Patient Thermoregulator

A device composed of one or more control-actuating mechanisms, one or more switchs, and graduated scales or other indicators. It is designed to measure and control temperature in ovens, furnaces, and the like, through perception of a sensing element connected to the control. Excludes:switch, thermostatic(00451) and thermostat, flow control(16516).

thermoregulator patient suitable f/hospital environment part name assigned by controlling agency, automatic patient control system designed to regulate patient temperature by the application of hyperthermia blankets through which temperature controlled air is circulated; 3 modes: high: op temp: 43 deg c; medium: op temp;38 d c; and low: op temp 32 deg c; all +/- 3 deg; operator selectable temp display for either celsius or fahrenheit; with control panel with these features: main power indicator illumiates when connected to power source; system on/standby; overheat indicator; a temp select button to adjust temp; audible alarm to indicate hose disconnect and temp failure to meet desired setting; shall not be affected by operation of other electrical system. unit should be no larger than 33h, 25w, and 28l, cm; weigh no more than 5.2 kg;must easily attach to iv pole or opt rolling stand; easy blanket attachment and positioning with 3 snap fit hose swivels at 3 points; clamp that secures unit to iv pole special features, unit capable of quiet operation no more than 35 db 3 ft fm patient; shall meet iso 9001 standards for leakage current; ul approved 3 power cord and plug suitable for hospital environments; 110-120 vac, 60 hz, 9.5 amp; 100 vac, 50/60 hz, 9.5 amps; 220-240 vac, 50 hz, 4.5 amps device ratings; rugged constuction to handle normal military field setting hazards; carrying case or can fit into field chest no. 6 w/foam inserts; supplied w/all ancillary items and accessories to include as minimum: hose w/3 in. inlet, 2.26 in. outlet, swivel, 6.5 ft lg; high efficiency 0.2 micron filter compatible w/unit-2; biomed testing and repair equip/tools necessary for field maintenance/repair; and includes consumable patient use items: upper body blanket; full body surgical blanket; 2 operator and 2 service manuals general characteristics item description.

NSN 6530-01-487-6868 Datasheet

(NSN) National Stock Number
6530-01-487-6868
(NIIN) National Item Identification Number
01-487-6868
Requires Demilitarization
Yes
(INC) Item Name Code
28787
Date
Tue, Aug 14, 2001
Schedule B Code
9018908000
General Characteristics Item Description
unit capable of quiet operation no more than 35 db 3 ft fm patient; shall meet iso 9001 standards for leakage current; ul approved 3 power cord and plug suitable for hospital environments; 110-120 vac, 60 hz, 9.5 amp; 100 vac, 50/60 hz, 9.5 amps; 220-240 vac, 50 hz, 4.5 amps device ratings; rugged constuction to handle normal military field setting hazards; carrying case or can fit into field chest no. 6 w/foam inserts; supplied w/all ancillary items and accessories to include as minimum: hose w/3 in. inlet, 2.26 in. outlet, swivel, 6.5 ft lg; high efficiency 0.2 micron filter compatible w/unit-2; biomed testing and repair equip/tools necessary for field maintenance/repair; and includes consumable patient use items: upper body blanket; full body surgical blanket; 2 operator and 2 service manuals
Part Name Assigned By Controlling Agency
thermoregulator patient suitable f/hospital environment
Special Features
automatic patient control system designed to regulate patient temperature by the application of hyperthermia blankets through which temperature controlled air is circulated; 3 modes: high: op temp: 43 deg c; medium: op temp;38 d c; and low: op temp 32 deg c; all +/- 3 deg; operator selectable temp display for either celsius or fahrenheit; with control panel with these features: main power indicator illumiates when connected to power source; system on/standby; overheat indicator; a temp select button to adjust temp; audible alarm to indicate hose disconnect and temp failure to meet desired setting; shall not be affected by operation of other electrical system. unit should be no larger than 33h, 25w, and 28l, cm; weigh no more than 5.2 kg;must easily attach to iv pole or opt rolling stand; easy blanket attachment and positioning with 3 snap fit hose swivels at 3 points; clamp that secures unit to iv pole

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Pseudo Item Name Code
0028787

Cross Reference

CAGE Codes

64616
Defense Medical Standardization Board
U.s./canadian manufacturers

Freight Information

Air Commodity
MZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
00000
Water Commodity
651 - Instruments, medical and surgical
National Motor Freight Classification Item Number
056590

Schedule B & Trade

Schedule B
9018-90-8000
Description
instruments and appliances used in medical, surgical, dental or veterinary sciences, nesoi
End Use
21610 - Medicinal equipment
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
87229
(NAICS) North American Industrial Classification System
339112

Questions & Answers

  1. What is the FSCG of the NSN 6530-01-487-6868?

    The FSCG of the NSN 6530-01-487-6868 is 6530

  2. Does the NSN 6530-01-487-6868 have a Schedule B code assigned?

    Yes, the Schedule B code is 9018908000

  3. Does NSN 6530-01-487-6868 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 6530-01-487-6868 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 6530-01-487-6868 contain hazardous materials?

    Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

  6. When the NSN 6530-01-487-6868 was assigned to the Federal Catalog?

    It was assigned 25 years ago, on Tue, Aug 14, 2001

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 1 day ago
View History