Technical Dichlorodifluoromethane

NSN: 6830-00-602-2357 | Model: BB-F-1421
NSN Properties and Flags
NATO Stock Number
6830-00-602-2357
DEMIL
NO
Physical Form
Gas
Impurities Limitation In Percent
High boiling max 0.01
Special Features
Can has push button valve and 6 inch polyethylene nozzle
Nondefinitive Specification/std Data
12 type

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

NSN 6830-00-602-2357 Datasheet

Supply Class (FSC):
Gases: Compressed And Liquefied
Cross Reference:
  • BB-F-1421
  • 073163
  • 11555-10
Cage Codes:
  • Federal Specifications (CAGE 81348)
  • Curtin Matheson Scientific Inc (CAGE 11876)
Schedule B & Trade:
  • Schedule B: 2903770050 (NAICS 325120)

    Dichlorodifluoromethane

  • SITC: 51138

    Halogenated derivatives of acyclic hydrocarbons containing two or more different halogens

  • End Use: 12540

    Chemicals-organic

Identification:
HMIC

Y - Indicates information is in the hazardous materials information resource system (hmirs).

PMIC

A - Item does not contain precious metal.

CRITL

- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Freight Information:
  • NMFC:

    085540 - Air in steel cylinders

  • WCC:

    634 - Cylinders, compressed gas, filled or empty

  • SHC:

    9 - Other or no special handling required (sh)

  • ADC:

    A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.

  • ACC:

    C - Chemical corps items and all other chemicals not covered in other classificatons. note: when an item has a chemical proper shipp

  • TCC:

    G - Nonflammable compressed gas, un class 2 (nonflammable gas label; except: (1) oxygen which requires an oxidizer label, and (2) fl

  • LTL:

    Q - 70.0

NSN Management Codes:
  • SOS
    Sms
  • AAC
    V
  • Quantity per pack
    No qup
  • Unit of Measure
    Cn
  • Shelf Life
    N/A
  • Classification Control
    U
  • MGMT_CTL
    J2200x-
  • Repariability
    This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item.

Questions & Answers:

What are the historical prices recorded for this stock number?
Historical data shows pricing from $20.33 to $33.89..
Does NSN 6830-00-602-2357 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
Singapore, Republic Of Korea, and Greece
What is the NIIN of NSN 6830-00-602-2357?
006022357 or 00-602-2357
Does NSN 6830-00-602-2357 require demilitarization?
Yes - ITAR Controlled
What is the most recent solicitation for NSN 6830-00-602-2357?
No solicitations for this NSN.
When was this national stock number assigned to the federal catalog?
Jan 18, 1975
MSDS

Material Safety

MSDS BFHRJ MS-220 AERO-DUSTER

Hazards

Routes of entry: inhalation: yes skin: yes ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: eyes: liquid contact can cause
frostbite. Skin: liquid contact can cause frostbite. Inhalation:
vapor may cause light-headedness, giddiness, shortness of breath,
and may lead to narcosis, cardiac irre gularities, unconsciousness
or death. Ingestion: no major health hazards detected in tests on
animals.

effects of overexposure: eyes: irritation, frostbite. Skin: irritation,
fostbite. Inhalation: light-headedness, giddiness, shortness of
breath, narcosis, cardiac irregularities, unconsciousness, death.

ingestion: no symptoms.

medical cond aggravated by exposure: none specified by manufacturer.

First Aid

First aid: eyes: flush with large amounts of water. Get medical
attention. Skin: flush area with large amounts of water. Treat for
frostbite. Inhalation: move to fresh air. If not breathing give
cpr. If breathin g difficult give oxygen. Do not give epinephrine
or similar drugs. Ingestion: ingestion not likely to occur since
product is a gas at ambient temperature and pressure.

Chemical Properties

Hcc: v2
boiling pt: b.P. Text: -22f,-30c
vapor pres: 80 psig
vapor density: 4.2
spec gravity: 1.311
ph: 7
evaporation rate & reference: >8 (ether=1)
solubility in water: negligible
appearance and odor: clear, colorless liquefied gas. Slight ethereal
odor.

percent volatiles by volume: 100

Reactivity

Stability indicator/materials to avoid: yes
alkali or alkaline earth metals; powdered aluminum, zinc, beryllium,
etc.

stability condition to avoid: avoid open flames and high temperatures.

hazardous decomposition products: can be decomposed by high temperatures
forming hydrofluoric acids, possible carbonyl halides.

conditions to avoid polymerization: will not occur.

Proper Disposal

Waste disposal methods: dispose of waste in accordance with local, state
and federal regulations. Do not puncture or incinerate aerosol
cans. Disposal service to landfill is appropriate.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: dichlorodifluoromethane (sara iii)
cas: 75-71-8
rtecs #: pa8200000
fraction by wt: 100%
other rec limits: none specified
osha pel: 1000 ppm
acgih tlv: 1000 ppm; 9192
epa rpt qty: 5000 lbs
dot rpt qty: 5000 lbs
ozone depleting chemical: 1

MSDS BFHRK DICHLORODIFLUOROMETHANE

Hazards

Ld50 lc50 mixture: no death - ald rats >1,000 mg.Kg
routes of entry: inhalation: yes skin: yes ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: acute-inhalation: may cause
dizziness,shortness of breath,narcosis,cardiac irregularities,coma
or death.Eye/skin: may cause frostbite,skin irritation/reddening,eye
discomfort.Ingestion: may cause nausea & vomiting.Chronic-may cause
defatting of skin & dermatitis.

explanation of carcinogenicity: freon 12 is not listed as a carcinogen
by iarc, ntp or osha.

effects of overexposure: dizziness,shortness of breath,narcosis,cardiac
irregularities,coma or death.Eye/skin: may cause frostbite,skin
irritation/reddening,eye discomfort.Ingestion: may cause nausea &
vomiting.

medical cond aggravated by exposure: individuals with heart
(cardiovascular disease) or respiratory disorders may prove
especially susceptible.

