Storage Battery

NSN: 6140-01-304-3215 | Model: NW25811

A battery, composed of two or more cells forming a single unit, which may or may not be readily separable and which may be efficiently recharged by sending an electric current through the cells in a direction opposite that of the discharging current. the item may be furnished with integral charging facilities. for items which are composed of a single cell see cell, battery.

NSN Properties and Flags
NATO Stock Number
6140-01-304-3215
DEMIL
NO
Terminal Quantity
2
Terminal Type
Taper post
Battery Electrolyte
Lead acid
Cell Quantity
6
Voltage In Volts
12.0

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

NSN 6140-01-304-3215 Datasheet

Supply Class (FSC):
Rechargeable Batteries
Cross Reference:
  • NW25811
  • 12V-24C
Cage Codes:
  • Nmc/wollard, Inc. (CAGE 44185)
Schedule B & Trade:
  • Schedule B: 8507800002 (NAICS 335911)

    Storage batteries, nesoi

  • SITC: 77812

    Electric accumulators (storage batteries)

  • End Use: 20005

    Electric apparatus

Identification:
HMIC

Y - Indicates information is in the hazardous materials information resource system (hmirs).

PMIC

A - Item does not contain precious metal.

CRITL

- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Freight Information:
  • NMFC:

    060680 - Batteries or cell

  • WCC:

    582 - Batteries and parts (see 131), (vehicle parts)

  • SHC:

    9 - Other or no special handling required (sh)

  • ADC:

    A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.

  • ACC:

    H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)

  • LTL:

    W - Rating variable

  • TCC:

    W - Corrosive materials, un class 8 (corrosive label)

NSN Management Codes:
  • SOS
    Sms
  • AAC
    J
  • Quantity per pack
    1
  • Unit of Measure
    Ea
  • Shelf Life
    6 mo.
  • Classification Control
    U
  • MGMT_CTL
    9b----v
  • Repariability

Questions & Answers:

What are the historical prices recorded for this stock number?
Historical data shows pricing from $590.49 to $984.15..
Does NSN 6140-01-304-3215 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
Department Of The Navy, and Republic Of Korea
What is the NIIN of NSN 6140-01-304-3215?
013043215 or 01-304-3215
Does NSN 6140-01-304-3215 require demilitarization?
Yes - ITAR Controlled
What is the most recent solicitation for NSN 6140-01-304-3215?
No solicitations for this NSN.
When was this national stock number assigned to the federal catalog?
Jul 16, 1989
MSDS

Material Safety

MSDS BLFJD LEAD/ACID STORAGE BATTERY - HYBRID

Hazards

Routes of entry: inhalation: yes skin: yes ingestion: yes
reports of carcinogenicity: ntp: yes iarc: yes osha: yes
health hazards acute and chronic: acute: inhalation of acid vapors may
cause severe irritation or burns of the respiratory system,
pulmonary edema, or lung inflammation. May cause severe burns to
skin or eyes. Ingestion may cause sever e burns to mouth, throat,
and stomach. May affect kidney function. Chronic: may damage
lungs,teeth erosion.

explanation of carcinogenicity: arsenic is listed by iarc, ntp, & osha
as a carcinogen.

effects of overexposure: acid: severe irritation or burns to eyes, nose
and throat. Pulmonary edema, bronical emphysema, conjunctivitis,
stomatitis, dental erosion, nausea and vomiting. Lead: stomach
cramps, anemia and nerve da mage.

medical cond aggravated by exposure: persons with a history of ailments
or with a pre-existing disease involving the respiratory tract may
be at increased risk from exposure.

First Aid

First aid: inhalation: remove to fresh air. Resuscitate if not breathing.

get medical attention. Eyes: immediately flush with plenty of water
for 15 minutes holding eyelids open. Get medical attention.

skin: remove contaminated clothing. Wash with plentyof water for 15
minutes. Get medical advice. Ingestion: do not induce vomiting.

drink 1-2 glassses of water/milk if conscious. Get immediate
medical attention.

Chemical Properties

Hcc: c1
ph:
appearance and odor: lead/acid battery, polypropylene casing.

Reactivity

Stability indicator/materials to avoid: yes
strong oxidizing agents, combustibles, organic material, prolonged
overcharge.

stability condition to avoid: high heat, open flames .

hazardous decomposition products: oxides of sulfur, sulfuric acid fumes
and hydrogen gas.

