Worldwide distributor of NSN parts and consumables located in the USA.

Adhesive

NSN: 8040-01-365-0918 | Model: PL10BOND-30
ITAR Registered seal

A substance compounded for binding materials together by surface attachment. It is not used primarily to fill voids or pores or for sealing purposes. Excludes canada balsam; cement, watch jewel; film cement, photographic; gasket cement; and gasket shellac compound.

NSN Properties and Flags
NATO Stock Number
8040-01-365-0918
DEMIL
Yes - ITAR Controlled (Code F)
Criticality Code Justification
Zzzy
Reference Number Differentiating Characteristics
Material will be in accordance with navicp mech; activity hx quality control, manufacturing and testing specifications.

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

NSN 8040-01-365-0918 Datasheet

Supply Class (FSC):
Adhesives
Cross Reference:
  • PL10BOND-30
  • 908-26PC9
Cage Codes:
  • Goodyear Tire and Rubber Co The (CAGE 73842)
  • Huntington Ingalls Incorporated (CAGE 43689)
Identification:
HMIC

Y - Indicates information is in the hazardous materials information resource system (hmirs).

PMIC

A - Item does not contain precious metal.

ADPE

- Represents items with no adp components

CRITL

- The item does not have a nuclear hardened feature but does have other critical featur (s) such as tolerance, fit restrictions or application.

Freight Information:
  • NMFC:

    004620 - Adhesives: cements, glues, pastes noi

  • WCC:

    635 - Chemicals, other than drugs or sundries

  • SHC:

    9 - Other or no special handling required (sh)

  • ADC:

    A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.

  • ACC:

    C - Chemical corps items and all other chemicals not covered in other classificatons. note: when an item has a chemical proper shipp

  • TCC:

    R - Flammable liquids, un class 3 (flammable liquids label)

  • LTL:

    W - Rating variable

NSN Management Codes:
  • SOS
    Nrp
  • AAC
    D
  • Quantity per pack
    1
  • Unit of Measure
    Qt
  • Shelf Life
    12 mo.
  • Classification Control
    7
  • MGMT_CTL
    1hx3blf
  • Repariability
    Medium demand velocity items (consumables)

Questions & Answers:

What are the historical prices recorded for this stock number?
Historical data shows pricing from $226.80 to $378.00..
Does NSN 8040-01-365-0918 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
Department Of The Navy
What is the NIIN of NSN 8040-01-365-0918?
013650918 or 01-365-0918
Does NSN 8040-01-365-0918 require demilitarization?
Yes - ITAR Controlled
What is the most recent solicitation for NSN 8040-01-365-0918?
No solicitations for this NSN.
When was this national stock number assigned to the federal catalog?
Oct 01, 1992
MSDS

Material Safety

MSDS CDXCS PLIOBOND 30

Hazards


ld50 lc50 mixture: none specified by manufacturer.

route of entry inds - inhalation: yes
skin: yes
ingestion: yes
carcinogenicity inds - ntp: yes
iarc: yes
osha: yes
effects of exposure: acute: eyes: causes sev irrit; stinging, tearing, redness,
swell & dmg. Skin: causes irrit; redness, burning, drying, cracking, burns
& dmg. May cause sensit. Can be absorbed in tox amts. Inhal: tox is lo w.

brthg lg amts may be harmful; irrit (nose, throat, resp tract), cns depress
(dizz, drow, weak, fatg,(efts of overexp)
explanation of carcinogenicity: see "lr" version for additional information
(fp n).

signs and symptions of overexposure: hlth haz: naus, hdch, uncon). Ingest: tox is
low. Lg amts may be harmful; cns depress (as in acute inhal). Matl can enter
lungs during swallowing/vomit & cause lung inflamm &/or dmg.

chronic: animal: ing 5: incrs onset of peripheral neuropathy caused by expos to
methl butyl ketone, n-hexane &/or ethyl butyl ketone.

medical cond aggravated by exposure: pre-existing skin disorders, lung
disorders (e.G., asthma-like cndtns), liver, kidney & eye disorders may
be aggravated by exposure to this material.

first aid: skin: remove contam clthg. Flush expos area w/lg amts of water. If
dmgd, seek immed med attn. If not dmgd & symps persist, seek med attn.

launder clthg before reuse. Eyes: immed move individual away fro m expos &
into fresh air. Flush w/waterfor at lst 15 mins while holding eyelids apart;
seek immed med attn. Ingest: do not induce vomit. Matl is aspir haz. If
individual is drowsy/unconscious,

Chemical Properties


hcc: f2
b.P. Text: 175f,79c
vapor pres: 70 @ 20c
vapor density: hvr/air
evaporation rate & reference: slower than ether
appearance and odor: tan colored liquid.

percent volatiles by volume: 68-72

HAZCOM Label


product id: pliobond 30
cage: 34897
company name: ashland chemical co
po box: 2219
city: columbus oh
zipcode: 43216-2219
health emergency phone: 800-274-5263
label required ind: y
date of label review: 06/25/1997
status code: c
label date: 06/25/1997
origination code: g
chronic hazard ind: y
eye protection ind: yes
skin protection ind: yes
signal word: danger
respiratory protection ind: yes
health hazard: severe
contact hazard: severe
fire hazard: severe

Transportation

=======================================================
responsible party cage: 34897
trans id no: 129590
product id: pliobond 30
msds prepared date: 05/06/1994
review date: 07/23/1997
mfn: 1
multiple kit number: 0
review ind: y
unit of issue: pt
container qty: 1

Reactivity

Hazard and precautions: flammable. Acute: eye: severe irritation; stinging,
tearing, redness, swelling and damage. Skin: irritation; redness, burning,
drying, cracking, burns and damage. Sensitization. Inhalation: harmful; irrit
ation, central nervous system depression. Ingestion: central nervous system
depression, aspiration hazard - lung inflammation or damage. Chronic: cancer
hazard. Contains material which is listed as an a nimal lung carcinogen (fp
n). Fetal harm. Liver or kidney effects.

Proper Disposal


spill release procedures: sm spill: elim all sources of ignit such as flares,
flames (incl pilot lights) & elec spks. Absorb liq on vermiculite, floor
absorb/other absorb matl. Lg spill: pers not wearing prot equip should be exc
luded from area of spill until clean-up
neutralizing agent: none specified by manufacturer.

waste disposal methods: small spill: dispose of i/a/w all local, state &
federal regulations. Large spill: destroy by liquid incineration i/a/w
applicable regulations.

handling and storage precautions: none specified by manufacturer.

other precautions: containers of this material may be hazardous when emptied.

since emptied containers retain product residues (vapor, liquid &/or
solid), all hazard precautions given in this msds must be observed.