Secure Ordering: +1 (757) 528-8028
NationalStockNumber.info
NationalStockNumber.INFO

Worldwide distributor of NSN parts and consumables located in the USA.

Technical Carbon Monoxide

NSN: 6830-00-973-7286 | Model:
NSN Properties and Flags
NATO Stock Number
6830-00-973-7286
DEMIL
NO
Physical Form
Gas
Composition And Percentage
99.5 by weight carbon monoxide
Supplied Cylinder
Nonsupply item

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

NSN 6830-00-973-7286 Datasheet

Supply Class (FSC):
Gases: Compressed And Liquefied
Schedule B & Trade:
  • Schedule B: 2811299000 (NAICS 325180)

    Other inorganic oxygen compounds of nonmetals, nesoi

  • SITC: 52239

    Inorganic oxygen compounds of nonmetals, n.E.S.

  • End Use: 12530

    Chemicals-inorganic

Identification:
HMIC

Y - Indicates information is in the hazardous materials information resource system (hmirs).

PMIC

A - Item does not contain precious metal.

CRITL

- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Questions & Answers:

What are the historical prices recorded for this stock number?
No pre-dated pricing for this NSN could be found.
Does NSN 6830-00-973-7286 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
No recorded entities for this stock number.
What is the NIIN of NSN 6830-00-973-7286?
009737286 or 00-973-7286
Does NSN 6830-00-973-7286 require demilitarization?
Yes - ITAR Controlled
What is the most recent solicitation for NSN 6830-00-973-7286?
No solicitations for this NSN.
When was this national stock number assigned to the federal catalog?
Jan 01, 1962
MSDS

Material Safety

MSDS BGBCT CARBON MONOXIDE

Hazards

Ld50 lc50 mixture: lc50 inhal rat = 1807 ppm / 4 hours
routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: **poisonous** material is highly toxic
by reducing blood oxygen carrying capacity. Excessive exposure may
be fatal.

explanation of carcinogenicity: there are no ingredients above 0.1%
which are identified as carcinogens by ntp,iarc or osha.

effects of overexposure: symptoms of overexposure are shortness of
breath, headache, confusion, nausea, and dizziness.

medical cond aggravated by exposure: persons with pre-existing
respiratory ailments may be at increased risk from exposure.

First Aid

First aid: inhal: immediately remove victim to fresh air. Lay on stomach
with head to side. If breathing administer oxygen. If not
breathing, administer artificial respiration and oxygen
simultaneously. Get medic al attention immediately.

Chemical Properties

Hcc: g1
boiling pt: b.P. Text: -313f,-192c
melt/freeze pt: m.P/f.P text: -341f,-207c
vapor density: 0.968
spec gravity: 0.789
solubility in water: insoluble
appearance and odor: gas;colorless;odorless.

percent volatiles by volume: 100

Reactivity

Stability indicator/materials to avoid: yes
noncorrosive oxidizing materials, brf*3, cs*2o, if*7, nf*3, o*2, of*2,
ag*2o.

stability condition to avoid: high heat,sources of ignition.

hazardous decomposition products: manufacturer states none.

Proper Disposal

Waste disposal methods: dispose of in accordance with federal,state and
local regulations.Return cylinders,with caps and plugs secure,to
supplier.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: carbon monoxide
cas: 630-08-0
rtecs #: fg3500000
fraction by wt: 100.0%
osha pel: 50 ppm
acgih tlv: 25 ppm; 9293

MSDS BGBCV CARBON MONOXIDE

Hazards

Ld50 lc50 mixture: lclo human 4000ppm/30 min
routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: acute: material highly toxic by
reduction of blood's oxygen carying capacity. Excessive exposure
may be fatal. Chronic: none.

effects of overexposure: shortness of breath, headache, confusion,
nausea and dizziness.

medical cond aggravated by exposure: respiratory problems.

First Aid

First aid: inhal: remove to fresh air. Lay on stomach w/head to side. If
breathng administer oxygen. If not breathing, administer artificial
respiration and oxygen simultaneously.

