Adhesive

NSN: 8040-01-254-0300 | Model: SPEEDBONDER 325

A substance compounded for binding materials together by surface attachment. It is not used primarily to fill voids or pores or for sealing purposes. Excludes canada balsam; cement, watch jewel; film cement, photographic; gasket cement; and gasket shellac compound.

NSN Properties and Flags
NATO Stock Number
8040-01-254-0300
DEMIL
NO
Physical Form
Liquid
Quantity Within Each Unit Package
50.000 milliliters
Specific Usage Design
For bonding metal or ceramic close fitting rigid parts exposed to thermal cycling such as in electric motor assemblies
Special Features
Service temperature range of minus 65 degrees f to plus 350 degrees f
Color
Amber
Material
Plastic acrylic
Supplementary Features
50 milliliter bottle
Recent Solicitations
Solicitation Return by Date Buyer Code Quantity
SPE8ES21T3655 2021-04-07 PEPCE 3 BT
SPE8ES20T4762 2020-05-04 PEPCE 1 BT
SPE8ES20T4202 2020-04-13 PEPCE 2 BT
SPE8ES20T3171 2020-03-09 PEPCE 1 BT
SPE8ES20T3135 2020-03-09 PEPCE 1 BT
SPE8ES20T2713 2020-02-24 PEPCE 2 BT
SPE8ES20T1855 2020-01-13 PEPCE 1 BT
SPE8ES20T1606 2019-12-24 PEPCE 10 BT
SPE8ES20T0541 2019-11-05 PEPCE 5 BT
SPE8ES19T5533 2019-05-28 PEPCE 1 BT

Inventory Check

The last inventory check on this NSN was done on 08/16/2023. Due to rapid changes in inventory this may not be the current stock qty.

  • New: 1

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

NSN 8040-01-254-0300 Datasheet

Supply Class (FSC):
Adhesives
Cross Reference:
  • SPEEDBONDER 325
  • LOCTITE 325
  • 105-129-9001
  • A15B59D2
  • CKFSG79852
  • 32530
  • 135401
  • 7614A111
  • 32555
Cage Codes:
  • Loctite Corp (CAGE 05972)
  • Honeywell International Inc. (CAGE 70210)
  • Ametek Inc. (CAGE 97424)
  • Carr Supply Company Mcmaster (CAGE 39428)
Identification:
HMIC

Y - Indicates information is in the hazardous materials information resource system (hmirs).

PMIC

A - Item does not contain precious metal.

CRITL

- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Freight Information:
  • NMFC:

    004620 - Adhesives: cements, glues, pastes noi

  • WCC:

    705 - Cement, liquid

  • SHC:

    9 - Other or no special handling required (sh)

  • ADC:

    A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.

  • ACC:

    C - Chemical corps items and all other chemicals not covered in other classificatons. note: when an item has a chemical proper shipp

  • LTL:

    W - Rating variable

  • TCC:

    Z - No special type of cargo code applicable

NSN Management Codes:
  • SOS
    Gsa
  • AAC
    H
  • Quantity per pack
    No qup
  • Unit of Measure
    Bt
  • Shelf Life
    12 mo.
  • Classification Control
    U
  • MGMT_CTL
    Sf9---n
  • Repariability

Questions & Answers:

What are the historical prices recorded for this stock number?
Historical data shows pricing from $108.66 to $181.10..
Does NSN 8040-01-254-0300 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
Department Of The Air Force, Department Of The Navy, General Services Administration, Austria, Singapore, Canada, Germany, and Italy
What is the NIIN of NSN 8040-01-254-0300?
012540300 or 01-254-0300
Does NSN 8040-01-254-0300 require demilitarization?
Yes - ITAR Controlled
What is the most recent solicitation for NSN 8040-01-254-0300?
Solicitation SPE8ES21T3655 for qty 3 on 04/05/2021
When was this national stock number assigned to the federal catalog?
Apr 29, 1987
MSDS

Material Safety

MSDS BNKMV 32530 SPEEDBONDER 325 STRUCTURAL ADHESIVE

Hazards


ld50 lc50 mixture: oral ld50(lab animal): >5000 mg/kg
route of entry inds - inhalation: no
skin: no
ingestion: no
carcinogenicity inds - ntp: no
iarc: yes
osha: no
effects of exposure: may cause irritation of eyes, skin, nose/throat. May cause
dermatitis on prolonged contact in sensitive individuals.

explanation of carcinogenicity: see ingredients
signs and symptions of overexposure: irritation.

medical cond aggravated by exposure: acrylic acid: upper respiratory & lung
diseases, dermatitis.

first aid: ingestion: don't induce vomiting. Keep calm. Inhalation: remove to
fresh air. Skin: wash w/soap & water. Eyes: flush w/water for 15 mins.

obtain medical attention in all cases.

Chemical Properties


hcc: n1
b.P. Text: >300f
vapor pres: <10 @ 80f
spec gravity: 1.11 @ 80f
voc grams/liter: 344
solubility in water: slight
appearance and odor: yellowish liquid w/sharp, irritating odor.

