NSN 01-0355
Patient Thermoregulator
A device composed of one or more control-actuating mechanisms, one or more switchs, and graduated scales or other indicators. It is designed to measure and control temperature in ovens, furnaces, and the like, through perception of a sensing element connected to the control. Excludes:switch, thermostatic(00451) and thermostat, flow control(16516).
automatic patient control system designed to regulate patient temperature by the application of hyperthermia blankets through which temperature controlled air is circulated; 3 modes: high: op temp: 43 deg c; medium: op temp;38 d c; and low: op temp 32 deg c; all +/- 3 deg; operator selectable temp display for either celsius or fahrenheit; with control panel with these features: main power indicator illumiates when connected to power source; system on/standby; overheat indicator; a temp select button to adjust temp; audible alarm to indicate hose disconnect and temp failure to meet desired setting; shall not be affected by operation of other electrical system. unit should be no larger than 33h, 25w, and 28l, cm; weigh no more than 5.2 kg;must easily attach to iv pole or opt rolling stand; easy blanket attachment and positioning with 3 snap fit hose swivels at 3 points; clamp that secures unit to iv pole special features, unit capable of quiet operation no more than 35 db 3 ft fm patient; shall meet iso 9001 standards for leakage current; ul approved 3 power cord and plug suitable for hospital environments; 110-120 vac, 60 hz, 9.5 amp; 100 vac, 50/60 hz, 9.5 amps; 220-240 vac, 50 hz, 4.5 amps device ratings; rugged constuction to handle normal military field setting hazards; carrying case or can fit into field chest no. 6 w/foam inserts; supplied w/all ancillary items and accessories to include as minimum: hose w/3 in. inlet, 2.26 in. outlet, swivel, 6.5 ft lg; high efficiency 0.2 micron filter compatible w/unit-2; biomed testing and repair equip/tools necessary for field maintenance/repair; and includes consumable patient use items: upper body blanket; full body surgical blanket; 2 operator and 2 service manuals general characteristics item description, thermoregulator patient suitable f/hospital environment part name assigned by controlling agency.
NSN 6530-01-487-6868 Datasheet
- (NSN) National Stock Number
- 6530-01-487-6868
- (FSG) Federal Supply Group
- 65 - Medical, Dental, and Veterinary Equipment and Supplies
- (FSC) Federal Supply Classification
- 6530 - Hospital Furniture, Equipment, Utensils and Supplies
- (NIIN) National Item Identification Number
- 01-487-6868
- Requires Demilitarization
- Yes
- (INC) Item Name Code
- 28787
- Date
- Tue, Aug 14, 2001
- Schedule B Code
- 9018908000
- General Characteristics Item Description
- unit capable of quiet operation no more than 35 db 3 ft fm patient; shall meet iso 9001 standards for leakage current; ul approved 3 power cord and plug suitable for hospital environments; 110-120 vac, 60 hz, 9.5 amp; 100 vac, 50/60 hz, 9.5 amps; 220-240 vac, 50 hz, 4.5 amps device ratings; rugged constuction to handle normal military field setting hazards; carrying case or can fit into field chest no. 6 w/foam inserts; supplied w/all ancillary items and accessories to include as minimum: hose w/3 in. inlet, 2.26 in. outlet, swivel, 6.5 ft lg; high efficiency 0.2 micron filter compatible w/unit-2; biomed testing and repair equip/tools necessary for field maintenance/repair; and includes consumable patient use items: upper body blanket; full body surgical blanket; 2 operator and 2 service manuals
- Part Name Assigned By Controlling Agency
- thermoregulator patient suitable f/hospital environment
- Special Features
- automatic patient control system designed to regulate patient temperature by the application of hyperthermia blankets through which temperature controlled air is circulated; 3 modes: high: op temp: 43 deg c; medium: op temp;38 d c; and low: op temp 32 deg c; all +/- 3 deg; operator selectable temp display for either celsius or fahrenheit; with control panel with these features: main power indicator illumiates when connected to power source; system on/standby; overheat indicator; a temp select button to adjust temp; audible alarm to indicate hose disconnect and temp failure to meet desired setting; shall not be affected by operation of other electrical system. unit should be no larger than 33h, 25w, and 28l, cm; weigh no more than 5.2 kg;must easily attach to iv pole or opt rolling stand; easy blanket attachment and positioning with 3 snap fit hose swivels at 3 points; clamp that secures unit to iv pole
Identification
- Demilitarization Code
- A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
- Precious Metals Indicator
- A - Item does not contain precious metal.
- Hazardous Metals Indicator
- N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
- Pseudo Item Name Code
- 0028787
Cross Reference
CAGE Codes
- 64616
-
Defense Medical Standardization BoardU.s./canadian manufacturers
Freight Information
- Air Commodity
- MZ -
- Air Dimension
- A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
- National Motor Freight Class Rating
- W - Rating variable
- Special Handling
- 9 - Other or no special handling required (sh)
- Type of Cargo
- Z - No special type of cargo code applicable
- Uniform Freight Classification Item Number
- 00000
- Water Commodity
- 651 - Instruments, medical and surgical
- National Motor Freight Classification Item Number
- 056590
Schedule B & Trade
- Schedule B
- 9018-90-8000
- Description
- instruments and appliances used in medical, surgical, dental or veterinary sciences, nesoi
- End Use
- 21610 - Medicinal equipment
- Unit of Quantity
- NO
- USDA
- Yes
- (SITC) Standard International Trade Classification
- 87229
- (NAICS) North American Industrial Classification System
- 339112
Questions & Answers
-
What is the FSCG of the NSN 6530-01-487-6868?