Proper Disposal

Waste disposal methods: disposal should be made in accordance with all
applicable federal, state and local environmental regulations.Or
battery may be returned to reclamation centers.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: lead (sara iii)
cas: 7439-92-1
rtecs #: of7525000
fraction by wt: >60%
other rec limits: none specified
osha pel: 0.05 mg/m3;1910.1025
acgih tlv: 0.15 mg/m3;dust 9192
epa rpt qty: 1 lb
dot rpt qty: 1 lb

ingred name: antimony (sara iii)
cas: 7440-36-0
rtecs #: cc4025000
fraction by wt: >2%
other rec limits: none specified
osha pel: 0.5 mg/m3
acgih tlv: 0.5 mg sb/m3; 9192
epa rpt qty: 5000 lbs
dot rpt qty: 5000 lbs

ingred name: arsenic (sara iii)
cas: 7440-38-2
rtecs #: cg0525000
fraction by wt:
other rec limits: none specified
osha pel: 0.5 mg/m3 (as)
acgih tlv: 0.01,a1 mg/m3; 9394
epa rpt qty: 1 lb
dot rpt qty: 1 lb

ingred name: calcium, metal
cas: 7440-70-2
rtecs #: ev8040000
fraction by wt:
other rec limits: none specified

ingred name: sulfuric acid (sara iii)
cas: 7664-93-9
rtecs #: ws5600000
fraction by wt: 10-30%
other rec limits: none specified
osha pel: 1 mg/m3
acgih tlv: 1 mg/m3; 9192
epa rpt qty: 1000 lbs
dot rpt qty: 1000 lbs

ingred name: polypropylene
fraction by wt: 5%
other rec limits: none specified

MSDS CGLGF LEAD/ACID STORAGE BATTERY, NW25811

Hazards

Ld50 lc50 mixture: none specified by manufacturer.

routes of entry: inhalation: yes skin: yes ingestion: yes
reports of carcinogenicity: ntp: no iarc: yes osha: no
health hazards acute and chronic: rep contact w/h2so batt electrolyte
fluid may cause skin drying which may result in irrit/derm.Prol
mist of h2so4 inhal can cause inflamm of upper resp tract leading
to chronic bronchitis.Short term l iq/vap contact may result in eye
irrit/acid burns.Prol contact to strong acid fumes may result in
teeth enamel erosion.

explanation of carcinogenicity: per msds: ca porp 65.Epa- yes.Iarc-strong
inorg acid msit w/h2so4-catelog 1.Doesnt apply to liq forms/solns
in batt.

effects of overexposure: acid can cause irrit of
eyes,nose,throat.Breathing mist produces respiratory
difficulty,contacgt w/skin/eyes causes irrit & skin burn.

medical cond aggravated by exposure: none specified by manufacturer.

First Aid

First aid: sulfuric acid: inhal: move to ventilated area.Obtain med
attn.Eye: wash w/copious quantities of running water for
15mins.Opbtain med attn.Skin: flush area w/lg amts of running
water.Remove cotnam cloth & obtain med attn.Ingest: wash out mouth
w/running water.Dont induce vomiting.Call physician.

Chemical Properties

Hcc: c1
boiling pt: b.P. Text: supplement
melt/freeze pt: m.P/f.P text: supplementa
decomp temp: decomp text: np
vapor pres: supplement
vapor density: supplement
spec gravity: supplemental
ph:
viscosity: np
evaporation rate & reference: na
solubility in water: 100% solub electroly
appearance and odor: batt-polypropylene,hard rubb case,solid;pb-gray
metallic solid;electolyete(supp

Reactivity

Stability indicator/materials to avoid: yes
sparks,open flames.Keep battery case away from strong oxidizers.

stability condition to avoid: avoid overcharging & smoking, or sparks
near battery surface.

hazardous decomposition products: an explo hydrogen/oxygen mixture w/in
battery may occur during charging.

Proper Disposal

Waste disposal methods: contains toxic chem subj to reporting reqmts of
sec 313 title ii sara/40cfr372.Return whle scrap batt to
distributor/mfg/pb smelter for recycl.Neutra spills place residue
into cntrns w/sorbent matl,sa nd,earth for dispo.Contact loc &/or
state(supple)
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: lead (sara 313) (cercla)/lead oxide/lead sulfate
cas: 7439-92-1
rtecs #: of7525000
fraction by wt: 60%
other rec limits: none recommended
osha pel: see 1910.1025
acgih tlv: 0.05mg/m3, a3; 9596
epa rpt qty: 1 lb
dot rpt qty: 1 lb

ingred name: antimony (sara 313) (cercla)
cas: 7440-36-0
rtecs #: cc4025000
fraction by wt: 1-5%
other rec limits: none recommended
osha pel: 0.5 mg/m3
acgih tlv: 0.5 mg (sb)/m3; 9596
epa rpt qty: 5000 lbs
dot rpt qty: 5000 lbs

ingred name: arsenic (sara 313) (cercla)
cas: 7440-38-2
rtecs #: cg0525000
fraction by wt:
other rec limits: none recommended
osha pel: see 1910.1018
acgih tlv: 0.01 mg/m3, a1; 9596
epa rpt qty: 1 lb
dot rpt qty: 1 lb

ingred name: sulfuric acid (sara 302/313) (cercla)
cas: 7664-93-9
rtecs #: ws5600000
fraction by wt: 10-38%
other rec limits: none recommended
osha pel: 1 mg/m3
acgih tlv: 1 mg/m3/3 stel; 9596
epa rpt qty: 1000 lbs
dot rpt qty: 1000 lbs

ingred name: calcium, metal
cas: 7440-70-2
rtecs #: ev8040000
fraction by wt:
other rec limits: none recommended