First Aid

First aid: obtain medical assistance in all cases.Eyes/skin: flush with
water for at least 15 minutes.Inhalation: remove to fresh air.Give
oxygen/cpr if needed.**do not give epinephrine or similar
drugs**.Ingestio n: compound not normally considered hazardous.Do
not induce vomiting as the hazard of aspirating the material into
the lungs is a greater hazard than allowing it to pass through the
intestinal tract.

Chemical Properties

Hcc: v2
boiling pt: b.P. Text: -22f,-30c
vapor pres: 4138 @ 77f
vapor density: 4.2
spec gravity: 1.31
evaporation rate & reference: >1 (n-butyl acetate=1)
solubility in water: 0.03 %
appearance and odor: colorless liquefied gas; slight ethereal odor
percent volatiles by volume: 100

Reactivity

Stability indicator/materials to avoid: yes
alkali and alkaline earth metals, powdered al, zn, be or mg.

stability condition to avoid: avoid spraying near open flames or red hot
surfaces. Do not heat aerosol containers above 120 f/49 c.

hazardous decomposition products: hydrochloric, hydrofluoric and
possibly carbonyl halides

Proper Disposal

Waste disposal methods: used or unused products should be tested to
determine hazard status and disposal requirements under local,
state and federal regulations.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: dichlorodifluoromethane (sara iii)
cas: 75-71-8
rtecs #: pa8200000
fraction by wt: 100.00%
other rec limits: none specified
osha pel: 1000 ppm
acgih tlv: 1000 ppm; 9192
epa rpt qty: 5000 lbs
dot rpt qty: 5000 lbs
ozone depleting chemical: 1

MSDS BFHRM FREON 12

Hazards

Effects of overexposure: lt head,gidd,short of breath,narcosis,cardiac
arryth at high conc.

First Aid

First aid: eye/skin contact: flush w/wtr;call a physician/inh: remove to
fresh air,call a physician.Do not give epinephrine or similar
drugs.

Chemical Properties

Hcc: v2
boiling pt: b.P. Text: -21.6f,-30c
vapor pres: sup
vapor density: 6.33
spec gravity: 1.311
solubility in water: negligible
appearance and odor: colorless liquid,slight ethereal odor.

percent volatiles by volume: 100.

Reactivity

Stability indicator/materials to avoid: yes
avoid contact w/aluminum
stability condition to avoid: open flames or high temps.

hazardous decomposition products: hcl,hf,possibly carbonyl fluoride.

Proper Disposal

Waste disposal methods: reclaim by distillation.Or remove to a permitted
waste disposal facility.Comply w/all local,state,fed.Regs.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: dichlorodifluoromethane (sara iii)
cas: 75-71-8
rtecs #: pa8200000
fraction by wt: 100%.

osha pel: 1000 ppm
acgih tlv: 1000 ppm; 9192
epa rpt qty: 5000 lbs
dot rpt qty: 5000 lbs
ozone depleting chemical: 1

MSDS BGWCM FREON 12

Hazards

Routes of entry: inhalation: yes skin: no ingestion: no
health hazards acute and chronic: see signs and symptoms of
overexposure.

effects of overexposure: light-headedness, giddiness, shortness of
breath, possible narcosis, possible cardiac arrhythmias at high
concentrations.

medical cond aggravated by exposure: none stated

First Aid

First aid: inhale: remove to fresh air, call a physician, do not give
epinephrine or similar drugs; skin/eye: flush with water, call a
physician.

Chemical Properties

Hcc: g3
boiling pt: b.P. Text: -21.6f
vapor pres: 4893
vapor density: 6.33
spec gravity: 1.3
evaporation rate & reference: rapid
solubility in water: .028
appearance and odor: colorless liquid, slight ethereal odor.

percent volatiles by volume: 100

Reactivity

Stability indicator/materials to avoid: yes
none stated
stability condition to avoid: open flames or high temperatures.

hazardous decomposition products: hydrochloric & hydrofluoric acid,
possible carbonyl fluoride.

Proper Disposal

Waste disposal methods: contact your local environmental officer.Do not
puncture or incinerate container.Give to disposal service.Dispose
of in accordance with federal,state and local environmental
regulations.Full or partia lly filled containers are considered
hazardous.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: dichlorodifluoromethane (sara iii)
cas: 75-71-8
rtecs #: pa8200000
fraction by wt: 100%
osha pel: 1000 ppm
acgih tlv: 1000 ppm; 9192
epa rpt qty: 5000 lbs
dot rpt qty: 5000 lbs
ozone depleting chemical: 1