Storage Battery

NSN: 6140-01-210-1964 | Model: MS52149-1

A battery, composed of two or more cells forming a single unit, which may or may not be readily separable and which may be efficiently recharged by sending an electric current through the cells in a direction opposite that of the discharging current. the item may be furnished with integral charging facilities. for items which are composed of a single cell see cell, battery.

NSN Properties and Flags
NATO Stock Number
6140-01-210-1964
DEMIL
NO
Terminal Quantity
2
Terminal Type
Taper post
Overall Length
11.250 inches
Overall Height
Between 8.810 inches and 9.070 inches
Overall Width
Between 10.440 inches and 10.560 inches
Battery Electrolyte
Lead acid
Portability Method
Handle, each end, folding
Terminal Location
Top
Cell Quantity
6
Plate Material
Lead
Nonspilling Feature
Included
Storage/shipment Condition
Dry charged
Case Design Type
Filling plug openings
Voltage In Volts
12.0

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

NSN 6140-01-210-1964 Datasheet

Supply Class (FSC):
Rechargeable Batteries
Cross Reference:
  • MS52149-1
  • MS52149-1
Cage Codes:
  • Military Standards (CAGE 96906)
  • Goriziane Group Spa (CAGE A9271)
Replacements:
  • 6140-01-210-1964 replaces 6140-01-305-1092
Schedule B & Trade:
  • Schedule B: 8507800002 (NAICS 335911)

    Storage batteries, nesoi

  • SITC: 77812

    Electric accumulators (storage batteries)

  • End Use: 20005

    Electric apparatus

Identification:
HMIC

Y - Indicates information is in the hazardous materials information resource system (hmirs).

PMIC

A - Item does not contain precious metal.

CRITL

- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Freight Information:
  • NMFC:

    060700 - Batteries or cells

  • WCC:

    582 - Batteries and parts (see 131), (vehicle parts)

  • SHC:

    9 - Other or no special handling required (sh)

  • ADC:

    A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.

  • ACC:

    H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)

  • LCL:

    J - 100.0

  • LTL:

    S - 60.0

  • TCC:

    Z - No special type of cargo code applicable

NSN Management Codes:
  • SOS
    S9g
  • AAC
    Y
  • Quantity per pack
    1
  • Unit of Measure
    Ea
  • Shelf Life
    N/A
  • Classification Control
    U
  • MGMT_CTL
    9g----c
  • Repariability

Questions & Answers:

What are the historical prices recorded for this stock number?
Historical data shows pricing from $327.08 to $545.13..
Does NSN 6140-01-210-1964 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
National Aeronautics and Space Administration, National Aeronautics and Space Administration, Austria, Lithuania, Poland, Brazil, Spain, Singapore, Morocco, Belgium, Canada, New Zealand, Republic Of Korea, United Kingdom, Philippines, Italy, Denmark, Greece, Turkey, and Nato Maintenance and Supply Agency
What is the NIIN of NSN 6140-01-210-1964?
012101964 or 01-210-1964
Does NSN 6140-01-210-1964 require demilitarization?
Yes - ITAR Controlled
What is the most recent solicitation for NSN 6140-01-210-1964?
No solicitations for this NSN.
When was this national stock number assigned to the federal catalog?
Jun 07, 1985
MSDS

Material Safety

MSDS BNWDL LEAD ACID BATTERY

Hazards

Ld50 lc50 mixture: unknown *
routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: yes iarc: yes osha: yes
health hazards acute and chronic: acute: burns, severe irritation of
skin, eyes, mouth, throat, esophagus and stomach; inflammation of
bronchial membranes. Chronic: erosion of teeth, inflammation of
nose, throat and bronchial tubes. *
explanation of carcinogenicity: lead is listed by iarc and ntp. Arsenic
is listed by iarc, ntp and osha. *
effects of overexposure: cough, increased respiratory rate, stinging,
burning sensation on skin, eye irritation, discoloration of teeth.