Chemical Properties

Hcc: g8
boiling pt: b.P. Text: -310f,-190c
vapor density: 0.968
spec gravity: 0.789 @191.5c
solubility in water: insoluble
appearance and odor: odorless, colorless gas
percent volatiles by volume: 100

Reactivity

Stability indicator/materials to avoid: yes
noncorrosive oxidizing materials, brf3, cs2o, clf3, if7, nf3, o2, of2,
ag2o.

stability condition to avoid: none specified by manufacturer.

hazardous decomposition products: none

Proper Disposal

Waste disposal methods: return cylinders to supplier w/valve outlet
plugs or caps secured & valve protection cap in place. Remove
leaking cylinder to remote area to emtpy. Waste co can be piped to
approved incinerator or tan k can be place in pit to burn co to
co2.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: carbon monoxide
cas: 630-08-0
rtecs #: fg3500000
fraction by wt: 100%
other rec limits: none recommended
osha pel: 35 ppm
acgih tlv: 50 ppm

MSDS BKYQK GASEOUS CARBON MONOXIDE

Hazards

Routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: inhalation: headache, nausea, coma,
death & asphyxia.

explanation of carcinogenicity: none
effects of overexposure: inhalation: headache, nausea, coma, death,
asphyxia.

First Aid

First aid: inhalation: remove to fresh air. If breathing has stopped,
give artificial respiration. Administer oxygen. Keep victim warm &
at rest. Obtain medical attention in all cases.

Chemical Properties

Boiling pt: b.P. Text: -312.7f
vapor density: 0.968
spec gravity: 0.793
solubility in water: 2.32%
appearance and odor: colorless & gas odorless.

percent volatiles by volume: 100%

Reactivity

Stability indicator/materials to avoid: yes
oxidizers
stability condition to avoid: heat, sources of ignition, sparks, flames,
physical damage.

Proper Disposal

Waste disposal methods: dispose of in accordance w/local, state, &
federal regulations.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: carbon monoxide
cas: 630-08-0
rtecs #: fg3500000
fraction by wt: 98%
other rec limits: 50 ppm
osha pel: 50 ppm
acgih tlv: 25 ppm; 9293

MSDS BNQCL CARBON MONOXIDE

Hazards

Routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: all the disorders are due to markedly
reduced cellular respiration and may include central nervous system
impairment, cardiovascular collapse, renal insufficiency, coma,
etc.

explanation of carcinogenicity: this compound contains no ingredients at
concentrations of 0.1% or greater that are carcinogens or suspect
carcinogens.

effects of overexposure: depending on levels and duration of exposure,
sympoms may include headache, dizziness, heart palpitations
weakness, confusion and nausea to convulsions, eventual
unconsciousness and death.

medical cond aggravated by exposure: none specified by manufacturer.

First Aid

First aid: conscious persons shouldbe assisted to an uncontaminated area
and be treated with supplemental oxygen. Quick removal from the
contaimnated area is most important. Unconscious persons should be
moved t o an uncontaimnated area and be given artificial
respiration and oxygen at the same time. The administering of
oxygen at elevated pressure has shown to be beneficial as a
hyperbaric chamber.

Chemical Properties

Hcc: g2
boiling pt: b.P. Text: -312f,-191c
melt/freeze pt: m.P/f.P text: -337f,-205c
vapor pres: >220.4
spec gravity: 0.96
solubility in water: slight
appearance and odor: colorless gas, odorless gas.

Reactivity

Stability indicator/materials to avoid: yes
oxidizers.

stability condition to avoid: none
hazardous decomposition products: carbon monoxide.

Proper Disposal

Waste disposal methods: do not attempt to dispose of waste or unused
quaantities. Return in the shipping container properly labeled,
with any valve outlet plugs or caps secured and valve protection
cap in place to airco for proper disposal.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: carbon monoxide
cas: 630-08-0
rtecs #: fg3500000
fraction by wt: 100.000%
other rec limits: none specified
osha pel: 50 ppm
acgih tlv: 25 ppm; 9293

MSDS BVPZL CARBON MONOXIDE

Hazards

Ld50 lc50 mixture: none specified by manufacturer.

routes of entry: inhalation: yes skin: no ingestion: no
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: acute: ingest: highly unlikely rte of
expos. Skin/eye cont/skin absorption: no evid of adverse efts from
avail info. Inhal: depending on conc & duration of expos, may cause
hdch, drow, dizz, excitation, r apid brthg, pallor, cyanosis,
excess salivation, naus, vomit, hallucinations, confusn, angina,
convls &(efts of overexp)
explanation of carcinogenicity: not relevant
effects of overexposure: hlth haz: uncon. With well established pois,
mucosal surf will be bright red (cherry red) in color. Lack of
oxygen can cause death. Chronic: rptd hypoxia from co expos will
cause gradually incr cns dmg, w/loss of sensation in fingers, poor
memory & mental deterioration. Chronic expos may facilitate devel
of (ing 5)
medical cond aggravated by exposure: due to hypoxia from
carboxyhemoglobin formation, may aggravate established coronary &
cerebral circulatory insufficiency.

