Streptococcal Exoenzymes Antibody Determination Test Kit

NSN: 6550-01-146-2617 | Model: B6854-10
NSN Properties and Flags
NATO Stock Number
6550-01-146-2617
DEMIL
NO
Test Capability Quantity
50
Part Name Assigned By Controlling Agency
Test kit streptococcal enzyme antibody determinations 50 tests
Component Breakdown Within Each Test Kit
Vial containing 2.8 ml of sheep cells sensitized with streptococcus a extracellular angigens (streptozyme reagent)1; test tube containing lyophilized human serum (positive control)1; test tube containing lyophilized human serum (negative control)1; calibrated capillary tubes 50; capillary bulb 2; mirrored glass slide 1;
Special Features
Warning: contains sodium azide; note: g;

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

NSN 6550-01-146-2617 Datasheet

Supply Class (FSC):
Test Kits And Sets Reagents In Vitro Diagnostic Substances
Cross Reference:
  • B6854-10
  • CR-80
Cage Codes:
  • Cardinal Health 200, Llc (CAGE 07TA6)
  • Raiford Printing Company Inc (CAGE 5Y773)
Replacements:
  • 6550-01-146-2617 replaces 6550-01-203-3445
Schedule B & Trade:
  • Schedule B: 3822000002 (NAICS 325413)

    Diagnostic or lab reagents on a backing, prepared diag/lab reagents whether or not on a backing, not of heading 3002 or 3006; certified ref materials

  • SITC: 59869

    Composite diagnostic or laboratory reagents, n.E.S.

  • End Use: 12550

    Chemicals-other

Identification:
HMIC

Y - Indicates information is in the hazardous materials information resource system (hmirs).

PMIC

A - Item does not contain precious metal.

CRITL

- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Freight Information:
  • NMFC:

    058770 - Drugs/medicines/vitamins noi

  • WCC:

    534 - Medical supplies (not requiring temperature control)

  • SHC:

    9 - Other or no special handling required (sh)

  • ADC:

    A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.

  • ACC:

    M - Medical supplies, equipment, samples, records, etc.

  • LTL:

    W - Rating variable

  • TCC:

    Z - No special type of cargo code applicable

NSN Management Codes:
  • SOS
    Sms
  • AAC
    L
  • Quantity per pack
    1
  • Unit of Measure
    Ea
  • Shelf Life
    18 mo.
  • Classification Control
    U
  • MGMT_CTL
    C2201x-
  • Repariability

Questions & Answers:

What are the historical prices recorded for this stock number?
Historical data shows pricing from $1,059.84 to $1,766.41..
Does NSN 6550-01-146-2617 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
Turkey
What is the NIIN of NSN 6550-01-146-2617?
011462617 or 01-146-2617
Does NSN 6550-01-146-2617 require demilitarization?
Yes - ITAR Controlled
What is the most recent solicitation for NSN 6550-01-146-2617?
No solicitations for this NSN.
When was this national stock number assigned to the federal catalog?
Jan 26, 1983
MSDS

Material Safety

MSDS BPZKV 45D2, 45D4, 0R 45D6 STREPTOZYME

Hazards

Ld50 lc50 mixture: none specified by manufacturer.

routes of entry: inhalation: no skin: yes ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: the control sera have been prepared
from human blood that was nonreactive when tested for hepatitis b
surface antigen and hiv antibody. However, since no test method can
offer complete assurance, thes e controls and all blood specimens
should be handled as if capable of transmitting disease. Skin: (see
efts of overexp)
explanation of carcinogenicity: not relevant.

effects of overexposure: avoid skin contact with control serums. Eye:
avoid contact with eyes. Avoid swallowing contents.

medical cond aggravated by exposure: none specified by manufacturer.

First Aid

First aid: inhaled: not applicable skin: immediately wash with soap &
water. Eye: immediately flush with plenty of water. Ingested: contact
a physician.

Chemical Properties

Hcc: n1
appearance and odor: three part diagnostic test kit. Refer to package
insert.

Reactivity

Stability indicator/materials to avoid: yes
reagents in test kit contain sodium azide which may react w/lead or
copper plumbing to form highly explos metal azides.

stability condition to avoid: none specified by manufacturer.

hazardous decomposition products: poisonous gas is produced in fire.