HAZCOM Label


product id: 32530 speedbonder 325 structural adhesive
cage: 7k128
company name: loctite corp
street: 705 n mt rd
city: newington ct
zipcode: 06111
health emergency phone: 203-278-1280
label required ind: y
date of label review: 06/12/1992
status code: c
label date: 06/12/1992
origination code: f
chronic hazard ind: y
eye protection ind: yes
skin protection ind: yes
signal word: warning
health hazard: slight
contact hazard: slight
fire hazard: moderate

Reactivity

Hazard and precautions: skin: dermatitis eyes: irritation. Carcinogen
(saccharin). suspected human carcinogen.

Proper Disposal


spill release procedures: soak up in an inert absorbent. Store in a partly
filled, closed container until disposal.

waste disposal methods: incinerate iaw/federal, state & local regulations.

handling and storage precautions: store <100f. Avoid prolonged skin contact.

keep away from eyes. Avoid prolonged breathing of vapors.

MSDS BZFZN 32530 SPEEDBONDER 325 STRUCTURAL ADHESIVE

Hazards


ld50 lc50 mixture: oral ld50(lab animal): >5000 mg/kg
route of entry inds - inhalation: yes
skin: no
ingestion: no
carcinogenicity inds - ntp: no
iarc: no
osha: no
effects of exposure: liquid will cause irritation of the eyes & skin.

vapors may cause irritation of eyes, nose & throat. May cause dermatitis
in sensitive individuals.

explanation of carcinogenicity: none
signs and symptions of overexposure: irritation.

medical cond aggravated by exposure: acrylic acid: upper respiratory & lung
diseases, dermatitis.

first aid: ingestion: don't induce vomiting. Keep calm. Inhalation: remove to
fresh air. Skin: wash w/soap & water. Eyes: flush w/water for 15 mins.

obtain medical attention in all cases.

Chemical Properties


hcc: n1
b.P. Text: >300f
vapor pres: <10
spec gravity: 1.11
voc grams/liter: 344
solubility in water: slight
appearance and odor: yellowish liquid w/sharp, irritating odor.

HAZCOM Label


product id: 32530 speedbonder 325 structural adhesive
cage: 7k128
company name: loctite corp
street: 705 n mt rd
city: newington ct
zipcode: 06111
health emergency phone: 203-571-5100
label required ind: y
date of label review: 12/16/1998
status code: c
label date: 12/16/1998
origination code: g
hazard and precautions: liquid will cause irritation of the eyes & skin.

vapors may cause irritation of eyes, nose & throat. May cause dermatitis
in sensitive individuals.

irritation.

Reactivity

=======================================================
stability indicator: yes
materials to avoid: none
hazardous decomposition products: fire/thermal: irritating organic vapors.

hazardous polymerization indicator: no

Proper Disposal


spill release procedures: soak up in an inert absorbent. Store in a partly
filled, closed container until disposal.

waste disposal methods: incinerate iaw/federal, state & local regulations.

handling and storage precautions: store <100f. Avoid prolonged skin contact.

keep away from eyes. Avoid prolonged breathing of vapors.

MSDS CHKJP SPEEDBONDER (TM) 325 STRUCTURAL ADHESIVE

Hazards


ld50 lc50 mixture: oral ld50 >5000 mg/kg;dermal >2000
route of entry inds - inhalation: yes
skin: yes
ingestion: yes
carcinogenicity inds - ntp: yes
iarc: yes
osha: no
effects of exposure: eye: irritation. Skin: irritation. Inhal: irritation.

ingest: may be harmful. May cause kidney/liver damage.

explanation of carcinogenicity: saccharin is listed by iarc as possible human
carcinogen.

signs and symptions of overexposure: may cause severe dermatitis on prolonged
contact in sensitive people.

medical cond aggravated by exposure: acrylic acid upper respiratory/lung
disease, dermatitis.

first aid: eye: flush w/water 15 minutes. Get med aid. Skin: wash w/soap &
water. Inhal: get fresh air. Get med aid. Ingest: do not induce vomiting.

keep calm. Get med aid.

Chemical Properties


b.P. Text: >300f,>149c
vapor pres: <10 @ 80f
spec gravity: 1.11 @ 80f
solubility in water: slight
appearance and odor: yellowish liquid, sharp irritating odor

HAZCOM Label


product id: speedbonder (tm) 325 structural adhesive
cage: 05972
company name: loctite corporation
street: 1001 trout brook crossing
city: rocky hill ct
zipcode: 06067-3910
health emergency phone: 860-571-5100
label required ind: y
date of label review: 10/12/1999
status code: a
origination code: g
hazard and precautions: eye: irritation. Skin: irritation. Inhal: irritation.

ingest: may be harmful. May cause kidney/liver damage.

Transportation

=======================================================
responsible party cage: 05972
trans id no: 118565
product id: speedbonder (tm) 325 structural adhesive
msds prepared date: 04/15/1997
review date: 06/18/1998
mfn: 3
multiple kit number: 0
review ind: y
unit of issue: bt
container qty: 0

Reactivity

=======================================================
stability indicator: yes
stability condition to avoid: none
materials to avoid: none
hazardous decomposition products: irritating organic vapors
hazardous polymerization indicator: no
conditions to avoid polymerization: none

Proper Disposal


spill release procedures: maintain adequate vent. Use inert absorbent. Store in
partly filled closed container.

waste disposal methods: incinerate following epa/local regs.

handling and storage precautions: store <100f.

other precautions: avoid prolonged skin contact. Keep away from eyes. Avoid
prolonged breathing vapors.