First Aid

First aid: ingest: call md immed. Skin: wash w/soap & water. Inhal: remove
to fresh air. Give artf resp if not brthg. Give oxygen if brthg is
dfclt. Call md. Eye: flush w/water for at lst 15 mins. Notes to md:
there is no specific antidote. Treatment of overexp should be
directed at control of symps & clinical cndtn of patient. Angina &
depress of st segment of electrocardiogram indicated myocardial
(ing 9)

Chemical Properties

Boiling pt: b.P. Text: -313f,-192c
melt/freeze pt: m.P/f.P text: -341f,-207c
vapor pres: gas
vapor density: 0.968
spec gravity: gas
solubility in water: negligible
appearance and odor: colorless gas at normal temperature & pressure;
odorless.

percent volatiles by volume: 100

Reactivity

Stability indicator/materials to avoid: yes
oxidizing agents, oxygen, flammables, metal oxides, metals in presence
of moisture &/or sulfur compounds.

stability condition to avoid: temperatures in excess of 400c.

hazardous decomposition products: carbon monoxide will decompose to form
carbon dioxide & carbon >400c.

Proper Disposal

Waste disposal methods: prevent waste from contaminating surrounding
environment. Keep personnel away. Discard any product, residue,
disposable container or liner in an environmentally acceptable
manner, in full compliance w /federal, state & local regulations.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: carbon monoxide
cas: 630-08-0
rtecs #: fg3500000
fraction by wt: 100%
osha pel: 50 ppm, c;200 ppm
acgih tlv: 25 ppm

ingred name: supdat: flamm vaps may spread from spill. Explo atms may
linger. Before entering area, esp confined areas, check (ing 3)
rtecs #: 9999999zz

ingred name: ing 2: atm w/approp device. No part of cntnr should be
subjected to temp >52c (approx 125f). Most cntnrs are (ing 4)
rtecs #: 9999999zz

ingred name: ing 3: provided w/press relief device designed to vent
contents when they are exposed to elevated temperature.

rtecs #: 9999999zz

ingred name: efts of overexp: atheroschierosis. Other efts incl
embryotox, impaired cardiovascular function, pneum, gross (ing 6)
rtecs #: 9999999zz

ingred name: ing 5: neuropsychiatric dmg, memory impairment, perm cns dmg
& cerebral edema w/irreversible brain dmg. Late fatal(ing 7)
rtecs #: 9999999zz

ingred name: ing 6: demyelinization is rare, but poss complication.

carbon monoxide prdces embryofetal tox in lab animals, but (ing 8)
rtecs #: 9999999zz

ingred name: ing 7: only at doses which cause maternal tox. There is no
info avail w/respect to poss efts in humans.

rtecs #: 9999999zz

ingred name: first aid proc: hypoxia. Expos to high concs can rslt in
cerebral edema. With sev doses, use of hyperbaric oxygen(ing 10)
rtecs #: 9999999zz

ingred name: ing 9: may be beneficial. Individuals repeatedly overexposed
may present positive romberg's sign.

rtecs #: 9999999zz

ingred name: spill proc: leak/move leaking cntnr to well-ventilated area.

flamm tox gas may spread from spill. Before entering(ing 12)
rtecs #: 9999999zz

ingred name: ing 11: area, especially confined areas, check atmosphere
w/appropriate device.

rtecs #: 9999999zz

ingred name: other prec: explo-proof equip. Keep away from heat, spks &
open flame. Store & use w/adeq vent at all times. Use (ing 14)
rtecs #: 9999999zz

ingred name: ing 13: only in clsd sys. Close valve when not in use & when
empty. Keep away from oxidizing agents. When two/ (ing 15)
rtecs #: 9999999zz

ingred name: ing 14: more gases/liquefied gases are mixed, their haz
properties may combine to create addnl unexpected hazs.(ing 16)
rtecs #: 9999999zz

ingred name: ing 15: obtain & evaluate sfty info for each component
before you prdce mixt. Consult indus hygienist/other (ing 17)
rtecs #: 9999999zz

ingred name: ing 16: trained pers when you make your sfty eval of end
prod. Remember, gases & liqs have properties which can (ing 18)
rtecs #: 9999999zz

ingred name: ing 17: cause serious injury/death. Be sure to read &
understand all lbls & other instructions supplied w/all (ing 19)
rtecs #: 9999999zz

ingred name: ing 18: containers of this product.

rtecs #: 9999999zz

ingred name: resp prot: niosh/msha approved scba operated in
pressure-demand mode.

rtecs #: 9999999zz