Worldwide distributor of NSN parts and consumables located in the USA.
A chemical used to reactivate a processing solution to its original working strength and volume. It does not include replenisher, x-ray film processing.
Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.
Apparatus and equipment for photographic labs nesoi
Apparatus and equipment for photographic (including cinematographic) laboratories, n.E.S.; negatoscopes; projection screens
Photo, service industry machinery
Y - Indicates information is in the hazardous materials information resource system (hmirs).
PMICU - Precious metal content is unknown
CRITL- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Questions & Answers: |
|
What are the historical prices recorded for this stock number? | |
No pre-dated pricing for this NSN could be found. | |
Does NSN 6750-01-168-4562 have a shelf life? | |
No. There is no shelf life applicable for this NSN. | |
What NATO entities are users of this NSN? | |
National Aeronautics and Space Administration | |
What is the NIIN of NSN 6750-01-168-4562? | |
011684562 or 01-168-4562 | |
Does NSN 6750-01-168-4562 require demilitarization? | |
Yes - ITAR Controlled | |
What is the most recent solicitation for NSN 6750-01-168-4562? | |
No solicitations for this NSN. | |
When was this national stock number assigned to the federal catalog? | |
Dec 19, 1983 |
ld50 lc50 mixture: none specified by manufacturer.
route of entry inds - inhalation: yes
skin: no
ingestion: yes
carcinogenicity inds - ntp: no
iarc: no
osha: no
effects of exposure: eye: may cause irrit. (long-term expos to hydroquinone
dust/vap can cause visual impairment, due to low conc of hydroquinone in prod
& unlikelihood of long-term expos, this effect is not anticipated).
skin: may cause irrit. May cause allergic skin rxn in some individuals &
loss of skin pigment on rptd,(efts of overexp)
explanation of carcinogenicity: not relevant
signs and symptions of overexposure: hlth haz: prlng cont. Inhal: vap may cause
resp sys irrit. (sulfite can cause sev asthmatic rxn in some individuals, due
to physical nature of prod this eft is not anticipated). Ingest: may cause
dige st sys irrit. May be harmful/fatal if swallowed. Symp may incl naus,
vomit, drow, ringing in ears, dizz, (supp data)
medical cond aggravated by exposure: none specified by manufacturer.
first aid: eye: flush with plenty of water for at least 15 minutes and contact
a physician. Skin: wash affected area with soap and water. Inhal: move to
fresh air. Ingest: immediately induce vomiting and contact a physician or
poison control center.
b.P. Text: >212f,>100c
vapor pres: 17.5@68f
spec gravity: 1.272
ph: supdat
solubility in water: complete
appearance and odor: clear, light yellow liquid, odorless.
percent volatiles by volume: >50
product id: sqr lith processor replenisher part ar
cage: 1by21
company name: minnesota mining and mfg co engineering document systems div
street: 3m ctr
city: saint paul mn
zipcode: 55144-1000
health emergency phone: 612-733-1110
label required ind: y
date of label review: 08/03/1992
status code: c
label date: 08/03/1992
origination code: g
eye protection ind: yes
skin protection ind: yes
signal word: caution
respiratory protection ind: yes
health hazard: slight
contact hazard: slight
fire hazard: none
=======================================================
responsible party cage: 1by21
trans id no: 112666
product id: sqr lith processor replenisher part ar
msds prepared date: 02/13/1991
review date: 01/19/1993
mfn: 1
multiple kit number: 0
review ind: y
Hazard and precautions: protect from freezing. Avoid eye/skin cont, brthg
vaps/mists & do not take internally. Acute: eye cont: may cause irrit.
skin cont: may cause irrit & allergic rxn in some individuals. May cause
loss o f skin pigment on rptd, prlngd cont. Inhal: vap may cause resp sys
irrit. Ingest: may cause digest sys irrit. May be harmful/fatal if swallowed.
symp may incl naus, vomit, drow, ringing in ears, dizz, abdom pain,
convulsions, muscular twitching, mental confusion, hdch, pale/bluish skin,
brthg dfclty, circulatory collapse & death. Sulfites can cause severe
asthmatic reactions in some individuals. C hronic: none listed may
manufacturer.
spill release procedures: collect large spills. Flush small spills to sewer
with water. Wash spill area with water to remove residues.
neutralizing agent: none specified by manufacturer.
waste disposal methods: sm qty (5 gal) of waste generally can be discharged
along with other facility wastes to a wastewater treatment system. Since
regulations vary, consult applicable federal, state and local regulations o r
authorities before disposal.
handling and storage precautions: avoid eye/skin cont. Wear prot gloves when
hndlg. Launder contamd clthg before reuse. Avoid prlng/rptd brthg of
vap/mist. Do not take internally.
other precautions: keep out of reach of children. Protect from freezing.