*
medical cond aggravated by exposure: exposure to mists may cause lung
damage and aggravate pulmonary conditions. Contact with skin may
aggravate skin diseases such as eczema and contact dermatitis. *

First Aid

First aid: eyes/skin: flush with plenty of water. See doctor
immediately. Remove contaminated clothing and shoes. Inhalation:
remove to fresh air. Give oxygen/cpr if needed. See doctor.

ingestion: do not induce vomiting. Give milk or water, followed by
2 ounces of milk of magnesia (no carbonates). See doctor
immediately. *

Chemical Properties

Hcc: c1
nrc/state lic num: n/r *
boiling pt: b.P. Text: 203f,95c *
melt/freeze pt: m.P/f.P text: n/r *
decomp temp: decomp text: unknown *
vapor pres: 10 *
vapor density: >1 *
spec gravity: 1.23-1.35 *
ph: acidic
evaporation rate & reference:
solubility in water: complete *
appearance and odor: acid in battery is clear liquid with sharp,
penetrating, pungent odor. *
percent volatiles by volume: n/r *

Reactivity

Stability indicator/materials to avoid: yes
combustibles, organic material, strong reducing agents, metals, sulfur
trioxide gas, strong oxidizers, water. *
stability condition to avoid: avoid shorting, use only approved charging
methods. Avoid overcharging and sources of ignition. *
hazardous decomposition products: sulfuric acid fumes, sulfur dioxide,
sulfur trioxide, carbon monoxide, hydrogen gas. *

Proper Disposal

Waste disposal methods: consult your local environmental officer.

dispose of in accordance with federal, state and local
environmental regualtions. Spend batteries: send to secondary lead
smelter for recycling. *
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: sulfuric acid (sara iii) *
cas: 7664-93-9
rtecs #: ws5600000
fraction by wt: 10-30% *
other rec limits: none specified *
osha pel: 1 mg/m3 *
acgih tlv: 1 mg/m3; 9192 *
epa rpt qty: 1000 lbs
dot rpt qty: 1000 lbs

ingred name: antimony (sara iii)
cas: 7440-36-0
rtecs #: cc4025000
fraction by wt: 2%
other rec limits: none specified
osha pel: 0.5 mg/m3
acgih tlv: 0.5 mg sb/m3; 9192
epa rpt qty: 5000 lbs
dot rpt qty: 5000 lbs

ingred name: arsenic (sara iii)
cas: 7440-38-2
rtecs #: cg0525000
fraction by wt: 0.2%
other rec limits: none specified
osha pel: 0.5 mg/m3 (as)
acgih tlv: 0.01,a1 mg/m3; 9394
epa rpt qty: 1 lb
dot rpt qty: 1 lb

ingred name: calcium, metal
cas: 7440-70-2
rtecs #: ev8040000
fraction by wt: 0.2%
other rec limits: none specified

ingred name: tin
cas: 7440-31-5
rtecs #: xp7320000
fraction by wt: 0.2%
other rec limits: none specified
osha pel: 2 mg/m3
acgih tlv: 2 mg/m3; 9192

ingred name: polypropylene
cas: 9003-07-4
rtecs #: ud1842000
fraction by wt:
other rec limits: none specified

ingred name: polystyrene
cas: 9003-53-6
rtecs #: wl6475000
fraction by wt:
other rec limits: none specified

ingred name: styrene acrylonitrile
cas: 9003-54-7
fraction by wt:
other rec limits: none specified

ingred name: acrylonitrile butadiene styrene
cas: 9003-56-9
fraction by wt:
other rec limits: none specified

ingred name: styrene butadiene
cas: 9003-55-8
fraction by wt:
other rec limits: none specified

ingred name: polyvinylchloride
cas: 9002-86-2
fraction by wt:
other rec limits: none specified

ingred name: polycarbonate
fraction by wt:
other rec limits: none specified

ingred name: hard rubber
fraction by wt:
other rec limits: none specified

MSDS BSQDR BATTERY WET, FILLED WITH ACID

Hazards

Routes of entry: inhalation: yes skin: no ingestion: yes
reports of carcinogenicity: ntp: yes iarc: yes osha: no
health hazards acute and chronic: contact may cause eye, nose, throat
irritation; possible severe skin burns, erosion of teeth.

inhalation: respiratory difficulty; inflammation of nose, throat, &
bronchial tubes.

explanation of carcinogenicity: see ingredients
medical cond aggravated by exposure: pulmonary edema, bronchitis,
emphysema, dental erosion, tracheobronchitis.