The FSCG of the NSN 6530-01-487-6868 is 6530
-
Does the NSN 6530-01-487-6868 have a Schedule B code assigned?
Yes, the Schedule B code is 9018908000
-
Does NSN 6530-01-487-6868 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
-
Does NSN 6530-01-487-6868 contain precious materials?
Item does not contain precious metal.
-
Does NSN 6530-01-487-6868 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
-
When the NSN 6530-01-487-6868 was assigned to the Federal Catalog?
It was assigned 25 years ago, on Tue, Aug 14, 2001
Pricing & Availability
Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.
Stock Checks
-
5999-01-030-681710/14/2026 12:10 PM EDTSquelch Amplifier1 in stock
-
5310-01-316-795010/14/2026 12:10 PM EDTLock Washer4 in stock
-
5310-01-463-314710/14/2026 12:10 PM EDTFlat Washer3,056 in stock
-
5342-01-280-555210/14/2026 12:10 PM EDTSpecial Cap6 in stock
-
5306-01-098-377710/14/2026 12:10 PM EDTMachine Bolt1,851 in stock
-
2995-01-292-446910/14/2026 12:10 PM EDTSpecial Adapter26 in stock
-
5340-01-022-330110/14/2026 12:10 PM EDTFlush Catch4 in stock
-
1240-00-818-447610/14/2026 08:10 AM EDTOptical Instrument Headrest3 in stock
-
3110-00-042-104510/14/2026 08:10 AM EDTAirframe Ball Bearing1,526 in stock
-
5930-00-815-286010/14/2026 08:10 AM EDTThermostatic Switch3 in stock
-
5310-01-124-663110/14/2026 08:10 AM EDTAssembled Washe Self-Locking Nut1,215 in stock
-
5996-00-100-493210/14/2026 08:10 AM EDTAudio Frequency Amplifier3 in stock
-
5930-01-426-071710/14/2026 08:10 AM EDTSensitive Switch2 in stock
-
8030-00-051-401110/14/2026 08:10 AM EDTSealing Compound1 in stock
-
4820-00-289-249910/14/2026 04:10 AM EDTCheck Valve17 in stock
Recent Updates
-
6210-00-008-550610/13/2026 08:10 AM EDTLight LensIn Indoor and Outdoor Electric Lighting Fixtures
-
6210-00-008-550710/13/2026 08:10 AM EDTLight LensIn Indoor and Outdoor Electric Lighting Fixtures
-
6210-00-008-550810/13/2026 08:10 AM EDTLight LensIn Indoor and Outdoor Electric Lighting Fixtures
-
6210-00-008-550410/13/2026 08:10 AM EDTLight LensIn Indoor and Outdoor Electric Lighting Fixtures
-
6210-00-008-550510/13/2026 08:10 AM EDTLight LensIn Indoor and Outdoor Electric Lighting Fixtures
-
1660-00-008-538210/12/2026 08:10 AM EDTHeat Exchanger Valve PistonIn Pressurizing Equipment, Heating and Aircraft Air Conditioning
-
1660-00-008-538310/12/2026 08:10 AM EDTFlat Valve DiaphragmIn Pressurizing Equipment, Heating and Aircraft Air Conditioning
-
4730-00-008-538510/12/2026 08:10 AM EDTPressure Hole PlugIn Hose, Pipe, Tube, Lubrication and Railing Fittings
-
1660-00-008-538610/12/2026 08:10 AM EDTValve Body AssemblyIn Pressurizing Equipment, Heating and Aircraft Air Conditioning
-
1660-00-008-538710/12/2026 08:10 AM EDTCabin Air Valve GuideIn Pressurizing Equipment, Heating and Aircraft Air Conditioning
-
5342-00-007-006710/09/2026 08:10 AM EDTWeapon System Resilient MountIn Weapon System Hardware
-
5330-00-007-007010/09/2026 08:10 AM EDTPacking RetainerIn Packing and Gasket Materials
-
5310-00-007-007610/09/2026 08:10 AM EDTHexagon NutIn Nuts and Washers
-
5310-00-007-007810/09/2026 08:10 AM EDTKey WasherIn Nuts and Washers
-
5935-00-007-075810/09/2026 08:10 AM EDTElectr Receptacle Connector BodyIn Electrical Connectors
Popular Categories
-
FSC 7320Kitchen Equipment and Appliances
-
FSC 4310Compressors and Vacuum Pumps
-
FSC 8915Fruits and Vegetables
-
FSC 6635Physical Properties Testing and Inspection
-
FSC 5895Miscellaneous Communication Equipment
-
FSC 8457Jewelry
-
FSC 8020Paint and Artists' Brushes
-
FSC 1265Except Airborne Fire Control Transmitting and Receiving Equipment
-
FSC 9525Nonferrous Base Metal Nonelectrical Wire
-
FSC 3630Clay and Concrete Products Industries Machinery
-
FSC 7644Charts and Geodetic Products Digital Maps
-
FSC 1120Nuclear Depth Charges
-
FSC 3040Miscellaneous Power Transmission Equipment
-
FSC 3210Sawmill and Planing Mill Machinery
-
FSC 5815Teletype and Facsimile Equipment