Secure Ordering: +1 (757) 528-8028
NationalStockNumber.info
NationalStockNumber.INFO

Worldwide distributor of NSN parts and consumables located in the USA.

Fluorescent Lamp

NSN: 6240-00-152-2982 | Model: F15T8CW

An item which produces light due to an ionized gas activating a fluorescent coating.

NSN Properties and Flags
NATO Stock Number
6240-00-152-2982
DEMIL
NO
Overall Length
18.000 inches
Average Life Rating In Hours
7500.0
End Application
Test station, oq-29 (v)msm; landing craft air cushion (lcac); radar set, firefinder (an/tpq-36); los angeles class ssn (688); sturgeon class ssn (637); repair facility. Oa8991; forrestal class cv; telephone circuit switch, an/ttc-39; ticonderoga class cg (47) ; central message switch, an/tyc-39a; pathfinder class t-ags 60
Emitted Light Characteristic
White, cool
Starting Characteristic
Preheat
Wattage Rating
15.000 watts
Base Style
Medium bipin (fluorescent)
Bulb Style
T (tubular)
Bulb Designator
T-8
Rated Average Life
Hours
Special Features
Energy saver
Specification Data
08108-f15t8/cw manufacturers standard

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

NSN 6240-00-152-2982 Datasheet

Supply Class (FSC):
Electric Lamps
Cross Reference:
  • F15T8CW
  • MS15589-6
  • P15TB/CW
  • MS15589-5
  • ANSI C78.2-1978
  • F15T8/CW
  • F15T8/CW
  • F15T8/SL
  • F15T8/CW-SK
  • F15T8/CW
  • F15T8/CW
  • 10652862
  • 9026787
  • 78-8453-8501-8
  • F15T8/CW
  • SM-A-838673-1
  • SM-A-838673
  • W-L-00116/9A
  • 78-8453-8501-8
  • 259839
  • A-A-1846
  • 78-8453-8501-8
  • 1296-01
  • 78-8453-8501-8
  • 78-8453-8501-8
  • 259839
  • 1054-316-33
  • F15TA/CW
  • 78-8453-8501-8
  • F15T8/CW
Cage Codes:
  • Zf Industrieantriebe Witten Gmbh (CAGE D9182)
  • Osram Sylvania Inc (CAGE 52343)
  • Military Specifications (CAGE 81349)
  • American National Standards (CAGE 80204)
  • Gte Products Corp (CAGE 88204)
  • Marvel Lamp Co Inc (CAGE 06172)
  • 21st Century Enterprises Inc (CAGE 56589)
  • Q S R Industrial Supply Inc (CAGE 58940)
  • General Electric Company (CAGE 08805)
  • Lamp Industry (CAGE 08108)
  • U S Army Aviation and Missile (CAGE 18876)
  • 3m Deutschland Gmbh (CAGE D2607)
  • Us Army Communications & (CAGE 80063)
  • Federal Specifications (CAGE 81348)
  • 3m Company (CAGE 76381)
  • 3 Communications Corporation L (CAGE 1PQF4)
  • Federal Commercial Item Description (CAGE 58536)
  • Imation Corp. (CAGE 39711)
  • Winchester Industries Inc (CAGE 28003)
  • Minnesota Mining and Mfg Co (CAGE 94862)
  • 3m Co Engineering Document Systems (CAGE 1BY21)
  • Raytheon Technical Services Company (CAGE 36378)
  • Visual Apollo Audio (CAGE 60837)
  • U S Lighting Corp (CAGE 58325)
  • Decisionone Corporation (CAGE 5H263)
  • Pegasus Savunma San. Ve Tic.ltd.sti. (CAGE T6976)
Replacements:
  • 6240-00-152-2982 replaces 6240-00-880-1346
  • 6240-00-152-2982 replaces 6240-01-123-0249
  • 6240-00-152-2982 replaces 6240-01-470-7630
Schedule B & Trade:
  • Schedule B: 9405400000 (NAICS 335129)

    Electric lamps and lighting fittings, nesoi

  • SITC: 81315

    Electric lamps and lighting fittings, n.E.S.

  • End Use: 20005

    Electric apparatus

Identification:
HMIC

Y - Indicates information is in the hazardous materials information resource system (hmirs).

PMIC

A - Item does not contain precious metal.

ADPE

- Represents items with no adp components

CRITL

- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Freight Information:
  • NMFC:

    109600 - Lamp (bulbs) elec fluorescent

  • WCC:

    761 - Electric lamps

  • SHC:

    9 - Other or no special handling required (sh)

  • ADC:

    A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.