First Aid

First aid: skin: flush with large amounts of water for at least 15
minutes. Remove contaminated clothing. Ingestion: give large
amounts of water, do not induce vomiting. Obtain medical attention
in all cases.

Chemical Properties

Hcc: c1
boiling pt: b.P. Text: 235 f
decomp temp: decomp text: 322-770f
vapor pres: 13
spec gravity: 1.220-1.325
evaporation rate & reference: (bu ac=1):
solubility in water: complete
appearance and odor: clear, odorless, colorless

Reactivity

Stability indicator/materials to avoid: yes
strong oxidizing agents (such as hot nitric acid)
stability condition to avoid: temperatures > 322-770f & other ignition
sources
hazardous decomposition products: hydrogen gas, co, co2, & acid
mist/vapors

Proper Disposal

Waste disposal methods: lead-acid batteries are completely recyclable.

to return batteries to east penn, call (215) 682-6361. Un2794.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: lead, inorganic lead (suspected human carcinogen by iarc,
ntp & acgih)
cas: 7439-92-1
rtecs #: of7525000
fraction by wt: 43-70%
acgih tlv: 0.15 mg/cum
epa rpt qty: 1 lb
dot rpt qty: 1 lb

ingred name: antimony
cas: 7440-36-0
rtecs #: cc4025000
fraction by wt: 0-4%
osha pel: 0.5 mg/cum
acgih tlv: 0.5 mg/cum
epa rpt qty: 5000 lbs
dot rpt qty: 5000 lbs

ingred name: sulfuric acid ic=intended changes
cas: 7664-93-9
rtecs #: ws5600000
fraction by wt: 20-44%
osha pel: 1 mg/cum
acgih tlv: 1 mg/cum=ic
epa rpt qty: 1000 lbs
dot rpt qty: 1000 lbs

MSDS BSSKW LEAD ACID STORAGE BATTERY

Hazards

Ld50 lc50 mixture: none specified by manufacturer.

routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: unknown iarc: unknown osha: no
health hazards acute and chronic: c0rrosive to skin and eyes on contact
effects of overexposure: itching and burning sensation
medical cond aggravated by exposure: none specified by manufacturer.

First Aid

First aid: (eyes/skin)-flush w/running h2o for at least 15 min remove
contaiminated clothing & get medical attention immediately.

(ingestion)-do not induce vomiting, drink as much milk or h2o that
can be tolerat ed w/out vomiting and get medical attention.

(inhalation)-if inhaled remove to fresh air and get medical
attention immediately.

Chemical Properties

Boiling pt: b.P. Text: 230f,110c
vapor pres: 78% -100%
vapor density: 3.4 air=1
spec gravity: 1.240 to 1.275
solubility in water: yes 100%
appearance and odor: colorless & odorless

Reactivity

Stability indicator/materials to avoid: yes
do not store near organic materials of oxidizers. Do not store near or
introduce sources of combustion.

stability condition to avoid: overcharging at high temperatures and
spilling
hazardous decomposition products: hydrogen gas

Proper Disposal

Waste disposal methods: disposal must be in accordance with all
applicable local, state and federal regulations. coordinate with
supporting installation and/or macom environmental office prior to
disposal
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: sulfuric acid (sara iii) electrolite no other
ingredientsare specified via manufactures msds.

cas: 7664-93-9
rtecs #: ws5600000
other rec limits: none recommended
osha pel: 1 mg/m3
acgih tlv: 1 mg/m3; 9293
epa rpt qty: 1000 lbs