Secure Ordering: +1 (757) 528-8028
NationalStockNumber.info
NationalStockNumber.INFO

Worldwide distributor of NSN parts and consumables located in the USA.

Adhesive

NSN: 8040-01-108-6666 | Model: METREGRIP 303

A substance compounded for binding materials together by surface attachment. It is not used primarily to fill voids or pores or for sealing purposes. Excludes canada balsam; cement, watch jewel; film cement, photographic; gasket cement; and gasket shellac compound.

NSN Properties and Flags
NATO Stock Number
8040-01-108-6666
DEMIL
NO
Physical Form
Paste
Quantity Within Each Unit Package
1.000 pounds
Specific Usage Design
For general purpose bonding applications
Features Provided
Separate catalyst
Color
Tan
Material
Plastic epoxy
Supplementary Features
1 pound kit
Recent Solicitations
Solicitation Return by Date Buyer Code Quantity
SPE8ES20T2601 2020-02-18 PEPCE 2 KT
SPE8ES20T1287 2019-12-10 PEPCE 6 KT
SPE8ES20T0652 2019-11-18 PEPCE 1 KT
SPE8ES20T0333 2019-10-22 PEPCE 4 KT
SPE8ES19T8285 2019-09-23 PEPCE 3 KT
SPE8ES19T6804 2019-07-22 PEPCE 1 KT
SPE8ES19T1452 2018-12-03 PEPCE 20 KT
SPE8ES19T1192 2018-11-21 PEPCE 1 KT
SPE8ES19Q0052 2018-10-18 PEPCE 6 KT
SPE8ES19Q0012 2018-10-08 PHPHB 6 KT

Inventory Check

The last inventory check on this NSN was done on 04/18/2024. Due to rapid changes in inventory this may not be the current stock qty.

  • New: 5

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping

NSN 8040-01-108-6666 Datasheet

Supply Class (FSC):
Adhesives
Cross Reference:
  • METREGRIP 303
  • BMS5-72 TY2
  • NMS433-715
  • METREGRIP 303 1LB KT.
Cage Codes:
  • Metachem Resins Corporation (CAGE 18604)
  • The Boeing Company (CAGE 81205)
  • Northrop Grumman Systems Corporation (CAGE 95542)
Replacements:
  • 8040-01-108-6666 replaces 8040-01-118-2079
  • 8040-01-108-6666 replaces 8040-01-154-7009
Identification:
HMIC

Y - Indicates information is in the hazardous materials information resource system (hmirs).

PMIC

A - Item does not contain precious metal.

CRITL

- The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

Freight Information:
  • NMFC:

    004620 - Adhesives: cements, glues, pastes noi

  • WCC:

    705 - Cement, liquid

  • SHC:

    9 - Other or no special handling required (sh)

  • ADC:

    A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.

  • ACC:

    C - Chemical corps items and all other chemicals not covered in other classificatons. note: when an item has a chemical proper shipp

  • LTL:

    W - Rating variable

  • TCC:

    Z - No special type of cargo code applicable

NSN Management Codes:
  • SOS
    Gsa
  • AAC
    V
  • Quantity per pack
    No qup
  • Unit of Measure
    Kt
  • Shelf Life
    6 mo.
  • Classification Control
    U
  • MGMT_CTL
    J2200x-
  • Repariability
    This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item.

Questions & Answers:

What are the historical prices recorded for this stock number?
Historical data shows pricing from $538.97 to $898.29..
Does NSN 8040-01-108-6666 have a shelf life?
No. There is no shelf life applicable for this NSN.
What NATO entities are users of this NSN?
Department Of The Air Force, and General Services Administration
What is the NIIN of NSN 8040-01-108-6666?
011086666 or 01-108-6666
Does NSN 8040-01-108-6666 require demilitarization?
Yes - ITAR Controlled
What is the most recent solicitation for NSN 8040-01-108-6666?
Solicitation SPE8ES20T2601 for qty 2 on 02/13/2020
When was this national stock number assigned to the federal catalog?
Mar 03, 1981
MSDS

Material Safety

MSDS BVVCQ METREGRIP 303LV BASE

Hazards

Routes of entry: inhalation: yes skin: yes ingestion: yes
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: overexposure effects: irritation,
sensitization & dermatitis. Ansi classification 4. No chronic
information found.

explanation of carcinogenicity: manufacturer gave no comments other than
the above references to the three listings.

effects of overexposure: mild skin irritation. Mild eye irritation.

medical cond aggravated by exposure: none known

First Aid

First aid: call a physician. Eye: immediately flush with water at least
15 minutes. Skin: promptly wash throughly with water at least 15
minutes. Inhaled: remove to fresh air. Give oxygen if breathing is
difficult.