  • ACC:

    H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)

  • LTL:

    J - 100.0

  • TCC:

    Z - No special type of cargo code applicable

NSN Management Codes:
  • SOS
    Sms
  • AAC
    D
  • Quantity per pack
    24
  • Unit of Measure
    Ea
  • Shelf Life
    N/A
  • Classification Control
    U
  • MGMT_CTL
    J2200x-
  • Repariability
    This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item.

Questions & Answers:

What are the historical prices recorded for this stock number?
Historical data shows pricing from $3.93 to $6.55..
Does NSN 6240-00-152-2982 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
Department Of The Army, Department Of The Air Force, National Security Agency, U.s. Marine Corps, Department Of The Navy, Defense Logistics Agency, Bureau Of Prisons, Federal Aviation Administration, U.s. Coast Guard, Veterans Administration, Austria, Poland, Brazil, Spain, Singapore, Kuwait, Malaysia, Australia, Canada, France, Germany, Republic Of Korea, Netherlands, Portugal, Greece, and Turkey
What is the NIIN of NSN 6240-00-152-2982?
001522982 or 00-152-2982
Does NSN 6240-00-152-2982 require demilitarization?
Yes - ITAR Controlled
What is the most recent solicitation for NSN 6240-00-152-2982?
No solicitations for this NSN.
When was this national stock number assigned to the federal catalog?
Jan 01, 1961
MSDS

Material Safety

MSDS CDXJN FLUORESCENT LAMP (STD COOL WHITE,WARM WHITE)

Hazards

Ld50 lc50 mixture: none specified by manufacturer.

routes of entry: inhalation: no skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: not applicable for intact
lamp.Breakage of lamp may result some expo to phosphor powder
dust/& to elemental mercury vapor.No adverse affects expected from
occasional expo to broken lamps,but as matter of good practice
prol/freq expo shuld be avoided thru use of adequ venti during
dispo of lg quant of lamp.

effects of overexposure: none specified by manufacturer.

medical cond aggravated by exposure: none specified by manufacturer.

First Aid

First aid: normal first aid procedure for glass cuts if such occur
through lamp breakage.

Chemical Properties

Hcc: n1
boiling pt: b.P. Text: na
melt/freeze pt: m.P/f.P text: na
decomp temp: decomp text: na
vapor pres: na
vapor density: na
spec gravity: na
ph: na
viscosity: na
evaporation rate & reference: na
solubility in water: na
appearance and odor: light bulb, 8ft long,up to 1.5" diameter.

percent volatiles by volume: na
corrosion rate: na

Reactivity

Stability indicator/materials to avoid: yes
glass will react w/hydrofluoric acid.

stability condition to avoid: under extreme heat glass envelope might
melt or crack.

hazardous decomposition products: none specified by manufacturer.

Proper Disposal

Waste disposal methods: under new tclp promulgated by epa tests of
used/spent fluorescent/incandesc/hi intens dischar lamps indicate
some type of these lamps may be classified as charact haz
waste.Notably tclp test result fo r fluorescent lamps vary
tremendously from (suppl)
disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: inert ingredients (glass, aluiminum, etc)
fraction by wt: 97%
other rec limits: none recommended

ingred name: phosphor powder
fraction by wt: 3%
other rec limits: none recommended

ingred name: fluorides
fraction by wt: 0.01%
other rec limits: none recommended

ingred name: antimony (sara 313) (cercla)
cas: 7440-36-0
rtecs #: cc4025000
fraction by wt: 0.01%
other rec limits: none recommended
osha pel: 0.5 mg/m3
acgih tlv: 0.5 mg (sb)/m3; 9596
epa rpt qty: 5000 lbs
dot rpt qty: 5000 lbs

ingred name: manganese (sara 313)
cas: 7439-96-5
rtecs #: oo9275000
fraction by wt: 0.02%
other rec limits: none recommended
osha pel: c, 5 mg/m3 (fume)
acgih tlv: 0.2 mg/m3; 9596

ingred name: mercury (sara 313) (cercla)
cas: 7439-97-6
rtecs #: ov4550000
fraction by wt: 0.01%
other rec limits: none recommended
osha pel: c, 0.1 mg/m3; z-2
acgih tlv: s,0.025 mg/m3; a4;96
epa rpt qty: 1 lb
dot rpt qty: 1 lb

ingred name: calcium phosphate crystal matrix, ingreds #2,3,4,5 are
tightly bound wihting this matrix
other rec limits: none recommended