: 100 lbs

ingred name: sulfuric acid (sara iii) (as absorbed/gelled electrolyte)
cas: 7664-93-9
rtecs #: ws5600000
other rec limits: none recommended
osha pel: 1 mg/m3
acgih tlv: 1 mg/m3; 9192
epa rpt qty: 1000 lbs
dot rpt qty: 1000 lbs