Chemical Properties

Hcc: n1
nrc/state lic num: none
boiling pt: b.P. Text: >500f,>260c
melt/freeze pt: m.P/f.P text: no data
vapor pres: no data
vapor density: no data
spec gravity: 1.2
evaporation rate & reference:
solubility in water: negligible
appearance and odor: clear liquid. Slight odor.

Reactivity

Stability indicator/materials to avoid: yes
strong oxidizing agents.

stability condition to avoid: elevated temperatures.

hazardous decomposition products: carbon monoxide, carbon dioxide,
aldehydes.

conditions to avoid polymerization: strong acids or bases in bulk.

Proper Disposal

Waste disposal methods: incineration where permitted under federal,
state & local regulations.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: trade secret under osha 29cfr1910.1200 (composition will be
released in event of a medical emergency.)
fraction by wt: 100%
other rec limits: none recommended

MSDS BVVCR METREGRIP 303LV ACTIVATOR

Hazards

Ld50 lc50 mixture: ld50 (oral rat) is >8 grams/kg
routes of entry: inhalation: yes skin: yes ingestion: yes
reports of carcinogenicity: ntp: no iarc: no osha: no
health hazards acute and chronic: ansi classification 3. Acute dermal
toxicity >8 g/kg (rabbit). Extremely irritating to eyes.

explanation of carcinogenicity: manufacturer gave no comments other than
the above references to the three listings.

effects of overexposure: eye pain, skin rash.

medical cond aggravated by exposure: allergies.

First Aid

First aid: call physician. Inhalrd: remove to fresh air. Oxygen and
artificial respiration if necessary. Ingested: not a likely hazard.

skin: wipe off excess. Rinse skin with 5% acetic acid, scrub with
soap and wat er. Eyes: flush immediately with plenty of water for 15
minutes. See an eye physician.

Chemical Properties

Hcc: n1
nrc/state lic num: none
boiling pt: b.P. Text: decomposes
melt/freeze pt: m.P/f.P text: no data
vapor pres: no data
vapor density: no data
spec gravity: 1.0
evaporation rate & reference: no data
solubility in water: negligible
appearance and odor: tan viscous liquid

Reactivity

Stability indicator/materials to avoid: yes
strong oxidizing agents.

stability condition to avoid: none
hazardous decomposition products: carbon dioxide and/or carbon monoxide,
nitrogen oxides

Proper Disposal

Waste disposal methods: incineration where permitted under federal,
state + local regulations.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: trade secret under osha 29cfr1910.1200 (composition will be
released in event of a medical emergency.)
fraction by wt: 100%
other rec limits: none recommended

MSDS CLPTV METREGRIP 303 BASE

Hazards

Reports of carcinogenicity: ntp: unknown iarc: yes
health hazards acute and chronic: ansi classification 2, possible
irritation and sensitization. This product contains less than 0.2%
of a material which if inhaled is classified by iarc as possibly
carcinogenic to humans. Under normal conditions of intended use as
an adhesive, this ingredient should pose no health hazard as it is
fully encapsulated by the resin. A hazard could exist if the cured
product is machined, drilled, or ot herwise abraded in such a way
that respirable airborne duct particles are created.

explanation of carcinogenicity: contains an ingredient included as 2a:
probably carcinogenic to humans.

effects of overexposure: skin redness, eye pain, allergic reaction.

medical cond aggravated by exposure: allergy, eczema or skin conditions.

First Aid

First aid: inhalation: remove to fresh air. Skin: wash skin with soap
and water.Ingestion: if conscious, give water or milk. Eyes: flush
with water at least 15 minutes.

