1. Home /
  2. FSC NSN Catalog /
  3. Circuit Breakers /
  4. 016367-2

NSN 016367-2

Circuit Breaker

A definite continuous length of cable,special purpose,electrical, having one or more ends processed or terminated in fittings which provide for connectionn to other items. For items which the rated working is 300 volts or more, see: cable assembly,power,electrical. Excludes items having branches or forks. Excludes: lead,test and cable and conduit assembly,electrical.

magnetic blowout arc quenching method, at each pole actuator position designation, 5.844 inches nominal body length, trip-reset actuator function, 2.609 inches nominal body height.

NSN 5925-01-239-2040 Datasheet

(NSN) National Stock Number
5925-01-239-2040
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
01-239-2040
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Tue, Aug 26, 1986
Schedule B Code
8536200040
Actuator Function
trip-reset
Actuator Position Designation
at each pole
Arc Quenching Method
magnetic blowout
Body Height
2.609 inches nominal
Body Length
5.844 inches nominal
Body Style
multipole-multiple actuator type
Body Width
2.064 inches nominal
Boss Height
0.218 inches nominal
Center To Center Distance Between Terminals Parallel To Length
3.546 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.032 inches nominal
Circuit Protection Type
overcurrent all locations
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.032 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
External Actuator Linkage Arrangement
one and two linked
Fragility Factor
moderately rugged
Frequency In Hertz
50.0 or 60.0 all locations
Inclosure Protection Type For Which Designed
dustproof
Internal Trip Release Configuration
series trip all locations
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
2 toggle
Material
plastic case
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
Mounting Facility Type And Quantity
4 threaded hole(s) and 4 slot
Mounting Slot Width
0.164 inches nominal
Nominal Thread Size
0.138 inches
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
Pole Quantity
2
Reset Method
manual
Special Handling Feature
magnetic
Storage Type
general purpose warehouse
Terminal Type And Quantity
4 screw
Thread Quantity Per Inch
32
Thread Series Designator
unified national coarse (unc)
Trip Release Characteristic
time delay all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct and 100.000 maximum at 200 pct all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

1FP59
Ikon Systems Inc
U.s./canadian manufacturers
81541
Sensata Technologies Maryland, Inc
Non-manufacturers
01365
Marine Corps Systems Command Div Marine Corps Systems Command Technical Data Repository Customer Service
Government departments or units, including military organizations
1W134
Eaton Corp Aerospace Commercial Controls Div
Non-manufacturers
74193
Eaton Corp Heinemann Products Commercial Controls Div
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-01-239-2040?

    The FSCG of the NSN 5925-01-239-2040 is 5925

  2. Does the NSN 5925-01-239-2040 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-01-239-2040 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-01-239-2040 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-01-239-2040 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-01-239-2040 was assigned to the Federal Catalog?

    It was assigned 40 years ago, on Tue, Aug 26, 1986

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.