Worldwide distributor of NSN parts and consumables located in the USA.
A battery, composed of two or more cells forming a single unit, which may or may not be readily separable and which may be efficiently recharged by sending an electric current through the cells in a direction opposite that of the discharging current. the item may be furnished with integral charging facilities. for items which are composed of a single cell see cell, battery.
Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.
Storage batteries, nesoi
Electric accumulators (storage batteries)
Electric apparatus
Y - Indicates information is in the hazardous materials information resource system (hmirs).
PMICA - Item does not contain precious metal.
CRITL- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
060680 - Batteries or cell
582 - Batteries and parts (see 131), (vehicle parts)
9 - Other or no special handling required (sh)
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
W - Rating variable
Z - No special type of cargo code applicable
Questions & Answers: |
|
What are the historical prices recorded for this stock number? | |
Historical data shows pricing from $1,182.11 to $1,970.19.. | |
Does NSN 6140-01-174-7248 have a shelf life? | |
No. There is no shelf life applicable for this NSN. | |
What NATO entities are users of this NSN? | |
Department Of The Air Force, and Department Of The Navy | |
What is the NIIN of NSN 6140-01-174-7248? | |
011747248 or 01-174-7248 | |
Does NSN 6140-01-174-7248 require demilitarization? | |
Yes - ITAR Controlled | |
What is the most recent solicitation for NSN 6140-01-174-7248? | |
No solicitations for this NSN. | |
When was this national stock number assigned to the federal catalog? | |
Mar 21, 1984 |
Ld50 lc50 mixture: ld50 (oral rat) is 2140 mg/kg
routes of entry: inhalation: yes skin: yes ingestion: yes
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: acute exposure to electrolyte may
cause burns to tissue. Can cause severe or permanent injury.
ingestion causes severe injury. Chronic inhalation of acid mists
can cause upper respiratory irritation a nd possible pulmonary
edema.
explanation of carcinogenicity: this chemical is not listed by iarc,
ntp, or osha as a carcinogen.
effects of overexposure: severe irritation or burns to eyes, nose and
throat. Pulmonary edema, bronical emphysema, conjunctivitis,
stomatitis, dental erosion, nausea and vomiting.
medical cond aggravated by exposure: persons with a history of ailments
or with a pre-existing disease involving the respiratory tract may
be at increased risk from exposure.
First aid: inhalation: remove to fresh air. Resuscitate if not breathing.
get medical attention. Eyes: immediately flush with plenty of water
for 15 minutes holding eyelids open. Get prompt medical attention.
skin : remove contaminated clothing. Wash with plenty of water for
15 minutes. Get medical advice. ingestion: do not induce vomiting.
give nothing by mouth if unconscious. Get immediate medical
attention.
Hcc: c1
spec gravity: 1.215-1.250
ph: 1
solubility in water: complete (h2so4)
appearance and odor: sulfuric acid electrolyte is a colorless to straw
colored oily odorless liquid.
Stability indicator/materials to avoid: yes
strong alkalis
hazardous decomposition products: oxides of sulfur
Waste disposal methods: disposal should be made in accordance with all
applicable federal, state and local environmental regulations.
small spills that have been neutralized can be flushed to sanitary
sewer.
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ingred name: sulfuric acid (sara iii)
cas: 7664-93-9
rtecs #: ws5600000
fraction by wt: 10-30%
other rec limits: none specified
osha pel: 1 mg/m3
acgih tlv: 1 mg/m3; 9192
epa rpt qty: 1000 lbs
dot rpt qty: 1000 lbs
ingred name: lead (sara iii)
cas: 7439-92-1
rtecs #: of7525000
fraction by wt: 60%
other rec limits: none specified
osha pel: 0.05 mg/m3;1910.1025
acgih tlv: 0.15 mg/m3;dust 9192
epa rpt qty: 1 lb
dot rpt qty: 1 lb
ingred name: antimony (sara iii)
cas: 7440-36-0
rtecs #: cc4025000
fraction by wt: 1-5%
other rec limits: none specified
osha pel: 0.5 mg/m3
acgih tlv: 0.5 mg sb/m3; 9192
epa rpt qty: 5000 lbs
dot rpt qty: 5000 lbs
ingred name: arsenic (sara iii)
cas: 7440-38-2
rtecs #: cg0525000
fraction by wt:
other rec limits: none specified
osha pel: 0.5 mg/m3 (as)
acgih tlv: 0.01,a1 mg/m3; 9394
epa rpt qty: 1 lb
dot rpt qty: 1 lb