Proper Disposal

Waste disposal methods: place matl in sealed contr & dispose of i/a/w
applic fed, st & loc regs. Avoid disp matl down drains. If occur,
flush w/ lg vol of h2o prevent azide buildup in copper/lead
plumbing. Decontamination pr oc are available from wampole lab,
techservices.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: sodium azide
cas: 26628-22-8
rtecs #: vy8050000
fraction by wt: 0.1%
osha pel: 0.1 ppm, c
acgih tlv: 0.11 ppm, c
epa rpt qty: 1000 lbs
dot rpt qty: 1000 lbs

MSDS CKSFJ 45D4, STREPTOZYME

Hazards

Health hazards acute and chronic: occupational exposure to this product
is not expected to produce adverse human health effects following
prudent workplace practices. Potential sensitization: this product
contains dry natural rubber ( in the dropper bulb, capillary tube
bulb, and in the vial stopper).

First Aid

First aid: for ingestion, seek immediate medical attention. For eye
contact, flush with plenty of water and seek medical attention. For
skin contact, wash with soap and water.

Chemical Properties

Hcc: t6
appearance and odor: test kit consisting of three reagents, calibrated
capillary tubes & bulbs.

Reactivity

Stability indicator/materials to avoid: yes
if disposed down a drain, the sodium azide in this kit may react with
lead and copper plumbing to form highly exposive metal azides.

hazardous decomposition products: if involved in a fire, poisonous gas
may be produced by the packaging materials.

conditions to avoid polymerization: will not occur.

Proper Disposal

Waste disposal methods: place material in a sealed container and dispose
of as medical/ infectious waste in accordance with applicable
environmental regulations.

Ingredients List

Ingred name: sodium azide (as preservative in positive in reagent and
controls.

cas: 26628-22-8
rtecs #: vy8050000
= wt: .1
acgih stel: c0.29 mg/m3
epa rpt qty: 1000 lbs
dot rpt qty: 1000 lbs

MSDS CKSFL 45D4, STREPTOZYME

Hazards

Health hazards acute and chronic: occupational exposure to this product
is not expected to produce adverse human health effects following
prudent workplace practices. Potential sensitization: this product
contains dry natural rubber ( in the dropper bulb, capillary tube
bulb, and in the vial stopper).

First Aid

First aid: for ingestion, seek immediate medical attention. For eye
contact, flush with plenty of water and seek medical attention. For
skin contact, wash with soap and water.

Chemical Properties

Hcc: t6
appearance and odor: test kit consisting of three reagents, calibrated
capillary tubes & bulbs.

Reactivity

Stability indicator/materials to avoid: yes
if disposed down a drain, the sodium azide in this kit may react with
lead and copper plumbing to form highly exposive metal azides.

hazardous decomposition products: if involved in a fire, poisonous gas
may be produced by the packaging materials.

conditions to avoid polymerization: will not occur.

Proper Disposal

Waste disposal methods: place material in a sealed container and dispose
of as medical/ infectious waste in accordance with applicable
environmental regulations.

Ingredients List

Ingred name: human source material (contained in negative controls)

MSDS CKSFP 45D4, STREPTOZYME

Hazards

Health hazards acute and chronic: occupational exposure to this product
is not expected to produce adverse human health effects following
prudent workplace practices. Potential sensitization: this product
contains dry natural rubber ( in the dropper bulb, capillary tube
bulb, and in the vial stopper).

First Aid

First aid: for ingestion, seek immediate medical attention. For eye
contact, flush with plenty of water and seek medical attention. For
skin contact, wash with soap and water.

Chemical Properties

Hcc: t6
appearance and odor: test kit consisting of three reagents, calibrated
capillary tubes & bulbs.

Reactivity

Stability indicator/materials to avoid: yes
if disposed down a drain, the sodium azide in this kit may react with
lead and copper plumbing to form highly exposive metal azides.

hazardous decomposition products: if involved in a fire, poisonous gas
may be produced by the packaging materials.

conditions to avoid polymerization: will not occur.

Proper Disposal

Waste disposal methods: place material in a sealed container and dispose
of as medical/ infectious waste in accordance with applicable
environmental regulations.

Ingredients List

Ingred name: human source material (contained in positive controls)