Chemical Properties

Boiling pt: =260.C, 500.F
vapor pres: less than 0.1.

spec gravity: 1.2
evaporation rate & reference: less than 1.

solubility in water: negligible
appearance and odor: tan paste. No odor

Reactivity

Stability indicator/materials to avoid: yes
strong oxidizers, acids or bases.

hazardous decomposition products: carbon dioxide, carbon monoxide,
aldehydes.

conditions to avoid polymerization: will not occur.

Proper Disposal

Waste disposal methods: incineration where permitted under federal,
state and local regulations.

disclaimer (provided with this information by the compiling agencies):
this information is formulated for use by elements of the department
of defense. the united states of america in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Ingredients List

Ingred name: bisphenol a diglycidyl ether resin
cas: 25068-38-6
code: f
rtecs #: ce6880000

MSDS CLPTW METREGRIP 303 ACTIVATOR

Hazards


route of entry inds - inhalation: yes
skin: yes
iarc: yes
effects of exposure: may cause severe skin irritation. Causes severe eye
irritation or burns. May cause permanent visual impairment. Vapors may
irritate upper respiratory tract. Ingestion may cause gastrointestinal irrita
tion or ulceration. May burns mouth and throat. No chronic exposure or target
organ effects are known. This product contains less than 0.2% of a material
which if inhaled is classified by iarc as poss ibly carcinogenic to humans.

under normal conditions of use as an adhesive. This ingredient should pose no
health hazard as it is fully encapsulated. A hazard could exist in such a way
that respirable airborne dust particles are created.

explanation of carcinogenicity: contains an ingedient (less than 0.2%) included
as 2a: probably carcinogenic to humans.

signs and symptions of overexposure: skin redness, eye pain, allergic reaction.

medical cond aggravated by exposure: allergies.

first aid: call a physician if on skin, remove contaminated clothing. Flush
skin with water fo 15 minutes. Wash with mild soap and water. For persistent
irritation, see a physician. In in eye, immediately flush with water at
least 15 minutes. Hold eyelids open. Fush only. Do not rub eye or wipe with
cotton. Product contains an abrasive. Promptly see an eye physician. If
inhaled promplty remove to fresh air. if not breathing, give artificial
respiration. If breathing is difficult, give oxygen. If swallowed and
conscious, give water or milk to dilute. Do not induce vomiting. If vomiting
occurs, keep head b elow hips. Give fluid again. Have medica

Chemical Properties


spec gravity: 0.97
solubility in water: negligible
appearance and odor: tan paste. Ammoniacal odor

HAZCOM Label


product id: metregrip 303 activator
cage: 68448
company name: mereco division metachem resins corporation
street: 1505 main street
city: west warwick ri
zipcode: 02893-2992
health emergency phone: 401-822-9300
label required ind: y
date of label review: 11/02/2001
status code: a
origination code: g
hazard and precautions: may cause severe skin irritation. Causes severe eye
irritation or burns. May cause permanent visual impairment. Vapors may
irritate upper respiratory tract. Ingestion may cause gastrointestinal irrita
tion or ulceration. May burns mouth and throat. No chronic exposure or target
organ effects are known. This product contains less than 0.2% of a material
which if inhaled is classified by iarc as poss ibly carcinogenic to humans.

under normal conditions of use as an adhesive. This ingredient should pose no
health hazard as it is fully encapsulated. A hazard could exist in such a way
that respirable airborne dust particles are created.

Reactivity

=======================================================
stability indicator: yes
materials to avoid: strong oxidizers.

hazardous decomposition products: carbon dioxide and/or carbon monoxide,
nitrogen oxides.

hazardous polymerization indicator: no
conditions to avoid polymerization: will not occur.

Proper Disposal


spill release procedures: avoid direct contact. Use protective equipment.

recover uncontaminated material for use. Add dry material to absorb residue.

put closable container for disposal. Scrub area with diluted vinegar. Flush
contaminated area with hot water.

waste disposal methods: incineration where permitted under federal, state and
local regulations.

handling and storage precautions: do not leave containers open. Prevent contact
with eyes.Avoid contact with skin and clothing. Avoid prolonged or repeated
inhalation of vapors. Do not take internally.

other precautions: do not transfer to unlabeled container. Do not cut, drill,
grind or weld on empty container.