Worldwide distributor of NSN parts and consumables located in the USA.
An oil primarily prepared for lubrication of aircraft instruments, gyro instruments, electronic equipment, gyros in torpedoes and aerial bombs, and calibrating and measuring instruments.
The last inventory check on this NSN was done on 05/25/2023. Due to rapid changes in inventory this may not be the current stock qty.
Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.
Lubricating oils with or without additives, nesoi
Petroleum oils & oils from bituminous minerals (other than crude), and productds therefrom containing 70% (by wt) or more of these oils, nes
Petroleum products, other
Y - Indicates information is in the hazardous materials information resource system (hmirs).
PMICA - Item does not contain precious metal.
Questions & Answers: |
|
What are the historical prices recorded for this stock number? | |
No pre-dated pricing for this NSN could be found. | |
Does NSN 9150-00-077-3561 have a shelf life? | |
No. There is no shelf life applicable for this NSN. | |
What NATO entities are users of this NSN? | |
Bureau Of Mines | |
What is the NIIN of NSN 9150-00-077-3561? | |
000773561 or 00-077-3561 | |
Does NSN 9150-00-077-3561 require demilitarization? | |
Yes - ITAR Controlled | |
What is the most recent solicitation for NSN 9150-00-077-3561? | |
No solicitations for this NSN. | |
When was this national stock number assigned to the federal catalog? | |
Jan 01, 1963 |
ld50 lc50 mixture: none specified by manufacturer.
route of entry inds - inhalation: yes
skin: no
ingestion: no
carcinogenicity inds - ntp: no
iarc: no
osha: no
effects of exposure: prolonged or repeated skin contact may cause irritation.
product contacting the eyes may cause irritation. Product has low order of
acute oral & dermal toxicity, but minute amounts aspirated into the
lungs during ingestion or vomiting may cause mild to severe pulmonary injury
& possibly death.
explanation of carcinogenicity: not relevant
signs and symptions of overexposure: see health hazards.
medical cond aggravated by exposure: none specified by manufacturer.
first aid: eyes: flush with clean water for 15 minutes or until irritation
subsides. If irritation persists, consult md. Skin: remove any contaminated
clothing & wash skin thoroughly with soap & water. Consult m d if
irritation persists. Inhal: removeto source of fresh air. Ingest: do not
induce vomiting; call md immediately.
b.P. Text: 560f,293c
vapor pres: 0.01 @ 20c
vapor density: >5
spec gravity: 0.88 (h*2o=1)
evaporation rate & reference: nil
solubility in water: negligible (
appearance and odor: clear liquid, yellow color; faint petroleum hydrocarbon
odor.
percent volatiles by volume: nil
product id: lubricating oil, #71042
cage: 08987
company name: honeywell inc
street: 1100 virginia dr
city: fort washington pa
zipcode: 19304
health emergency phone: 215-641-4328
label required ind: y
date of label review: 03/02/1994
status code: c
label date: 03/02/1994
origination code: g
chronic hazard ind: y
eye protection ind: yes
skin protection ind: yes
signal word: caution
respiratory protection ind: yes
health hazard: slight
contact hazard: slight
fire hazard: slight
=======================================================
responsible party cage: 08987
trans id no: 46171
product id: lubricating oil, #71042
msds prepared date: 03/12/1991
review date: 04/01/1994
mfn: 1
multiple kit number: 0
review ind: y
Hazard and precautions: acute: prolonged or repeated skin contact may cause
irritation. Product contacting the eyes may cause irritation. Product has low
order of acute oral & dermal toxicity, but minute amounts aspirated in to
the lungs during ingestion or vomiting may cause mild to severe pulmonary
injury & possibly death. Chronic: none listed by manufacturer.
spill release procedures: clean up with dry oil absorbent material. Keep out of
sewers & streams. Advise appropriate authorities if product has or may
enter sewers, waterways or land areas. Conform with applicable governmental
regulations.
neutralizing agent: none specified by manufacturer.
waste disposal methods: dispose of in accordance with all federal, state and
local regulations. Do not flush to drain or stormsewer.
handling and storage precautions: keep containers closed when not in use. Avoid
contact with strong oxidants.
other precautions: none specified by manufacturer.