A battery, composed of two or more cells forming a single unit, which may or may not be readily separable and which may be efficiently recharged by sending an electric current through the cells in a direction opposite that of the discharging current. the item may be furnished with integral charging facilities. for items which are composed of a single cell see cell, battery.
Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.
Storage batteries, nesoi
Electric accumulators (storage batteries)
Electric apparatus
Y - Indicates information is in the hazardous materials information resource system (hmirs).
PMICA - Item does not contain precious metal.
CRITL- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
060680 - Batteries or cell
582 - Batteries and parts (see 131), (vehicle parts)
9 - Other or no special handling required (sh)
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
C - Chemical corps items and all other chemicals not covered in other classificatons. note: when an item has a chemical proper shipp
W - Rating variable
W - Corrosive materials, un class 8 (corrosive label)
Questions & Answers: |
|
What are the historical prices recorded for this stock number? | |
Historical data shows pricing from $12,421.64 to $20,702.73.. | |
Does NSN 6140-01-323-1328 have a shelf life? | |
No. There is no shelf life applicable for this NSN. | |
What NATO entities are users of this NSN? | |
Department Of The Navy | |
What is the NIIN of NSN 6140-01-323-1328? | |
013231328 or 01-323-1328 | |
Does NSN 6140-01-323-1328 require demilitarization? | |
Yes - ITAR Controlled | |
What is the most recent solicitation for NSN 6140-01-323-1328? | |
No solicitations for this NSN. | |
When was this national stock number assigned to the federal catalog? | |
Jul 21, 1990 |
Ld50 lc50 mixture: ld50 (oral, rat) 2140 mg/kg
routes of entry: inhalation: yes skin: no ingestion: yes
reports of carcinogenicity: ntp: yes iarc: yes osha: yes
health hazards acute and chronic: acute ; tissue destruction on contact.
may cause 2nd and 3rd degree burns or blindness. Ingestion will
cause corrosive burns on contact. May be fatal if swallowed.
chronic - inhalation of mists may ca use upper respiratory
irritation.
explanation of carcinogenicity: contains arsenic and lead.
effects of overexposure: irritation and burning of exposed tissues
medical cond aggravated by exposure: respiratory disorders may be
aggravated by prolonged inhalation of mists.
First aid: obtain medical attention immediately. Inhaled: remove from
exposure to fresh air immediately. If not breathing, give
artificial respiration. If breathing is difficult, give oxygen.
eyes: immediately flush eye with plenty of water for at least 15
minutes. Occasionally lifting the upper and lower lids. do not
allow victim to rub or keep eyes closed. Skin: flush with large
amount of running water f or at least 15 minutes. Ingestion: do not
induce vomiting. If victim is conscious and alert, wash out mouth
with running water. Drink large amount of milk or water.
Hcc: c1
boiling pt: =112.8c, 235.F
vapor pres: 1 mm @ 145.8
vapor density: >1 (air=1)
spec gravity: acid = 1.285 +/- .010
evaporation rate & reference:
solubility in water: 100 %
appearance and odor: colorless, oily fluid/ acrid odor when hot
Stability indicator/materials to avoid: yes
strong alkaline materials, conductive metals, organic solvents
stability condition to avoid: overheating, overcharging which result in
acid mist / hydrogen generation, sparks, open flames
hazardous decomposition products: in fire, it may emit co, co2 and
sulfur oxides.
Waste disposal methods: this battery is recyclable. It is illegal to
dispose of lead-acid batteries by any means other than recycling. C
& d provides an environmentally responsible nation wide lead acid
battery collection an d recycling program. Contact your local c & d
sales representative for more information. Hazardous w aste codes:
d002, d008
Ingred name: lead, lead compounds
cas: 7439-92-1
rtecs #: of7525000
minumum % wt: 65.
maxumum % wt: 70.
other rec limits: none recommended
osha pel: 0.05 mg/m3
acgih tlv: 0.15 mg/m3
epa rpt qty: 1 lb
dot rpt qty: 1 lb
ingred name: sulfuric acid
cas: 7664-93-9
rtecs #: ws5600000
minumum % wt: 11.
maxumum % wt: 14.
osha pel: 1 mg/m3
acgih tlv: 1 mg/m3
acgih stel: 3 mg/m3
epa rpt qty: 1000 lbs
dot rpt qty: 1000 lbs
ingred name: antimony
cas: 7440-36-0
rtecs #: cc4025000
minumum % wt: 1.
maxumum % wt: 2.
osha pel: 0.5 mg/m3
acgih tlv: 0.5 mg/m3
epa rpt qty: 5000 lbs
dot rpt qty: 5000 lbs
ingred name: arsenic
cas: 7440-38-2
rtecs #: cg0525000
< wt: 1.
osha pel: 0.5 mg/m3
acgih tlv: 0.01 mg/m3
epa rpt qty: 1 lb
dot rpt qty: 1 lb
ingred name: copper
cas: 7440-50-8
rtecs #: gl5325000
< wt: 1.
osha pel: 1 mg/m3
acgih tlv: 1 mg/m3
epa rpt qty: 5000 lbs
dot rpt qty: 5000 lbs
ingred name: water
cas: 7732-18-5
rtecs #: zc0110000
minumum % wt: 3.5
maxumum % wt: 4.5
ingred name: inert components
minumum % wt: 10.
maxumum % wt: 15.